BS PD CLC TR 50627-2015 Study Report on Electromagnetic Interference between Electrical Equipment Systems in the Frequency Range Below 150 kHz《150 kHz以下频率范围内电气设备 系统间电磁干扰的研究报告》.pdf
《BS PD CLC TR 50627-2015 Study Report on Electromagnetic Interference between Electrical Equipment Systems in the Frequency Range Below 150 kHz《150 kHz以下频率范围内电气设备 系统间电磁干扰的研究报告》.pdf》由会员分享,可在线阅读,更多相关《BS PD CLC TR 50627-2015 Study Report on Electromagnetic Interference between Electrical Equipment Systems in the Frequency Range Below 150 kHz《150 kHz以下频率范围内电气设备 系统间电磁干扰的研究报告》.pdf(88页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationStudy Report on ElectromagneticInterference between ElectricalEquipment/Systems in theFrequency Range Below 150 kHzPD CLC/TR 50627:2015National forewordThis Published Document is the UK implementation of CLC/TR50627:2015.The UK participation in its preparation was entrusted
2、to TechnicalCommittee PEL/205, Mains signalling.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Stan
3、dards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 85332 6ICS 33.100.01Compliance with a British Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 31 December 2015
4、.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CLC/TR 50627:2015TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50627 November 2015 ICS 33.100.01 English Version Study Report on Electromagnetic Interference between Electrical Equipment/Systems in
5、the Frequency Range Below 150 kHz Rapport dtude sur les perturbations lectromagntiques entre les quipements / systmes lectriques entre eux dans la plage des frquences infrieure 150 kHZ Studienbericht ber elektromagnetische Interferenz zwischen elektrische Betriebsmittel/Systeme im Frequenzbereich un
6、ter 150 kHz This Technical Report was approved by CENELEC on 2015-11-02. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary
7、, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique
8、Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TR 50627:2015 EPD CLC/TR 50627:2015CLC/TR 50627:2015 (E) 2 Conte
9、nts Page European foreword 4 Introduction 5 1 Scope 6 2 General 6 3 The frequency range from 2 kHz to 150 kHz . 8 3.1 Challenges in terms of EMI . 8 3.2 Frequency utilization . 10 3.3 The impact of voltage / current shapes . 12 3.4 Interaction of equipment . 16 4 Emissions, measurement and test resu
10、lts 16 4.1 General 16 4.2 Noise measured in a block of flats 17 4.3 Lighting equipment . 17 4.3.1 General 17 4.3.2 Compact lamps 17 4.3.3 Fluorescent lamps . 18 4.3.4 LEDs 19 4.4 Portable mains powered tools 20 4.5.1 General 21 4.5.2 Austrian lab tests on inverters . 22 4.5.3 Active Infeed Converter
11、s 22 4.5.4 PV inverters 24 4.5.5 Italian lab and field measurements 25 4.5.6 Power electronics in an Intelligent Distribution Station 27 4.6 Power supplies. 28 4.6.1 General 28 4.6.2 Power supply with PLC signal on DC side 28 4.6.3 Power supply of a TV receiver 28 4.6.5 Power supplies in communicati
12、on technology 29 4.7 Other equipment Rectifier in a cell tower . 31 5 EMI cases, measurement and test results 32 5.1 General 32 5.2 EMI due to conducted emissions . 33 5.2.1 EMI to lighting equipment . 33 5.2.2 EMI to electricity meters . 33 5.2.3 EMI to mains communicating systems (MCS) 34 5.2.4 EM
13、I to medical equipment 50 6 Standardization for the frequency range 2 kHz to 150 kHz. Conformity and time . 57 6.1 Standardization situation 57 6.2 Conformity and time 62 7 Options for improved safeguarding EMC . 62 7.1 For equipment / systems in general 62 7.1.1 Filter application 62 7.1.2 Move fro
14、m PLC to RF 63 7.1.3 Frequency allocation management 63 7.1.4 Move to broadband lines 64 7.1.5 Notching on transmitter side vs. selectivity on receiver side . 65 7.2 For PLC in particular Move to higher frequencies. 67 8 Conclusions . 69 PD CLC/TR 50627:2015CLC/TR 50627:2015 (E) 3 9 Recommendations
15、. 74 Annex A (informative) Acronyms and abbreviations . 77 Bibliography . 80 PD CLC/TR 50627:2015CLC/TR 50627:2015 (E) 4 European foreword This document (CLC/TR 50627:2015) has been prepared by CLC/SC 205A “Mains communicating systems“. Attention is drawn to the possibility that some of the elements
16、 of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association. This Technical R
17、eport provides useful information for standards related to the following European Mandate(s): M/441, M/490. This Technical Report is based on the Study Report “Electromagnetic Interference between Electrical Equipment / Systems in the Frequency Range below 150 kHz” of SC 205A (SC 205A/Sec0339/R:Apri
18、l 2013) (second edition) 1b, with some update according to the developments that have taken place since. PD CLC/TR 50627:2015CLC/TR 50627:2015 (E) 5 Introduction In April 2010, CLC/SC 205A1)published their first Study Report on “Electromagnetic Interference between Electrical Equipment in the Freque
19、ncy Range below 150 kHz” 1a. Related studies had been made and information gathered due to first cases of EM interference, with Touch-dimmer lamps (TDLs) as an EMI victim, an inverter as an EMI source, and automated meter reading systems using powerline communication (AMR-PLC) figuring as EMI victim
20、s as well as sources. Following this first CLC/SC 205A Study Report, its second edition 1b and, based on it, this Technical Report aims at: a) highlighting the broad relevance of recognized electromagnetic interference for safeguarding EMC also in the frequency range 2 kHz 150 kHz; b) extending know
21、ledge about: 1) EMI cases having been observed between electrical equipment in the frequency range 2 kHz to 150 kHz, with an emphasis on interference between: i) electrical equipment and its non-intentional emissions (NIE); ii) mains communicating systems (MCS) using (powerline communication) PLC te
22、chnology with intentional signal injection for the transmission of information over the electricity supply network; 2) different mechanisms causing interference to electrical equipment due to non-intentional or intentional voltage/current components in the considered frequency range; as a basis for
23、evaluating the need for closing the recognized gap in standardization as highlighted in the first edition, and considering the recent developments; that: c) without evaluating certain types of electrical equipment concerning applied technology or priority; d) and with regard to: 1) problems having o
24、ccurred with operational equipment of distribution network operators (DNOs), in particular related to smart metering and smart grids control and monitoring equipment; 2) complaints by network users to deliverers and subsequently by deliverers to DNOs or by network users directly to their DNO, about
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCLCTR506272015STUDYREPORTONELECTROMAGNETICINTERFERENCEBETWEENELECTRICALEQUIPMENTSYSTEMSINTHEFREQUENCYRANGEBELOW150KHZ150KHZ

链接地址:http://www.mydoc123.com/p-588863.html