BS PD CEN TR 14819-2-2005 Safety recommendations for cableway installations designed to carry npersons - Prevention and fight against fire - Part 2 Other funicular railways and oth.pdf
《BS PD CEN TR 14819-2-2005 Safety recommendations for cableway installations designed to carry npersons - Prevention and fight against fire - Part 2 Other funicular railways and oth.pdf》由会员分享,可在线阅读,更多相关《BS PD CEN TR 14819-2-2005 Safety recommendations for cableway installations designed to carry npersons - Prevention and fight against fire - Part 2 Other funicular railways and oth.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、PUBLISHED DOCUMENT PD CEN/TR 14819-2:2005 Safety recommendations for cableway installations designed to carry persons Prevention and fight against fire Part 2: Other funicular railways and other installations ICS 13.220.20; 45.100 PD CEN/TR 14819-2:2005 This Published Document was published under th
2、e authority of the Standards Policy and Strategy Committee on 15 December 2005 BSI 15 December 2005 ISBN 0 580 47384 8 National foreword This Published Document is the official English language version of CEN/TR 14819-2:2005. The UK participation in its preparation was entrusted to Technical Committ
3、ee MCE/20, Aerial ropeways, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European deve
4、lopments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue unde
5、r the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct appl
6、ication. Compliance with a Published Document does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the CEN/TR title page, pages 2 to 24, an inside back cover and a back cover. The BSI copyright notice displayed in t
7、his document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsTECHNICALREPORT RAPPORTTECHNIQUE TECHNISCHERBERICHT CEN/TR148192 November2005 ICS13.220.20;45.100 EnglishVersion Safetyrecommendationsforcablewayinstallationsdesignedto carrypersonsPre
8、ventionandfightagainstfirePart2:Other funicularrailwaysandotherinstallations Recommandationsdescuritpourlesinstallations cblestransportantdespersonnesPrventionetlutte contrelesincendiesPartie2:Autresfuniculaireset autresinstallations SicherheitsempfehlungenfrSeilbahnenfrden PersonenverkehrBrandverht
9、ungundbekmpfungTeil 2:AndereStandseilundSeilbahnen ThisTechnicalReportwasapprovedbyCENon29August2005.IthasbeendrawnupbytheTechnicalCommitteeCEN/TC242. CENmembersarethenationalstandardsbodiesofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France, Germany,Greece,Hungary,Iceland,Ireland,
10、Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2005CEN Allrightsofexplo
11、itationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.CEN/TR148192:2005:ECEN/TR 14819-2:2005 2 Contents Page Foreword .4 Introduction.5 1 Scope6 2 Normative references.6 3 Terms and definitions 7 4 General recommendations.8 4.1 Application of this technical report .8 4.2 Safet
12、y principles.8 4.2.1 General8 4.2.2 Hazard scenarios8 4.2.3 Safety measures.8 5 Basic recommendations 9 6 Recommendations concerning fire prevention and firefighting in carriers.10 6.1 Materials .10 6.2 Electrical cabinets10 6.3 Cabling outside the electrical cabinets and lighting.11 6.4 Batteries11
13、 6.5 Battery chargers.11 6.6 Video equipment (camera, monitor) 11 6.7 Heating, air conditioning11 6.8 Electrical components outside cabinets which are energized during travel (dynamos, alternators, motors)11 6.9 Pantographs .12 6.10 Rail brake Retarder12 6.11 Hydraulic power plants and circuits Pres
14、sure vessels Refrigerants .12 6.12 Prohibition of smoking, open fires and the transportation of flammable materials12 6.13 Extinguishers and other means of firefighting .12 6.14 Capacity of carriers 13 6.15 Recovery measures in the event of a fire on board a carrier .13 6.16 Emergency exits from car
15、riers 13 7 Recommendations concerning fire prevention and firefighting in the area of the line.13 7.1 Rails and overhead catenaries supplying auxiliary electrical power to carriers.13 7.2 Transmission of electrical power along the track or supported by line support structures.14 7.3 Remote communica
16、tion cable between carrier and control point .14 7.4 Transportation of flammable liquid along the funicular railway track .14 7.5 Track or route of line14 8 Recommendations concerning fire prevention and firefighting in stations 15 8.1 General15 8.2 Platform materials 15 8.3 Maintenance pit beneath
17、carriers at the platform .16 8.4 Space adjacent to the platforms16 8.5 Transmission of electrical power 16 8.6 Contacts for recharging the carrier batteries16 8.7 Video equipment (camera, monitor) 16 8.8 Dispensing machines for use by passengers and other platform furniture17 8.9 Prohibition of smok
18、ing, open fires and the transportation of flammable materials17 8.10 Extinguishers17 CEN/TR 14819-2:2005 3 8.11 Smoke detection and clearing. 17 9 Recommendations concerning fire prevention and firefighting in the machine room and electrical power system spaces 17 9.1 Prevention 17 9.2 Limitation of
19、 spread of fire 17 10 Recommendations concerning fire prevention and firefighting in electrical supply spaces. 18 11 Recommendations concerning fire prevention and firefighting in the control room . 18 11.1 Civil engineering 18 11.2 Spaces adjacent to the control point 19 11.3 Electrical equipment 1
20、9 11.4 Video monitors 19 11.5 Space heating 19 11.6 Domestic utensils 19 11.7 Furniture 19 11.8 Putting safety devices out of service 19 11.9 Personnel. 20 12 Lightning 20 13 Training of personnel 20 14 Maintenance. 20 Bibliography. 21 4 Foreword This Technical Report (CEN/TR 14819-2:2005) has been
21、prepared by Technical Committee CEN/TC 242 “Safety requirements for passenger transportation by rope”, the secretariat of which is held by AFNOR. CEN/TR 14819 comprises the following parts presented under the general title of Safety recommendations for cableway installations designed to carry person
22、s - Prevention and fight against fire: Part 1: Funicular railways in tunnels Part 2: Other funicular railways and other installations This technical report forms part of the standards programme approved by the CEN Technical Board (CEN/BT) on safety requirements for cableway installations designed to
23、 carry persons: 1 Safety requirements for cableway installations designed to carry persons - Terminology 2 Safety requirements for cableway installations designed to carry persons - General requirements 3 Safety requirements for cableway installations designed to carry persons - Calculations 4 Safet
24、y requirements for cableway installations designed to carry persons - Ropes 5 Safety requirements for cableway installations designed to carry persons - Tensioning devices 6 Safety requirements for cableway installations designed to carry persons - Drive systems and other mechanical equipment 7 Safe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCENTR1481922005SAFETYRECOMMENDATIONSFORCABLEWAYINSTALLATIONSDESIGNEDTOCARRYNPERSONSPREVENTIONANDFIGHTAGAINSTFIREPART2OTHERFUNICULARRAILWAYSANDOTHPDF

链接地址:http://www.mydoc123.com/p-588684.html