BS ISO 15900-2009 Determination of particle size distribution - Differential electrical mobility analysis for aerosol particles《粒度分布测定 气溶胶粒子的差异性电移动性分析》.pdf
《BS ISO 15900-2009 Determination of particle size distribution - Differential electrical mobility analysis for aerosol particles《粒度分布测定 气溶胶粒子的差异性电移动性分析》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 15900-2009 Determination of particle size distribution - Differential electrical mobility analysis for aerosol particles《粒度分布测定 气溶胶粒子的差异性电移动性分析》.pdf(68页珍藏版)》请在麦多课文档分享上搜索。
1、BS ISO15900:2009ICS 19.120NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDDeterminationof particle sizedistribution Differential electricalmobility analysis foraerosol particlesThis British Standardwas published under theauthority of the StandardsPolicy and Stra
2、tegyCommittee on 30 June2009. BSI 2009ISBN 978 0 580 59614 8Amendments/corrigenda issued since publicationDate CommentsBS ISO 15900:2009National forewordThis British Standard is the UK implementation of ISO 15900:2009.The UK participation in its preparation was entrusted to TechnicalCommittee LBI/37
3、, Particle characterization including sieving.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a B
4、ritish Standard cannot confer immunityfrom legal obligations.BS ISO 15900:2009Reference numberISO 15900:2009(E)ISO 2009INTERNATIONAL STANDARD ISO15900First edition2009-05-15Determination of particle size distribution Differential electrical mobility analysis for aerosol particles Dtermination de la
5、distribution granulomtrique Analyse de mobilit lectrique diffrentielle pour les particules darosol BS ISO 15900:2009ISO 15900:2009(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited un
6、less the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a tradema
7、rk of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies.
8、In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2009 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means
9、, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrig
10、htiso.org Web www.iso.org Published in Switzerland ii ISO 2009 All rights reservedBS ISO 15900:2009ISO 15900:2009(E) ISO 2009 All rights reserved iiiContents Page Foreword iv Introduction v 1 Scope . 1 2 Terms and definitions. 1 3 Symbols . 4 4 General principle. 5 4.1 Particle size classification w
11、ith the DEMC. 5 4.2 Relationship between electrical mobility and particle size 6 4.3 Measurement and data inversion 7 4.4 Transfer function of the DEMC 8 4.5 The charge distribution function. 8 5 System and apparatus 9 5.1 General configuration. 9 5.2 Components 10 6 Measurement procedures 11 6.1 Se
12、tup and preparation of the instrument .11 6.2 Pre-measurement checks 14 6.3 Measurement. 14 6.4 Maintenance 15 7 Periodic tests and calibrations 16 7.1 Overview 16 7.2 Leak test 16 7.3 Zero tests. 17 7.4 Flow meter calibration 17 7.5 Voltage calibration 17 7.6 Particle charge conditioner integrity t
13、est. 18 7.7 Calibration for size measurement . 18 7.8 Size resolution test. 19 7.9 Number concentration calibration 20 8 Reporting of results 20 Annex A (informative) Particle charge conditioners and charge distributions . 21 Annex B (informative) Particle detectors. 29 Annex C (informative) Slip co
14、rrection factor. 33 Annex D (informative) Data inversion 37 Annex E (informative) Cylindrical DEMC . 43 Annex F (informative) Size calibration of a DMAS with step-wise voltage change using particle size standards . 49 Annex G (informative) Uncertainty . 52 Bibliography . 55 BS ISO 15900:2009ISO 1590
15、0:2009(E) iv ISO 2009 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member b
16、ody interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electro
17、technical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted
18、by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent r
19、ights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 15900 was prepared by Technical Committee ISO/TC 24, Particle characterization including sieving, Subcommittee SC 4, Particle characterization. BS ISO 15900:2009ISO 15900:2009(E) ISO 2009 All rights reserved
20、vIntroduction Differential electrical mobility classification and analysis of airborne particles has been widely used to measure a variety of aerosol particles ranging from nanometre-size to micrometre-size in the gas phase. In addition, the electrical mobility classification of charged particles ca
21、n be used to generate mono-disperse particles of known size for calibration of other instruments. One notable feature of these techniques is that they are based on simple physical principles. The techniques have become important in many fields of aerosol science and technology, e.g. aerosol instrume
22、ntation, production of materials from aerosols, contamination control in the semiconductor industry, atmospheric aerosol science, characterization of engineered nanoparticles, and so on. However, in order to use electrical mobility classification and analysis correctly, several issues, such as the s
23、lip correction factor, the ion-aerosol attachment coefficients, the size-dependent charge distribution on aerosol particles and the method used for inversion of the measured mobility distribution to the aerosol size distribution, need due caution. There is, therefore, a need to establish an Internat
24、ional Standard for the use of differential electrical mobility analysis for classifying aerosol particles. Its purpose is to provide a methodology for adequate quality control in particle size and number concentration measurement with this method. BS ISO 15900:2009BS ISO 15900:2009INTERNATIONAL STAN
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO159002009DETERMINATIONOFPARTICLESIZEDISTRIBUTIONDIFFERENTIALELECTRICALMOBILITYANALYSISFORAEROSOLPARTICLES

链接地址:http://www.mydoc123.com/p-584872.html