BS ISO 20481-2008 Coffee and coffee products - Determination of the caffeine content using high performance liquid chromatography (HPLC) - Reference method《咖啡和咖啡制品 使用高效液相色谱测定法(HPLC.pdf
《BS ISO 20481-2008 Coffee and coffee products - Determination of the caffeine content using high performance liquid chromatography (HPLC) - Reference method《咖啡和咖啡制品 使用高效液相色谱测定法(HPLC.pdf》由会员分享,可在线阅读,更多相关《BS ISO 20481-2008 Coffee and coffee products - Determination of the caffeine content using high performance liquid chromatography (HPLC) - Reference method《咖啡和咖啡制品 使用高效液相色谱测定法(HPLC.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS ISO 20481:2008Coffee and coffee products Determination of the caffeine content using high performance liquid chromatography (HPLC) Reference methodICS 67.140.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g
2、54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS ISO 20481:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2008 BSI 2008ISBN 978 0 580 57553 2National forewordThis British Standard is the UK implem
3、entation of ISO 20481:2008. The UK participation in its preparation was entrusted to Technical Committee AW/15, Coffee.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a cont
4、ract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments/corrigenda issued since publicationDate CommentsReference numberISO 20481:2008(E)INTERNATIONAL STANDARD ISO20481First edition2008-05-01Coffee and coffee
5、 products Determination of the caffeine content using high performance liquid chromatography (HPLC) Reference method Caf et drivs du caf Dtermination de la teneur en cafine par chromatographie liquide haute performance (CLHP) Mthode de rfrence BS ISO 20481:2008ii iiiForeword ISO (the International O
6、rganization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been estab
7、lished has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardizat
8、ion. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting
9、. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such p
10、atent rights. ISO 20481 was prepared by Technical Committee ISO/TC 34, Food products, Subcommittee SC 15, Coffee. BS ISO 20481:2008blank1Coffee and coffee products Determination of the caffeine content using high performance liquid chromatography (HPLC) Reference method 1 Scope This International St
11、andard specifies a high performance liquid chromatography (HPLC) method for the determination of the caffeine content of: green coffee; roasted coffee; soluble coffee, regular and decaffeinated; and mixed instant coffee products (e. g. coffee/chicory mix or cappuccino-type coffee drink). 2 Normative
12、 references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 565, Test sieves Metal wire cloth
13、, perforated metal plate and electroformed sheet Nominal sizes of openings ISO 648, Laboratory glassware Single volume pipettes ISO 1042, Laboratory glassware One-mark volumetric flasks ISO 3696, Water for analytical laboratory use Specification and test methods ISO 3726, Instant coffee Determinatio
14、n of loss in mass at 70 C under reduced pressure ISO 6673, Green coffee Determination of loss in mass at 105 C ISO 11817, Roasted ground coffee Determination of moisture content Karl Fischer method (Reference method) 3 Principle Caffeine is extracted from samples with water at 90 C in the presence o
15、f magnesium oxide. After filtration, the caffeine content of the extract is determined by HPLC on a RP-18 column using isocratic elution with UV detection at approximately 272 nm. Wherever appropriate, the caffeine content may be given on dry basis which requires a moisture determination by a suitab
16、le standard method. 4 Reagents Unless otherwise specified, use only reagents of recognized analytical grade, and only water conforming to the requirements of ISO 3696, grade 1. 4.1 Methanol, HPLC grade. BS ISO 20481:20082 4.2 Magnesium oxide (MgO), heavy, high grade1). NOTE The use of MgO is importa
17、nt for the lifetime of the analytical column, especially for green coffee. The amount of MgO used depends on the equipment and on the type of coffee product. The precision data in Annex A were acquired using the procedure described in this International Standard. The appearance of interfering peaks
18、in the chromatogram may be due to improper adsorption. In these cases, subject the MgO used to examination. 4.3 Caffeine (1,3,7-trimethylxanthine; 1,3,7-trimethyl-1H-purine-2,6(3H,7H)-dione; methyltheobromine; C8H10N4O2), pure anhydrous. 4.4 Mobile phase, 24 % volume fraction methanol in water. SAFE
19、TY PRECAUTIONS Wear gloves, eye protection and dispense reagents in a fume cupboard (fume hood). Transfer 240 ml methanol (4.1) to a 1 l one-mark volumetric flask (5.11). Make up to the mark with water, mix and filter through a 0,45 m filter (5.2). NOTE By changing the ratio of methanol to water, th
20、e retention time of caffeine can be adjusted to optimize the HPLC separation on the column used. 4.5 Caffeine standard solutions. 4.5.1 Stock solution, corresponding to 200 mg/l. Weigh (0,200 0,001) g anhydrous caffeine (4.3) into a 1 l one-mark volumetric flask (5.11). Add sufficient warm water to
21、half fill the flask. Swirl to dissolve the caffeine, cool to room temperature, make up to the mark with water and mix. The solution is stable at +4 C for one month. Store in a refrigerator. 4.5.2 Dilute standard solution for regular coffee, corresponding to approximately 40 mg/l. Pipette (5.12) 50 m
22、l of the caffeine standard stock solution (4.5.1) to a 250 ml one-mark volumetric flask (5.11). Make up to the mark with water and mix. Prepare fresh dilute standard solution daily. 4.5.3 Dilute standard solution for decaffeinated coffee, corresponding to approximately 4 mg/l. Pipette (5.12) 5 ml of
23、 the caffeine standard stock solution (4.5.1) to a 250 ml one-mark volumetric flask (5.11). Make up to the mark with water and mix. Prepare fresh dilute standard solution daily. 4.5.4 Calibration plot. The use of a three to five point calibration plot is optional. Recommended concentration range is
24、5 mg/l to 25 mg/l for regular coffee and 0,5 mg/l to 2,5 mg/l for decaffeinated samples. 5 Apparatus Usual laboratory apparatus and, in particular, the following. 5.1 Analytical balance, capable of weighing to an accuracy of 0,1 mg. 5.2 Membrane filter units of pore size 0,45 m, for filtration of mo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO204812008COFFEEANDCOFFEEPRODUCTSDETERMINATIONOFTHECAFFEINECONTENTUSINGHIGHPERFORMANCELIQUIDCHROMATOGRAPHYHPLCREFERENCEMETHOD

链接地址:http://www.mydoc123.com/p-586138.html