BS ISO 11933-3-1999 Components for containment enclosures - Transfer systems such as plain doors airlock chambers double door transfer systems leaktight connections for waste drums.pdf
《BS ISO 11933-3-1999 Components for containment enclosures - Transfer systems such as plain doors airlock chambers double door transfer systems leaktight connections for waste drums.pdf》由会员分享,可在线阅读,更多相关《BS ISO 11933-3-1999 Components for containment enclosures - Transfer systems such as plain doors airlock chambers double door transfer systems leaktight connections for waste drums.pdf(52页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 11933-3:1998 Components for containment enclosures Part3: Transfer systems such as plain doors, airlock chambers, double door transfer systems, leaktight connections for waste drums ICS13.280BSISO11933-3:1998 This BritishStandard, having been prepared under the directionof th
2、e Engineering SectorCommittee, was publishedunder the authority ofthe Standards Committee andcomes into effect on 15April1999 BSI05-2000 ISBN 0 580 30960 6 National foreword This BritishStandard reproduces verbatim ISO11933-3:1998 and implements it as the UK national standard. The UK participation i
3、n its preparation was entrusted to Technical Committee NCE/2, Health physics instrumentation, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the
4、UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The BritishStandards which implement international or European publication
5、s referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions
6、 of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theISO title page, pa
7、gesii tovi, pages1 to40 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSISO11933-3:1998 BSI 05-2000 i C
8、ontents Page National foreword Inside front cover Foreword v Text of ISO11933-3 1ii blankBSISO11933-3:1998 ii BSI 05-2000 Contents Page Foreword v Introduction 1 1 Scope 1 2 Normative references 1 3 Definitions 2 4 Designation 2 4.1 Explanation of the reference number 2 4.1.1 Series allocation 2 4.1
9、.2 Alphabetical codes corresponding to the mounting procedures 3 4.1.3 Alphabetical codes corresponding to the construction materials 3 4.2 Designation Examples and explanation 3 4.2.1 Plain doors 3 4.2.2 Airlock chambers 4 4.2.3 Double door transfer systems 5 4.2.4 Leaktight connections for waste d
10、rums 5 5 Plain doors 5 5.1 General 5 5.1.1 Application 5 5.1.2 Precautions for opening the doors 5 5.1.3 Choice of the leaktight system (way of locking) 6 5.2 Description 6 5.2.1 Shape 6 5.2.2 Assembly 7 5.2.3 Materials 8 5.2.4 Seals 8 5.2.5 Dimensions 9 5.2.6 Examples 11 6 Airlock chambers (seeFigu
11、re 6) 11 6.1 General 11 6.2 Various types of airlock chambers 11 6.2.1 Classification according to the ventilation mode 11 6.2.2 Classification according to the geometrical shape 13 6.3 Precautions to be taken during use of an airlock chamber 13 6.4 Ventilation of airlock chambers 13 6.5 Description
12、 13 6.5.1 Shape 13 6.5.2 Assembly (seeFigure 9) 13 6.5.3 Material 15 6.5.4 Doors for airlock chambers 15 6.5.5 Dimensions 16 6.5.6 Examples 18 7 Double door transfer systems 18 7.1 General 18 7.2 Type1 double door transfer systems 19 7.2.1 General 19 7.2.2 Principle of use 20 7.2.3 Assembly 21 7.2.4
13、 Material 22 7.2.5 Dimensions (seeFigure 16) 22 7.3 Type2 double door transfer systems 23BSISO11933-3:1998 BSI 05-2000 iii Page 7.3.1 General 23 7.3.2 Operation 24 7.3.3 Assembly 25 7.3.4 Material 26 7.3.5 Dimensions (seeFigure 20) 26 8 Leaktight connections for waste drums 27 8.1 General 27 8.2 Pri
14、nciple of use 28 8.3 Type1 leaktight connections for waste drums 29 8.3.1 General 29 8.3.2 Operation 30 8.3.3 Material 30 8.3.4 Dimensions (seeFigure 24) 30 8.4 Type2 leaktight connections for waste drums 31 8.4.1 General 31 8.4.2 Operation 32 8.4.3 Material 32 8.4.4 Dimensions (seeFigure 26) 32 Ann
15、ex A (informative) Examples of plain doors and airlock chambers 34 Annex B (informative) Bibliography 40 Figure 1 Door for containment enclosures 6 Figure 2 Examples of ways of locking the doors 7 Figure 3 Different ways of mounting the doors 8 Figure 4 Standard dimensions of circular plain doors 9
16、Figure 5 Standard dimensions of rectangular or square plain doors 10 Figure 6 General view of an airlock chamber 11 Figure 7 Various types of airlock chambers 12 Figure 8 Different profiles of airlock chambers 14 Figure 9 Various ways of assembling airlock chambers 15 Figure 10 Dimensions of introdu
17、ction airlock chambers 16 Figure 11 Dimensions of T-shaped airlock chambers 18 Figure 12 Principle of double door transfer system 19 Figure 13 Type1 double door transfer system 20 Figure 14 Operating principle of a type1 double door transfer system 21 Figure 15 Mounting of the flange 22 Figure 16 Di
18、mensions of type1 double door transfer systems 23 Figure 17 Type2 double door transfer system 24 Figure 18 Operating principle of a type2 double door transfer system 25 Figure 19 Mounting of the double door transfer system 26 Figure 20 Dimensions of type2 double door transfer system 27 Figure 21 Lea
19、ktight connection system for waste drums 28 Figure 22 Operating principle of leaktight connection systems for wastedrums 29 Figure 23 Type1 leaktight connection for waste drums 30 Figure 24 Dimensions of type1 leaktight connection for waste drums 31 Figure 25 Type2 leaktight connection for waste dru
20、ms 32 Figure 26 Dimensions of type2 leaktight connection for waste drums 33 Figure A.1 General view of refrigerator-type door 34BSISO11933-3:1998 iv BSI 05-2000 Page Figure A.2 General view of inflatable-seal sliding door 35 Figure A.3 Detail of components of inflation-seal sliding door 35 Figure A.
21、4 Operating principle of inflatable-seal sliding door 36 Figure A.5 General view of sliding door operated by lifting 36 Figure A.6 Operating principle of sliding door (lifting) 37 Figure A.7 Detail of components 38 Figure A.8 Operating principle 39 Figure A.9 General view 40 Figure A.10 Detail of mo
22、unting 40 Table 1 Series allocation 3 Table 2 Correlation between the reference numbers of plain doors and the useful diameters of ports receiving plain doors 4 Table 3 Correlation between the reference numbers of plain doors/airlock chambers and the useful diameters of related transfer systems 4 Ta
23、ble 4 Standard dimensions of circular plain doors 9 Table 5 Standard dimensions of rectangular or square plain doors 10 Table 6 Standard dimensions of introduction airlock chambers with circular cross-section 16 Table 7 Standard dimensions of introduction airlock chambers with square or rectangular
24、cross-section 17 Table 8 Standard dimensions of linking or introduction airlock chambers with circular cross-section 17 Table 9 Standard dimensions of linking or introduction airlock chambers with square or rectangular cross-section 18 Table 10 Standard dimensions of type1 double door transfer syste
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1193331999COMPONENTSFORCONTAINMENTENCLOSURESTRANSFERSYSTEMSSUCHASPLAINDOORSAIRLOCKCHAMBERSDOUBLEDOORTRANSFERSYSTEMSLEAKTIGHTCONNECTIONSFORWASTEDRUMSPDF

链接地址:http://www.mydoc123.com/p-583736.html