BS PD IEC TR 61282-14-2016 Fibre optic communication system design guides Determination of the uncertainties of attenuation measurements in fibre plants《光纤通信系统设计指南 纤维植物中衰减测量不确定度的测定.pdf
《BS PD IEC TR 61282-14-2016 Fibre optic communication system design guides Determination of the uncertainties of attenuation measurements in fibre plants《光纤通信系统设计指南 纤维植物中衰减测量不确定度的测定.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TR 61282-14-2016 Fibre optic communication system design guides Determination of the uncertainties of attenuation measurements in fibre plants《光纤通信系统设计指南 纤维植物中衰减测量不确定度的测定.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、Fibre optic communication system design guidesPart 14: Determination of the uncertainties of attenuation measurements in fibre plantsPD IEC/TR 61282-14:2016Incorporating corrigendum April 2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordT h i s P
2、u b l i s h e d D o c u m e n t i s t h e U K i m p l e m e n t a t i o n o f I E C / T R61282-14:2016, incorporating corrigendum April 2016.The UK participation in its preparation was entrusted by TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/3, Fibre optic systems and active devi
3、ces.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI
4、Standards Limited 2016ISBN 978 0 580 94415 4ICS 33.180.01Compliance with a British Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 31 January 2016.Amendments/corrigenda issued since publi
5、cationDate Text affectedPUBLISHED DOCUMENTPD IEC/TR 61282-14:201631 May 2016 Implementation of IEC corrigendum April 2016: Table C.1 updatedIEC TR 61282-14 Edition 1.0 2016-01 TECHNICAL REPORT Fibre optic communication system design guides Part 14: Determination of the uncertainties of attenuation m
6、easurements in fibre plants INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 33.180.01 ISBN 978-2-8322-3111-1 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. colourinsidePD IEC/TR 61282-14:2016 2
7、 IEC TR 61282-14:2016 IEC 2016 CONTENTS FOREWORD . 5 INTRODUCTION . 7 1 Scope 8 2 Normative references 8 3 Terms, definitions and abbreviations . 8 3.1 Terms and definitions 8 3.2 Abbreviations 10 4 Overview of uncertainty . 10 4.1 What is uncertainty? . 10 4.2 Origin of uncertainties . 10 4.3 What
8、may not be considered as uncertainty? 10 5 Fibre cabling attenuation measurement . 11 5.1 Measurement methods 11 5.2 Sources of uncertainty to be considered . 11 5.2.1 Analysis . 11 5.2.2 Uncertainties due to the environment . 14 5.2.3 Uncertainties due to operator skills 14 5.2.4 Uncertainties due
9、to measurement methods 14 5.2.5 Uncertainties due to measuring instruments 14 5.2.6 Uncertainties due to the setup . 16 5.2.7 Uncertainties due to cabling. 16 6 Uncertainties estimation 17 6.1 Measurement model 17 6.2 Accumulation of uncertainties . 18 7 General representation of the equation using
10、sensitivity coefficients 19 8 Calculation 22 8.1 Combined standard uncertainty . 22 8.2 Expanded uncertainty . 22 8.3 Determination of the coverage factor k 22 8.3.1 General approach 22 8.3.2 Discussion . 22 8.3.3 Typical values of degree of freedom 23 Annex A (normative) Mathematical basis . 24 A.1
11、 General . 24 A.2 Type A evaluation of uncertainty . 24 A.3 Type B evaluation of uncertainty . 24 A.4 Determining the combined standard uncertainty 25 A.5 Reporting 26 Annex B (informative) Measurement methods 27 B.1 Measurement methods as per IEC 61280-4-1 and 61280-4-2 27 B.1.1 General . 27 B.1.2
12、Measurement configuration 27 B.1.3 One-cord reference configuration 27 B.1.4 Two-cord reference configuration 28 B.1.5 Three-cord reference configuration 28 PD IEC/TR 61282-14:2016IEC TR 61282-14:2016 IEC 2016 3 B.2 Measurement methods as per ISO/IEC 14763-3:2014 . 28 B.2.1 General . 28 B.2.2 Channe
13、ls . 29 B.2.3 Links 30 Annex C (normative) Uncertainties evaluation 31 C.1 Type A uncertainties . 31 C.1.1 General . 31 C.1.2 Evaluation of optical source instability and associated uncertainties 31 C.2 Type B uncertainties . 31 C.2.1 General . 31 C.2.2 Evaluation of the power meter noise 31 C.2.3 E
14、lements to be considered for power meter stability analysis . 32 C.2.4 Evaluation of the centre wavelength dependence 32 C.2.5 Spectral width dependence 34 C.2.6 Evaluation of the uncertainties due to MM launch conditions . 34 C.2.7 Evaluation of the PDL 35 C.2.8 Uncertainty of absolute power measur
15、ement . 36 Annex D (normative) Typical values of uncertainties 37 Annex E (informative) Linear to dB scale conversion of uncertainties . 38 E.1 Definition of decibel 38 E.2 Conversion of relative uncertainties 38 Bibliography 39 Figure 1 Fish bone analysis . 13 Figure 2 Measurement model . 17 Figure
16、 B.1 Measurement configuration . 27 Figure B.2 One-cord reference measurement . 27 Figure B.3 Two-cord reference measurement . 28 Figure B.4 Three-cord reference measurement 28 Figure B.5 Measurement on channel 29 Figure B.6 Channel reference measurement 29 Figure B.7 Link measurement configuration
17、. 30 Figure B.8 Link reference measurement . 30 Figure C.1 Typical spectral response of a fibre 33 Figure C.2 Uncertainties due to the launch conditions for a given loss . 35 Table 1 Source of uncertainty (raw list) 11 Table 2 Uncertainties due to measuring instruments 15 Table 3 Uncertainties due t
18、o the setup . 16 Table 4 Uncertainties due to cabling 16 Table 5 Sensitivity coefficients for IEC 61280-4-1 and IEC 61280-4-2 methods 20 Table 6 Sensitivity coefficients for ISO/IEC 14763-3:2014 methods 21 Table 7 Values of k95for different values of n 23 Table 8 Typical values of ni. 23 Table C.1 S
19、pectral attenuation coefficients 33 PD IEC/TR 61282-14:2016 4 IEC TR 61282-14:2016 IEC 2016 Table C.2 Sensitivity coefficients . 33 Table D.1 Typical values of uncertainties . 37 PD IEC/TR 61282-14:2016IEC TR 61282-14:2016 IEC 2016 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ FIBRE OPTIC COMMUNICAT
20、ION SYSTEM DESIGN GUIDES Part 14: Determination of the uncertainties of attenuation measurements in fibre plants FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committee
21、s). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available
22、Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organiza
23、tions liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matt
24、ers express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC Nationa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTR61282142016FIBREOPTICCOMMUNICATIONSYSTEMDESIGNGUIDESDETERMINATIONOFTHEUNCERTAINTIESOFATTENUATIONMEASUREMENTSINFIBREPLANTS

链接地址:http://www.mydoc123.com/p-588907.html