BS ISO 13347-2-2004 Industrial fans - Determination of fan sound power levels under standardized laboratory conditions - Reverberant room method《工业风扇 标准实验室条件下风扇声功率级的测定 混响室法》.pdf
《BS ISO 13347-2-2004 Industrial fans - Determination of fan sound power levels under standardized laboratory conditions - Reverberant room method《工业风扇 标准实验室条件下风扇声功率级的测定 混响室法》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 13347-2-2004 Industrial fans - Determination of fan sound power levels under standardized laboratory conditions - Reverberant room method《工业风扇 标准实验室条件下风扇声功率级的测定 混响室法》.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS ISO 13347-2:2004BS 848-2.2:2004Incorporating corrigendum no. 1Industrial fans Determination of fan sound power levels under standardized laboratory conditions Part 2: Reverberant room methodICS 17.140.20; 23.120g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g4
2、0g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS ISO 13347-2:2004This British Standard was published under the authority of the Standards Policy and Strategy Committee on 25 August 2004 BSI 2006ISBN 0 580 44360 4 Nat
3、ional forewordThis British Standard was published by BSI. It is the UK implementation of ISO 13347-2:2004, incorporating corrigendum October 2006. Together with BS ISO 13347-1:2004 (BS 848-2.1:2004), BS ISO 13347-3:2004 (BS 848-2.3:2004), BS ISO 13447-4:2004 (BS 848-2.4:2004), it supersedes BS 848-2
4、:1985, which is now withdrawn.The start and finish of text introduced or altered by ISO corrigendum October 2006 is indicated in the text by CC.The UK participation in its preparation was entrusted to Technical Committee MCE/17, Industrial fans.A list of organizations represented on this committee c
5、an be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot of itself confer immunity from legal obligations.Amendments issued since pu
6、blicationAmd. No. Date Comments16790 Corrigendum No. 129 December 2006 See national forewordReference numberISO 13347-2:2004(E)INTERNATIONAL STANDARD ISO13347-2First edition2004-08-15Industrial fans Determination of fan sound power levels under standardized laboratory conditions Part 2: Reverberant
7、room method Ventilateurs industriels Dtermination des niveaux de puissance acoustique des ventilateurs dans des conditions de laboratoire normalises Partie 2: Mthode de la salle rverbrante BS ISO 133472:2004ii IS-74331 O2:(4002E) iiiContents Page Foreword iv Introduction v 1 Scope 1 2 Normative refe
8、rences . 1 3 Limitations on use 2 4 Field of application . 2 5 Instrumentation . 3 6 Test method. 3 7 Acoustic environment 3 8 Test set-up and ducting 3 9 Observations . 10 10 Calculations. 10 Annex A (normative) Room qualification for sound sources with broad band sound . 12 Annex B (informative) R
9、oom qualification for sound sources with pure tones/narrow-band sound 14 Annex C (informative) Total fan sound testing with attached ducts. 18 Annex D (normative) Transmission element . 20 Bibliography . 22 BS ISO 133472:2004IS-74331 O2:(4002E) iv Foreword ISO (the International Organization for Sta
10、ndardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the righ
11、t to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International
12、Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an
13、 International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 1
14、3347-2 was prepared by Technical Committee ISO/TC 117, Industrial fans. ISO 13347 consists of the following parts, under the general title Industrial fans Determination of fan sound power levels under standardized laboratory conditions: Part 1: General overview Part 2: Reverberant room method Part 3
15、: Enveloping surface methods Part 4: Sound intensity method BS ISO 133472:2004IS-74331 O2:(4002E) vIntroduction The need for this new International Standard, ISO 13347, has been evident for some time. Whilst a number of national standards exist for the measurement of fan noise, none has received uni
16、versal acceptance nor may comparisons be readily made. Forming part of the ISO/TC 117 series of fan standards, this part of ISO 13347 deals with the determination of the fan sound power level appropriate to a particular application. In describing the test and rating procedures, numerous references a
17、re made to ISO 5801 as well as to other relevant ISO standards. This reverberant room method should be read in conjunction with ISO 13447-1 and each parts of ISO 13347 which details other methods for determining the sound power radiated by a fan in specified installation conditions as a function of
18、frequency. This part of ISO 13347 primarily deals with the determination of sound power levels of industrial fans used for ducted applications. The test procedures described in this part of ISO 13347 relate to laboratory conditions. The measurement of performance under site conditions is not include
19、d. Acoustic system effects can be considerable where the airflow into and out of the fan is not free from swirl, nor the velocity profile there fully developed. This part of ISO 13347 describes methods for determining sound power levels of fans in one-third octave bandwidths. Data obtained in accord
20、ance with this part of ISO 13347 may be used for the following purposes amongst others: a) comparison of fans which are similar in size and type; b) comparison of fans which are different in size and type; c) determining whether a fan complies with a specified upper limit of sound emission; d) scali
21、ng of fan noise from one size and speed to another size and speed; e) prediction of sound pressure level in an installation of which the fan forms a part; f) engineering work to assist in developing quiet machinery and equipment. BS ISO 133472:2004blank1Industrial fans Determination of fan sound pow
22、er levels under standardized laboratory conditions Part 2: Reverberant room method 1 Scope This part of ISO 13347 gives a detailed description of reverberant room methods for the determination of fan sound power levels. It is for use under standardized laboratory conditions and recognises that tests
23、 in situ are subject to increased uncertainty. These test procedures are not necessarily appropriate to site test conditions. Acoustic system effects are presently the subject of considerable research effort. ISO 5136, which covers the in-duct method, and ISO 10302 for small fans, should be used in
24、conjunction with this part of ISO 13347. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1334722004INDUSTRIALFANSDETERMINATIONOFFANSOUNDPOWERLEVELSUNDERSTANDARDIZEDLABORATORYCONDITIONSREVERBERANTROOMMETHOD

链接地址:http://www.mydoc123.com/p-584138.html