BS ISO 16028-2000 Hydraulic fluid power - Flush-face type quick-action couplings for use at pressures of 20 MPa (200 bar) to 31 5 MPa (315 bar) - Specifications《液压流体动力 在20MPa(200巴).pdf
《BS ISO 16028-2000 Hydraulic fluid power - Flush-face type quick-action couplings for use at pressures of 20 MPa (200 bar) to 31 5 MPa (315 bar) - Specifications《液压流体动力 在20MPa(200巴).pdf》由会员分享,可在线阅读,更多相关《BS ISO 16028-2000 Hydraulic fluid power - Flush-face type quick-action couplings for use at pressures of 20 MPa (200 bar) to 31 5 MPa (315 bar) - Specifications《液压流体动力 在20MPa(200巴).pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS ISO 16028:1999 ICS 23.
2、100.40 Hydraulic fluid power Flush-face type, quick-action couplings for use at pressures of 20 MPa (200 bar) to 31,5 MPa (315 bar) Specifications Incorporating Amendment No. 1 This British Standard, having been prepared under the direction of the Engineering Sector Committee, was published under th
3、e authority of the Standards Committee and comes into effect on 15 April 2000 ISBN 0 580 34652 8 BS ISO 16028:1999 National foreword BSI 2006 Amendments issued since publication Amd. No. Date Comments 16680 31 October 2006 Changes to Clause 1 and Subclause 5.2 This British Standard was published by
4、BSI. It is the UK implementation of ISO 16028:1999, including Amendment 1:2006, and implements it as the UK national standard. The UK participation in its preparation was entrusted by Technical Committee MCE/18, Fluid power systems and components, to Subcommittee MCE/18/-/4, Connectors and associate
5、d components. A list of organizations represented on MCE/18/-/4 can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer im
6、munity from legal obligations.Referencenumber ISO16028:1999(E) INTERNATIONAL STANDARD ISO 16028 Firstedition 1999-12-15 HydraulicfluidpowerFlush-facetype, quick-actioncouplingsforuseatpressures of20MPa(200bar)to31,5MPa(315bar) Specifications Transmissions hydrauliques Raccords rapides de type face p
7、lane pour usage des pressions de 20 MPa (200 bar) 31,5 MPa (315 bar) Spcificationsii ISO16028:1999(E)ISO16028:1999(E)iii Foreword ISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies(ISO memberbodies).TheworkofpreparingInternationalStandardsisnormallycar
8、riedoutthroughISOtechnical committees.Eachmemberbodyinterestedinasubjectforwhichatechnicalcommitteehasbeenestablishedhas therighttoberepresentedonthatcommittee.Internationalorganizations,governmentalandnon-governmental,in liaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththeInternationa
9、lElectrotechnical Commission(IEC)onallmattersofelectrotechnicalstandardization. InternationalStandardsaredraftedinaccordancewiththerulesgivenintheISO/IECDirectives,Part3. DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtothememberbodiesforvoting. PublicationasanInternationalSt
10、andardrequiresapprovalbyatleast75%ofthememberbodiescastingavote. AttentionisdrawntothepossibilitythatsomeoftheelementsofthisInternationalStandardmaybethesubjectof patentrights.ISOshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights. InternationalStandardISO16028waspreparedbyTechnicalCommi
11、tteeISO/TC131, Fluid power systems, SubcommitteeSC4, Connectors and similar products and components.ISO16028:1999(E) iv Introduction Inhydraulicfluidpowersystems,poweristransmittedandcontrolledthroughaliquidunderpressurewithinan enclosedcircuit.Quick-actioncouplingsareusedtojoinorseparatequicklyflui
12、dconductorlines,withouttheuse oftoolsorspecialdevices.INTERNATIONALSTANDARD ISO16028:1999(E)1 HydraulicfluidpowerFlush-facetype,quick-actioncouplings foruseatpressuresof20MPa(200bar)to31,5MPa(315bar) Specifications 1 Scope CouplingsinaccordancewiththisInternationalStandardarenotdesignedtoconnectordi
13、sconnectunder pressure. NOTE CouplingsinaccordancewiththisInternationalStandardprovideforautomaticsealingofthefluidpressureonthe upstreamsideandonthedownstreamsidewhenthecouplingisdisconnected. 2 Normativereferences Thefollowingnormativedocumentscontainprovisionswhich,throughreferenceinthistext,cons
14、tituteprovisionsof thisInternationalStandard.Fordatedreferences,subsequentamendmentsto,orrevisionsof,anyofthese publicationsdonotapply.However,partiestoagreementsbasedonthisInternationalStandardareencouragedto investigatethepossibilityofapplyingthemostrecenteditionsofthenormativedocumentsindicatedbe
15、low.For undatedreferences,thelatesteditionofthenormativedocumentreferredtoapplies.MembersofISOandIEC maintainregistersofcurrentlyvalidInternationalStandards. ISO4397, Fluid power systems and components Connectors and associated components Nominal outside diameters of tubes and nominal inside diamete
16、rs of hoses. ISO4399, Fluid power systems and components Connectors and associated components Nominal pressures. ISO5598, Fluid power systems and components Vocabulary. ISO7241-2, Hydraulic fluid power Quick-action couplings Part 2: Test methods. 3 Termsanddefinitions ForthepurposesofthisInternation
17、alStandard,thetermsanddefinitionsgiveninISO5598apply. 4 Dimensionalrequirements Hydraulicflushfacequick-actioncouplingsshallconformtothedimensionsshowninFigure1andgiveninTable1. Thecouplingsizerelatestothenominalinsidediameterofthehose,inaccordancewithISO4397,thatis recommendedforusewiththecoupling.
18、 ThisInternationalStandardspecifiestheinterfacedimensionsforinterchangeabilityandspecifiestheperformance requirementsforhydraulic,flush-facetype,quick-actioncouplingsforuseatpressuresof20MPa(200bar)to 31,5MPa(315bar), depending upon the coupling size.ISO16028:1999(E) 2 5 Performancerequirements 5.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO160282000HYDRAULICFLUIDPOWERFLUSHFACETYPEQUICKACTIONCOUPLINGSFORUSEATPRESSURESOF20MPA200BARTO315MPA315BARSPECIFICATIONS

链接地址:http://www.mydoc123.com/p-584909.html