BS ISO 14291-2012 Vacuum gauges Definitions and specifications for quadrupole mass spectrometers《真空计 四极质谱仪定义和规格》.pdf
《BS ISO 14291-2012 Vacuum gauges Definitions and specifications for quadrupole mass spectrometers《真空计 四极质谱仪定义和规格》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 14291-2012 Vacuum gauges Definitions and specifications for quadrupole mass spectrometers《真空计 四极质谱仪定义和规格》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS ISO 14291:2012Vacuum gauges Definitions and specificationsfor quadrupole massspectrometersBS ISO 14291:2012 BRITISH STANDARDNational forewordThis British Standard is the UK im
2、plementation of ISO 14291:2012.The UK participation in its preparation was entrusted to TechnicalCommittee MCE/8/-/4, Vacuum technology.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovi
3、sions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 74400 6ICS 23.160Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published und
4、er the authority of theStandards Policy and Strategy Committee on 31 August 2012.Amendments issued since publicationDate Text affectedBS ISO 14291:2012 ISO 2012Vacuum gauges Definitions and specifications for quadrupole mass spectrometersManomtres vide Dfinitions et spcifications des spectromtres de
5、 masse quadripolairesINTERNATIONAL STANDARDISO14291First edition2012-07-15Reference numberISO 14291:2012(E)BS ISO 14291:2012ISO 14291:2012(E)ii ISO 2012 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2012All rights reserved. Unless otherwise specified, no part of this publication may be reprodu
6、ced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01
7、 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 14291:2012ISO 14291:2012(E) ISO 2012 All rights reserved iiiContents PageForeword ivIntroduction v1 Scope 12 Terms and definitions . 12.1 Definitions of components 12.2 Definitions of physical parameters . 5
8、3 Symbols and abbreviated terms . 84 Principle of QMS 95 Specifications for a QMS to be provided by manufacturers . 95.1 Mass range 95.2 Type of ion source . 95.3 Type of ion detector 95.4 Mass resolution .105.5 Mass number stability 105.6 Sensitivity 105.7 Linear response range .105.8 Minimum detec
9、table partial pressure 105.9 Minimum detectable concentration 105.10 Maximum operational pressure .105.11 Scanning parameter .105.12 Signal output 115.13 Potentials . 115.14 Detector specifications 115.15 Set point . 115.16 Maximum bake-out temperature . 115.17 Nominal operating conditions 115.18 Wa
10、rm-up time . 115.19 Filament material . 115.20 Electron emission current . 115.21 Filament exchange 115.22 Detector exchange 115.23 Fitting to chamber .125.24 Mounting orientation 125.25 Dimensions .125.26 Internal volume 125.27 Mass of sensor head and electronic unit 125.28 Input power of electroni
11、c unit 125.29 Cable .125.30 Software .125.31 Interface .125.32 Storage and transportation condition126 Optional specifications for QMS to be provided by manufacturers 136.1 Mass resolution .136.2 Fragmentation or cracking pattern .136.3 Temperature coefficient of sensitivity .136.4 QMS sensor cleani
12、ng .136.5 Degassing 136.6 Degassing power .136.7 Photographs .136.8 Inspection record 136.9 Outgassing rate .13Bibliography .14BS ISO 14291:2012ISO 14291:2012(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies)
13、. The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non
14、-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part
15、2.The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a
16、vote.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights.ISO 14291 was prepared by Technical Committee ISO/TC 112, Vacuum technology.iv ISO 2012 All right
17、s reservedBS ISO 14291:2012ISO 14291:2012(E)IntroductionQuadrupole mass spectrometers (QMSs) are nowadays used not only for leak detection and residual gas analysis in vacuum but also as instruments to provide quantitative analysis in processes and control processes such as physical and chemical vap
18、or deposition, and etch processes.Total pressure, composition of the gas mixture, QMS settings, environment conditions, etc., have a significant influence on the measured signal, its uncertainty and interpretation. For this reason, it is not possible to calibrate QMS for all its possible application
19、s. Instead, it has either to be calibrated for the particular conditions of use or for a standardized condition.There is also some need for standardization in order to enable QMS users to compare devices of different manufacturers and to use the QMS properly.In continuation of efforts of TC 112 duri
20、ng the 1990s, this International Standard takes a first step towards establishment of a standardized calibration procedure for QMS by defining the terms and parameters. ISO 2012 All rights reserved vBS ISO 14291:2012BS ISO 14291:2012Vacuum gauges Definitions and specifications for quadrupole mass sp
21、ectrometers1 ScopeThis International Standard defines terms relevant to quadrupole mass spectrometers (QMSs) and specifies the parameters required for specification by QMS manufacturers necessary for proper calibration and for maintaining the quality of partial pressure measurement.This Internationa
22、l Standard applies to QMSs with an ion source of the electron impact ionization type. Such QMSs are designed for the measurement of atomic mass-to-charge ratios m/z typically 300. QMSs with other ion sources, such as those of the chemical ionization, photoionization, and field ionization types, as w
23、ell as the measurements of m/z above 300, which are mainly used to specify organic materials, lie outside the scope of this International Standard.2 Terms and definitionsFor the purposes of this document, the following terms and definitions apply.2.1 Definitions of components2.1.1quadrupole mass spe
24、ctrometerQMSmass spectrometer in which ions are injected axially into a quadrupole lens consisting of a system of four electrodes, usually rods, to which radio frequency and d.c. electric fields in a critical ratio are applied, so that only ions with a certain mass/charge ratio emergeSOURCE: ISO 352
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO142912012VACUUMGAUGESDEFINITIONSANDSPECIFICATIONSFORQUADRUPOLEMASSSPECTROMETERS 真空计 质谱仪 定义 规格 PDF

链接地址:http://www.mydoc123.com/p-584391.html