BS ISO 15570-1999 Practice for use of cellulose acetate dosimetry system《纤维素乙酸酯辐射剂量测定系统的实施规程》.pdf
《BS ISO 15570-1999 Practice for use of cellulose acetate dosimetry system《纤维素乙酸酯辐射剂量测定系统的实施规程》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 15570-1999 Practice for use of cellulose acetate dosimetry system《纤维素乙酸酯辐射剂量测定系统的实施规程》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 15570:1998 Practice for use of cellulose acetate dosimetry system ICS 17.240BSISO15570:1998 This British Standard, having been prepared under the directionof the Engineering SectorCommittee, was publishedunder the authority ofthe Standards Committee andcomes into effect on 15
2、 August 1999 BSI 04-2000 ISBN 0 580 32908 9 National foreword This British Standard reproduces verbatim ISO15570:1998 and implements it as the UK national standard. The UK participation in its preparation was entrusted to Technical Committee NCE/2, Health physics instrumentation, which has the respo
3、nsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A l
4、ist of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “Internati
5、onal Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a Brit
6、ish Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theISO title page, pages ii to iv, pages 1 to 11 and a back cover. This standard has been updated (see copyright date) and may have h
7、ad amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSISO15570:1998 BSI 04-2000 i Contents Page National foreword Inside front cover Foreword iii Text of ISO 15570 1ii blankBSISO15570:1998 ii B
8、SI 04-2000 Contents Page Foreword iii 1 Scope 1 2 Referenced Documents 1 3 Terminology 2 4 Significance and Use 3 5 Apparatus 3 6 Performance Check of Instrumentation 3 7 Preparation of Dosimeters 4 8 Calibration of Dosimeters 5 9 Condition for Practical Use 7 10 Report 8 11 Precision and Bias 8 12
9、Keywords 8 Appendix X1 (nonmandatory information) Information on cellulose acetate (CTA and CDA) dosimeters 9 Figure 1 Absorption Spectra Before and After Irradiation of Untinted Cellulose Triacetate (CTA) Film with a 2 MeV Electron Beam 4 Figure 2 The Relation Between the Increment of Absorbance %A
10、/Nominal Thickness (0.125 mm) at 280 nm and Dose in Untinted CTA by Electron and Gamma-Radiation 4 Figure 3 Absorption Spectra Before and After Irradiation to High Doses (Using 60 Co Rays, 0.4- and 10-MeV Electron Beams) of Yellow Cellulose Diacetate (CDA) Film 5 Figure 4 Increase in the Reciprocal
11、of Absorbance (I/A), at 390 nm Wavelength, as a Function of Absorbed Dose (in Water), when Yellow CDA is Irradiated with Electrons and Gamma Rays (16) 6 Table X1.1 Basic Properties of Available Dosimeters 9 Table X1.2 An Example of Single Purpose Absorbance Measuring Devices for Cellulose Acetate Do
12、simeters 9 References 10BSISO15570:1998 BSI 04-2000 iii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees
13、. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the Intern
14、ational Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least75% of the member bodi
15、es casting a vote. International Standard ISO15570 was prepared by the American Society for Testing and Materials (ASTM) Subcommittee E10.01 (as E1650-94) and was adopted, under a special “fast-track procedure”, by Technical Committee ISO/TC85, Nuclear energy, in parallel with its approval by the IS
16、O member bodies. A new ISO/TC85 Working Group WG3, High level dosimetry for radiation processing, was formed to review the voting comments from the ISO “Fast-track procedure” and to maintain these standards. The USA holds the convenership of this working group. International Standard ISO15570 is one
17、 of20standards developed and published by ASTM. The20fast-tracked standards and their associated ASTM designations are listed below: ISO Designation ASTM Designation Title 15554 E 1204-93 Practice for dosimetry in gamma irradiation facilities for food processing 15555 E 1205-93 Practice for use of a
18、 ceric-cerous sulfate dosimetry system 15556 E 1261-94 Guide for selection and calibration of dosimetry systems for radiation processing 15557 E 1275-93 Practice for use of a radiochromic film dosimetry system 15558 E 1276-96 Practice for use of a polymethylmethacrylate dosimetry system 15559 E 1310
19、-94 Practice for use of a radiochromic optical waveguide dosimetry system 15560 E 1400-95a Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory 15561 E 1401-96 Practice for use of a dichromate dosimetry system 15562 E 1431-91 Practice for dosimetry
20、in electron and bremsstrahlung irradiation facilities for food processing 15563 E 1538-93 Practice for use of the ethanol-chlorobenzene dosimetry system 15564 E 1539-93 Guide for use of radiation-sensitive indicators 15565 E 1540-93 Practice for use of a radiochromic liquid dosimetry systemBSISO1557
21、0:1998 iv BSI 04-2000 15566 E 1607-94 Practice for use of the alanine-EPR dosimetry system 15567 E 1608-94 Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing 15568 E 1631-96 Practice for use of calorimetric dosimetry systems for electron beam dose measurements and
22、dosimeter calibrations 15569 E 1649-94 Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV 15570 E 1650-94 Practice for use of cellulose acetate dosimetry system 15571 E 1702-95 Practice for dosimetry in a gamma irradiation facility for
23、 radiation processing 15572 E 1707-95 Guide for estimating uncertainties in dosimetry for radiation processing 15573 E 1818-96 Practice for dosimetry in an electron-beam facility for radiation processing at energies between 80 keV and 300 keV ISO Designation ASTM Designation TitleBSISO15570:1998 BSI
24、 04-2000 1 1 Scope 1.1 This practice covers the preparation, handling, testing and procedures for the use of cellulose acetate dosimetry systems, and the spectrometric, densitometric, or photometric readout equipment for measuring absorbed dose in materials irradiated by photons and electrons in ter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO155701999PRACTICEFORUSEOFCELLULOSEACETATEDOSIMETRYSYSTEM 纤维素 乙酸 辐射 剂量 测定 系统 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-584737.html