BS ISO 14972-1999 Sterile obturators for single use with over-needle peripheral intravascular catheters《带过度指针的外部血管内导管的一次使用消毒填塞器》.pdf
《BS ISO 14972-1999 Sterile obturators for single use with over-needle peripheral intravascular catheters《带过度指针的外部血管内导管的一次使用消毒填塞器》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 14972-1999 Sterile obturators for single use with over-needle peripheral intravascular catheters《带过度指针的外部血管内导管的一次使用消毒填塞器》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BSISO 14972:1998 Sterile obturators for single use with over-needle peripheral intravascular catheters ICS 11.040.20BSISO14972:1998 This British Standard, having been prepared under the directionof the Health and Environment Sector Committee, was published under the authorityof the
2、Standards Committee and comes intoeffecton 15 March1999 BSI 05-1999 ISBN 0 580 32122 3 National foreword This British Standard reproduces verbatim ISO14972:1998 and implements it as the UK national standard. The UK participation in its preparation was entrusted to Technical Committee CH/27, Medical
3、plastics tubing, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UKinterests informed; monitor related international and European developments
4、 and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue un
5、der the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct
6、application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theISO title page, pagesii toiv, pages1 to3 and a back cover. This standard has been updated (see
7、copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSISO14972:1998 BSI 05-1999 i Contents Page National foreword Inside front cover Foreword iii Text of ISO14972
8、1ii blankBSISO14972:1998 ii BSI05-1999 Contents Page Foreword iii 1 Scope 1 2 Normative references 1 3 Definition 1 4 Requirements 1 Annex A (normative) Method for determining force at break of the obturator 3 Annex B (informative) Bibliography 3 Figure 1 Example of obturator 1 Table 1 Force at brea
9、k 2 Table A.1 Example of conditions for a20mm/min/mm strain rate 3BSISO14972:1998 BSI 05-1999 iii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally ca
10、rried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work
11、. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires
12、approval by at least75% of the member bodies casting a vote. International Standard ISO14972 was prepared by Technical Committee ISO/TC84, Medical devices for injections, Subcommittee SC1, Syringes, needles and intravascular catheters for single use. Annex A forms a normative part of this Internatio
13、nal Standard. Annex B is for information only.iv blankBSISO14972:1998 BSI 05-1999 1 1 Scope This International Standard specifies requirements for obturators, supplied in the sterile condition and intended for single use for plugging over-needle peripheral catheters. NOTEAttention is drawn to ISO105
14、55-5, which specifies requirements for over-needle peripheral catheters. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, the editions indicated were valid. All s
15、tandards are subject to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain registers of currently valid International Standards.
16、ISO594-1:1986, Conical fittings with a6% (Luer) taper for syringes, needles and certain other medical equipment Part1:General requirements. ISO594-2:1998, Conical fittings with a6% (Luer) taper for syringes, needles and certain other medical equipment Par2:Lock fittings. 3 Definition For the purpose
17、s of this International Standard, the following definition applies. 3.1 obturator device designed to be inserted into an over-needle peripheral catheter to plug the lumen of the catheter see Figure 1 4 Requirements 4.1 General The obturator shall have been sterilized by a validated method and it sha
18、ll comply with the requirements given in4.2 to4.10 in the sterile condition. NOTESee ISO11134, ISO11135 and ISO11137 for appropriate methods of sterilization. Figure 1 Example of obturatorBSISO14972:1998 2 BSI 05-1999 4.2 Biocompatibility The obturator shall be free from biological hazard. NOTESee I
19、SO10993-1 for the selection of appropriate test methods. 4.3 Surface When examined by normal or corrected-to-normal vision with2,5 magnification, the external surface of the effective length of the obturator shaft shall appear free from extraneous matter. The external surface and the tip of the obtu
20、rator shaft should be free from surface defects in order to minimize trauma to vessels during use. 4.4 Force at break When tested in accordance with the method given in Annex A, the force at break of the obturator shall be as given in Table 1. 4.5 Luer fitting The Luer fitting shall comply with ISO5
21、94-1 or ISO594-2. 4.6 Outside diameter The outside diameter of the obturator shaft shall be compatible with the inside diameter of the over-needle peripheral catheter(s) with which it is intended to be used in order to plug the lumen of the catheter. 4.7 Effective length When the obturator is fully
22、inserted into the over-needle peripheral catheter, the tip of the obturator shall either coincide with the tip of the catheter or shall extend from the tip of the catheter by no more than3,0mm. 4.8 Colour code The obturator shall be colour-coded with the colour code of the over-needle peripheral cat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO149721999STERILEOBTURATORSFORSINGLEUSEWITHOVERNEEDLEPERIPHERALINTRAVASCULARCATHETERS 过度 指针 外部 血管

链接地址:http://www.mydoc123.com/p-584591.html