BS ISO 15554-1999 Practice for dosimetry in gamma irradiation facilities for food processing《食品加工中γ射线辐射设备的辐射剂量测定的实施规程》.pdf
《BS ISO 15554-1999 Practice for dosimetry in gamma irradiation facilities for food processing《食品加工中γ射线辐射设备的辐射剂量测定的实施规程》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 15554-1999 Practice for dosimetry in gamma irradiation facilities for food processing《食品加工中γ射线辐射设备的辐射剂量测定的实施规程》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 15554:1998 Practice for dosimetry ingamma irradiation facilities for food processing ICS 17.240; 67.020BS ISO 15554:1998 This British Standard, having been prepared under the directionof the Engineering SectorCommittee, was publishedunder the authority ofthe Standards Committ
2、ee andcomes into effect on 15 August1998 BSI 03-2000 ISBN 0 580 32913 5 National foreword This British Standard reproduces verbatim ISO15554:1998 and implements it as the UK national standard. The UK participation in its preparation was entrusted to Technical Committee NCE/2, Health physics instrume
3、ntation, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and pr
4、omulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the
5、 section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct applica
6、tion. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theISO title page, pages ii to iv, pages 1 to 8 and abackcover. This standard has been updated (see copyr
7、ight date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBS ISO 15554:1998 BSI 03-2000 i Contents Page National foreword Inside front cover Foreword iii Text of ISO 15554 1i
8、i blankBSISO15554:1998 ii BSI 03-2000 Contents Foreword iii 1 Scope 1 2 Referenced Documents 1 3 Terminology 2 4 Significance and Use 3 5 Radiation Source Characteristics 3 6 Types of Facilities 3 7 Dosimetry Systems 3 8 Installation Qualification 4 9 Process Qualification 5 10 Routine Production Pr
9、ocessing 6 11 Certification 7 12 Precision and Bias 7 13 Keywords 7 Figure 1 An Example of the Maximum and Minimum Absorbed-Dose Locations in a Typical Product (17) 5 References 8BSISO15554:1998 BSI 03-2000 iii Foreword ISO (the International Organization for Standardization) is a worldwide federati
10、on of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee
11、. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with theInternational Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technic
12、al committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least75% of the member bodies casting a vote. International Standard ISO15554 was prepared by the American Society forTesting and Materials (ASTM) Subcommittee E10.01 (as E1
13、204-93) and wasadopted, under a special “fast-track procedure”, by Technical Committee ISO/TC 85, Nuclear energy, in parallel with its approval by the ISO member bodies. A new ISO/TC 85 Working Group WG 3, High-level dosimetry for radiation processing, was formed to review the voting comments from t
14、he ISO “Fast-track procedure” and to maintain these standards. The USA holds the convenership of this working group. International Standard ISO15554 is one of20 standards developed and published by ASTM. The20 fast-tracked standards and their associated ASTM designations are listed below: ISO Design
15、ation ASTM Designation Title 15554 E 1204-93 Practice for dosimetry in gamma irradiation facilities for food processing 15555 E 1205-93 Practice for use of a ceric-cerous sulfate dosimetry system 15556 E 1261-94 Guide for selection and calibration of dosimetry systems for radiation processing 15557
16、E 1275-93 Practice for use of a radiochromic film dosimetry system 15558 E 1276-96 Practice for use of a polymethylmethacrylate dosimetry system 15559 E 1310-94 Practice for use of a radiochromic optical waveguide dosimetry system 15560 E 1400-95a Practice for characterization and performance of a h
17、igh-dose radiation dosimetry calibration laboratory 15561 E 1401-96 Practice for use of a dichromate dosimetry system 15562 E 1431-91 Practice for dosimetry in electron and bremsstrahlung irradiation facilities for food processing 15563 E 1538-93 Practice for use of the ethanol-chlorobenzene dosimet
18、ry system 15564 E 1539-93 Guide for use of radiation-sensitive indicators 15565 E 1540-93 Practice for use of a radiochromic liquid dosimetry system 15566 E 1607-94 Practice for use of the alanine-EPR dosimetry systemBSISO15554:1998 iv BSI 03-2000 ISO Designation ASTM Designation Title 15567 E 1608-
19、94 Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing 15568 E 1631-96 Practice for use of calorimetric dosimetry systems for electron beam dose measurements and dosimeter calibrations 15569 E 1649-94 Practice for dosimetry in an electron-beam facility for radiation
20、 processing at energies between300keV and 25 MeV 15570 E 1650-94 Practice for use of cellulose acetate dosimetry system 15571 E 1702-95 Practice for dosimetry in a gamma irradiation facility for radiation processing 15572 E 1707-95 Guide for estimating uncertainties in dosimetry for radiation proces
21、sing 15573 E 1818-96 Practice for dosimetry in an electron-beam facility for radiation processing at energies between80keV and300keVBS ISO 15554:1998 BSI 03-2000 1 1 Scope 1.1 This practice outlines dosimetric procedures to be followed in irradiator characterization, process qualification, and routi
22、ne processing of food with ionizing radiation from isotopic gamma sources to ensure that all product has been treated within a predetermined range of absorbed dose. Other procedures related to irradiator characterization, process qualification, and routine processing that may influence absorbed dose
23、 in the product are also discussed. Information about effective or regulatory dose limits for food products is not within the scope of this practice (see Guides F1355 and F1356). NOTE 1Dosimetry is only one component of a total quality assurance program for adherence to good manufacturing practices
24、used in the production of safe and wholesome food. NOTE 2Practice E1431 describes dosimetric procedures for electron beam and bremsstrahlung (X-ray) irradiation facilities for food processing. 1.2 For guidance in the selection, calibration, and use of specific dosimeters, and interpretation of absor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO155541999PRACTICEFORDOSIMETRYINGAMMAIRRADIATIONFACILITIESFORFOODPROCESSING 食品 加工 射线 辐射 设备 剂量 测定

链接地址:http://www.mydoc123.com/p-584733.html