BS ISO 3159-2010 Timekeeping instruments - Wrist-chronometers with spring balance oscillator《计时仪器 具有摆轮游丝振荡器的精密手表》.pdf
《BS ISO 3159-2010 Timekeeping instruments - Wrist-chronometers with spring balance oscillator《计时仪器 具有摆轮游丝振荡器的精密手表》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 3159-2010 Timekeeping instruments - Wrist-chronometers with spring balance oscillator《计时仪器 具有摆轮游丝振荡器的精密手表》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BS ISO 3159:2009ICS 39.040.10NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDTimekeepinginstruments Wrist-chronometers withspring balanceoscillatorThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 28 February20
2、10. BSI 2010ISBN 978 0 580 68480 7Amendments/corrigenda issued since publicationDate CommentsBS ISO 3159:2009National forewordThis British Standard is the UK implementation of ISO 3159:2009.The UK participation in its preparation was entrusted to TechnicalCommittee STI/53, Specifications and test me
3、thods for jewellery andhorology.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standar
4、d cannot confer immunityfrom legal obligations.BS ISO 3159:2009Reference numberISO 3159:2009(E)ISO 2009INTERNATIONAL STANDARD ISO3159Second edition2009-12-15Timekeeping instruments Wrist-chronometers with spring balance oscillator Instruments horaires Chronomtres-bracelet oscillateur balancier-spira
5、l BS ISO 3159:2009ISO 3159:2009(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the
6、editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can
7、 be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat
8、 at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2009 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing fro
9、m either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2009 All rights reservedBS ISO 3159:2009I
10、SO 3159:2009(E) ISO 2009 All rights reserved iiiForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each m
11、ember body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
12、Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards a
13、dopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of p
14、atent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 3159 was prepared by Technical Committee ISO/TC 114, Horology. This second edition cancels and replaces the first edition (ISO 3159:1976) which has been technically revised. BS ISO 3159:2009BS ISO 3159
15、:2009INTERNATIONAL STANDARD ISO 3159:2009(E) ISO 2009 All rights reserved 1Timekeeping instruments Wrist-chronometers with spring balance oscillator 1 Scope This International Standard lays down the definition of the term “chronometer”, describing the categories, the test programme and the acceptabl
16、e minimum requirements for wrist-chronometers. NOTE Wristwatches using a tuning fork oscillator are subjected to these tests pending the availability of separate standards. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated ref
17、erences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3158, Timekeeping instruments Symbolization of control positions 3 Terms and definitions For the purposes of this document, the following terms and d
18、efinitions apply. 3.1 chronometer precision wristwatch regulated for different positions and for various conditions of use NOTE 1 Conformity to the definition of chronometer will be certified by a neutral official authority that checks the watch, or if necessary the movement, and issues an official
19、certificate. NOTE 2 A wristwatch described as a “chronometer” must satisfy the minimum requirements laid down in Clause 7. 4 Categories of wristwatch Wristwatches are divided into two categories dependent on casing diameter or casing-up surface. Category Casing diameter mm Casing-up surface mm21 20
20、314 2 u 20 u 314 BS ISO 3159:2009ISO 3159:2009(E) 2 ISO 2009 All rights reserved5 Definition of criteria 5.1 General The condition of the watch designated by the letter Eiis obtained by subtracting the standard reference time from the time indicated by the watch. The time is observed to within limit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO31592010TIMEKEEPINGINSTRUMENTSWRISTCHRONOMETERSWITHSPRINGBALANCEOSCILLATOR 计时 仪器 具有 摆轮 游丝 振荡器 精密

链接地址:http://www.mydoc123.com/p-587021.html