BS ISO 17735-2009 Workplace atmospheres - Determination of total isocyanate groups in air using 1-(9-anthracenylmethyl)piperazine (MAP) reagent and liquid chromatography《工作场所空气环境 使.pdf
《BS ISO 17735-2009 Workplace atmospheres - Determination of total isocyanate groups in air using 1-(9-anthracenylmethyl)piperazine (MAP) reagent and liquid chromatography《工作场所空气环境 使.pdf》由会员分享,可在线阅读,更多相关《BS ISO 17735-2009 Workplace atmospheres - Determination of total isocyanate groups in air using 1-(9-anthracenylmethyl)piperazine (MAP) reagent and liquid chromatography《工作场所空气环境 使.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、BS ISO 17735:2009ICS 13.040.30NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDWorkplace atmospheres Determination of total isocyanate groups in air using 1-(9-anthra-cenylmethyl)piperazine (MAP) reagent and liquid chromatographyThis British Standard was publishe
2、d under the authority of the Standards Policy and Strategy Committee on 30 June2009. BSI 2009ISBN 978 0 580 61753 9Amendments/corrigenda issued since publicationDate CommentsBS ISO 17735:2009National forewordThis British Standard is the UK implementation of ISO 17735:2009. The UK participation in it
3、s preparation was entrusted to TechnicalCommittee EH/2/2, Work place atmospheres.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its corr
4、ect application. Compliance with a British Standard cannot confer immunityfrom legal obligations.BS ISO 17735:2009Reference numberISO 17735:2009(E)ISO 2009INTERNATIONAL STANDARD ISO17735First edition2009-03-15Workplace atmospheres Determination of total isocyanate groups in air using 1-(9-anthraceny
5、lmethyl)piperazine (MAP) reagent and liquid chromatography Air des lieux de travail Dosage des groupements isocyanates totaux dans lair par raction avec la 1-(9-anthracnylmthyl)piprazine (MAP) et par chromatographie en phase liquide BS ISO 17735:2009ISO 17735:2009(E) PDF disclaimer This PDF file may
6、 contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the respo
7、nsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creatio
8、n parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2009
9、All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the countr
10、y of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2009 All rights reservedBS ISO 17735:2009ISO 17735:2009(E) ISO 2009 All rights reserved iiiContents Page For
11、eword iv Introduction v 1 Scope . 1 2 Normative references . 1 3 Principle. 1 4 Reagents and materials . 3 5 Apparatus 7 6 Air sampling 9 6.1 Pre-sampling laboratory preparation 9 6.2 Pre-sampling field preparation 10 6.3 Collection of air samples . 10 6.4 Blanks and negative controls 11 6.5 Bulk pr
12、oducts 11 6.6 Shipment of samples 11 6.7 Filter test samples 11 6.8 Impinger test samples 12 7 HPLC analysis . 12 7.1 Instrumental settings 12 7.2 HPLC programme . 12 8 Data handling 14 8.1 Monomer measurement . 14 8.2 Oligomer measurement (total detectable isocyanate) 14 9 Calibration and quality c
13、ontrol 14 9.1 Standard matching solutions 14 9.2 Calibration curves. 15 9.3 Blank tests. 15 9.4 Bulk products 15 9.5 Quality control spikes 15 10 Calculations. 15 10.1 Monomer 15 10.2 Oligomers (total detectable isocyanate). 16 11 Interferences . 16 12 Determination of performance characteristics 17
14、 12.1 Introduction . 17 12.2 Assessment of performance characteristics. 18 Annex A (informative) Performance characteristics. 25 Bibliography . 27 BS ISO 17735:2009ISO 17735:2009(E) iv ISO 2009 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federa
15、tion of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committ
16、ee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance
17、 with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires ap
18、proval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 17735 was prepared by Technical Comm
19、ittee ISO/TC 146, Air quality, Subcommittee SC 2, Workplace atmospheres. BS ISO 17735:2009ISO 17735:2009(E) ISO 2009 All rights reserved vIntroduction This International Standard specifies the use of 1-(9-anthracenylmethyl)piperazine (MAP) to measure monomeric and oligomeric isocyanate species in wo
20、rkplace atmospheres. MAP was designed to improve the reliability of identification of isocyanate species in sample chromatograms and to improve the accuracy of quantification of these species relative to established reagents. The high performance liquid chromatography (HPLC) analysis uses a pH gradi
21、ent to selectively accelerate the elution of MAP derivatives of oligomeric isocyanates that might be unobservable in an isocratic analysis. The performance of MAP has been compared to other reagents used for total isocyanate analysis (Reference 7). MAP has been found to react with phenyl isocyanate
22、(used as a model isocyanate) as fast or faster than other reagents commonly used for isocyanate analysis. The UV response of MAP derivatives is comparable to that of 9-(methylaminomethyl)anthracene (MAMA) derivatives and considerably greater than other commonly used reagents approximately three time
23、s greater than 1-(2-methoxyphenyl)piperazine (1-2MP) derivatives of aromatic isocyanates and 14 times greater than 1-2MP derivatives of aliphatic isocyanates. The compound-to-compound variability of UV response per isocyanate group for MAP derivatives is smaller than the variability of any other com
24、monly used reagent/detector combination (the coefficient of variation is 3,5 % for five model isocyanates). This results in accurate quantification of detectable non-monomeric isocyante species based on a calibration curve generated from analysing standards of monomeric species. The monomeric specie
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO177352009WORKPLACEATMOSPHERESDETERMINATIONOFTOTALISOCYANATEGROUPSINAIRUSING19ANTHRACENYLMETHYLPIPERAZINEMAPREAGENTANDLIQUIDCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-585447.html