BS ISO 18562-2-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for emissions of particulate matter《医疗保健应用中呼吸气体通道的生物相容性评估 颗粒物排放试验》.pdf
《BS ISO 18562-2-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for emissions of particulate matter《医疗保健应用中呼吸气体通道的生物相容性评估 颗粒物排放试验》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 18562-2-2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications Tests for emissions of particulate matter《医疗保健应用中呼吸气体通道的生物相容性评估 颗粒物排放试验》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、BS ISO 18562-2:2017Biocompatibility evaluation of breathing gas pathways in healthcare applicationsPart 2: Tests for emissions of particulate matterBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS ISO 18562-2:2017 BRITISH STANDARDNational forewordThis British Stand
2、ard is the UK implementation of ISO 18562-2:2017. The UK participation in its preparation was entrusted to TechnicalCommittee CH/121/9, Lung Ventilators informative material appearing outside of tables, such as notes, examples and references: in smaller type. Normative text of tables is also in a sm
3、aller type; test specifications: italic type; terms defined in Clause 3 of this document or as noted: small capitals type.In this document, the conjunctive “or” is used as an “inclusive or” so a statement is true if any combination of the conditions is true.The verbal forms used in this document con
4、form to usage described in Annex H of the ISO/IEC Directives, Part 2. For the purposes of this document, the auxiliary verb: “shall” means that compliance with a requirement or a test is mandatory for compliance with this document; “should” means that compliance with a requirement or a test is recom
5、mended but is not mandatory for compliance with this document; “may” is used to describe a permissible way to achieve compliance with a requirement or test.An asterisk (*) as the first character of a title or at the beginning of a paragraph or table title indicates that there is guidance or rational
6、e related to that item in Annex A. ISO 2017 All rights reserved vBS ISO 18562-2:2017ISO 18562-2:2017(E)The attention of Member Bodies is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised ISO publ
7、ication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 3 years from the date of pub
8、lication for equipment newly designed and not earlier than 5 years from the date of publication for equipment already in production.vi ISO 2017 All rights reservedBS ISO 18562-2:2017INTERNATIONAL STANDARD ISO 18562-2:2017(E)Biocompatibility evaluation of breathing gas pathways in healthcare applicat
9、ions Part 2: Tests for emissions of particulate matter1 ScopeThis document specifies tests for the emissions of particulate matter from the gas pathways of a medical device, its parts or accessories, which are intended to provide respiratory care or supply substances via the respiratory tract to a p
10、atient in all environments. The tests of this document are intended to quantify particles from 0,2 m diameter to 10 m diameter that are emitted by the medical device, its parts or accessories into the respirable gas stream. This document establishes acceptance criteria for these tests. This document
11、 does not address nanoparticles. Insufficient data exist to establish exposure limits for particles less than 0,2 m in diameter.NOTE 1 Smaller and larger particles could also present biological hazards, and additional information outside the scope of this document can be needed to meet requirements
12、of some authorities having jurisdiction.This document therefore adopts the same approach as the US Environmental Protection Agency (EPA) in setting limits based solely on particle size and not their chemistry.This document addresses potential contamination of the gas stream arising from the gas path
13、ways, which is then conducted to the patient.This document applies over the expected service life of the medical device in normal use and takes into account the effects of any intended processing or reprocessing.This document does not address biological evaluation of the surfaces of gas pathways tha
14、t are in direct contact with the patient. The requirements for direct contact surfaces are found in the ISO 10993 series.Medical devices, parts or accessories, containing gas pathways that are addressed by this document, include, but are not limited to, ventilators, anaesthesia workstations (includi
15、ng gas mixers), breathing systems, oxygen conserving devices, oxygen concentrators, nebulizers, low-pressure hose assemblies, humidifiers, heat and moisture exchangers, respiratory gas monitors, respiration monitors, masks, mouth pieces, resuscitators, breathing tubes, breathing systems filters, Y-p
16、ieces, and any breathing accessories intended to be used with such devices. The enclosed chamber of an incubator, including the mattress, and the inner surface of an oxygen hood are considered to be gas pathways and are also addressed by this document.This document does not address contamination alr
17、eady present in the gas supplied from the gas sources while medical devices are in normal use.EXAMPLE Contamination arriving at the medical device from gas sources such as medical gas pipeline systems (including the non-return valves in the pipeline outlets), outlets of pressure regulators connected
18、 or integral to a medical gas cylinder, or room air taken into the medical device is not addressed by ISO 18562 (all parts).NOTE 2 This document has been prepared to address the relevant essential principles of safety and performance as indicated in Annex B. ISO 2017 All rights reserved 1BS ISO 1856
19、2-2:2017ISO 18562-2:2017(E)2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the refe
20、renced document (including any amendments) applies.ISO 7396-1:2016, Medical gas pipeline systems Part 1: Pipeline systems for compressed medical gases and vacuumISO 14971:2007, Medical devices Application of risk management to medical devicesISO 18562-1:2017, Biocompatibility evaluation of breathing
21、 gas pathways in healthcare applications Part 1: Evaluation and testing within a risk management process3 Terms and definitionsFor the purposes of this document, the terms and definitions given in ISO 7396-1, ISO 14971, ISO 18562-1 and the following apply.ISO and IEC maintain terminological database
22、s for use in standardization at the following addresses: IEC Electropedia: available at h t t p :/ www .electropedia .org/ ISO Online browsing platform: available at h t t p :/ www .iso .org/ obpNOTE For convenience, an alphabetized index of all defined terms and their sources used in this document
23、is given in Annex C.3.1diameteraerodynamic diameterdiameter of a sphere of density 1 g/cm3with the same terminal velocity due to gravitational force in calm air as the particle of interest, regardless of its geometric size, shape and true density, under the prevailing conditions of temperature, pres
24、sure and relative humiditySOURCE: ISO 7708:1995, 2.2, modified added “of interest, regardless of its geometric size, shape and true density”4 General principles4.1 Type testsThe tests described in this document are type tests. Type tests are performed on the final medical device, a component of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1856222017BIOCOMPATIBILITYEVALUATIONOFBREATHINGGASPATHWAYSINHEALTHCAREAPPLICATIONSTESTSFOREMISSIONSOFPARTICULATEMATTER

链接地址:http://www.mydoc123.com/p-585711.html