BS ISO 17218-2014 Sterile acupuncture needles for single use《一次性无菌针灸针》.pdf
《BS ISO 17218-2014 Sterile acupuncture needles for single use《一次性无菌针灸针》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 17218-2014 Sterile acupuncture needles for single use《一次性无菌针灸针》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS ISO 17218:2014Sterile acupuncture needles forsingle useBS ISO 17218:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 17218:2014. The UK participation in its preparation was entrusted to TechnicalCommittee CH/100, Healthcare and m
2、edical equipment (European and International).A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Stan
3、dards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 78013 4ICS 11.040.25Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2014.Amen
4、dments/corrigenda issued since publicationDate T e x t a f f e c t e dBS ISO 17218:2014 ISO 2014Sterile acupuncture needles for single useAiguilles dacupuncture striles usage uniqueINTERNATIONAL STANDARDISO17218First edition2014-02-01Reference numberISO 17218:2014(E)BS ISO 17218:2014ISO 17218:2014(E
5、)ii ISO 2014 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2014All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an in
6、tranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www.iso.orgPublish
7、ed in SwitzerlandBS ISO 17218:2014ISO 17218:2014(E) ISO 2014 All rights reserved iiiContents PageForeword ivIntroduction v1 Scope . 12 Normative references 13 Terms and definitions . 14 Configuration . 24.1 Acupuncture needle configuration 24.2 Acupuncture needle types . 24.3 Types of needle handles
8、 35 Requirements 55.1 Materials . 55.2 Dimensions . 55.3 Performance requirements 75.4 Sterility assurance 96 Package . 96.1 Primary package 96.2 Secondary package . 107 Labelling .107.1 General 107.2 Primary package . 107.3 Secondary package . 108 Transit and storage .11Annex A (informative) Test m
9、ethods for the intensity and sharpness of the tip of the needle 12Annex B (informative) Test methods for the puncture performance of the tip of the needle16Annex C (informative) Test method for resistance to corrosion .21Bibliography .23BS ISO 17218:2014ISO 17218:2014(E)ForewordISO (the Internationa
10、l Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been es
11、tablished has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardi
12、zation.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance w
13、ith the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any
14、 patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents).Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.
15、For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary informationThe committee responsible fo
16、r this document is ISO/TC 249, Traditional Chinese medicine.iv ISO 2014 All rights reservedBS ISO 17218:2014ISO 17218:2014(E)IntroductionThis International Standard applies to sterile acupuncture needles for single use (specialized for filiform needles) used by professional acupuncturists for acupun
17、cture treatment. Sterile acupuncture needles for single use are sterilized by the manufacturer, and the healthcare professional can open the sealed package and use the needle immediately.In order to encourage innovation, this International Standard does not enforce the combination of the needle diam
18、eter and length. However, considering the clinical usage requirements, the standard provides the specifications for the needle diameter and length.The sharpness and puncture performance of the needle tip are of very important clinical significance. Annex A states the guidelines and the evaluation me
19、thods for the intensity and the sharpness of the needle tip, while Annex B provides two qualitative and quantitative evaluation methods to determine the puncture performance of the needle tip.The qualitative methods to evaluate the puncture performance of needle tip are described in Annex B. The met
20、hods are simple, direct and practical. It makes them especially suitable for routine inspection and for cross-comparison of the acupuncture needles clinical applications. They also play a very important role in the enhancement of the quality of the needle tip. The methods to evaluate the puncture pe
21、rformance of the needle tip can be used to further evaluate the puncture and puncture performance of the acupuncture needle. Currently, the more appropriate method is to use the needle tip to pierce through polyurethane material; however, this method has not yet been implemented internationally.Cons
22、idering the consistency of standards in the future, this standard provides the methods to evaluate the puncture performance of the needle tip and ranks 5.3.5.2 as recommended. The standard does not provide the sharpness index of the piercing through polyurethane material by the needle tip. This inde
23、x will be added to the standard when it becomes appropriate. To improve product quality, all inspection reports should include the inspection information as well as the results of the performance evaluation.Since every manufacturers design, production, and sterilization methods are different, no reg
24、ulations exist for the materials of the acupuncture needle handle. Still, the needle body and the needle handle of acupuncture needle should have good biocompatibility. In order to ensure product safety and efficacy, the manufacturer should perform risk analysis and enforce risk management in additi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO172182014STERILEACUPUNCTURENEEDLESFORSINGLEUSE 一次性 无菌 针灸 PDF

链接地址:http://www.mydoc123.com/p-585281.html