BS ISO 10094-1-2010 Pneumatic fluid power Electro-pneumatic pressure control valves Main characteristics to include in the supplier-s literature《气动流体动力 电气压控制阀 包含在供应商文件中的主要特征》.pdf
《BS ISO 10094-1-2010 Pneumatic fluid power Electro-pneumatic pressure control valves Main characteristics to include in the supplier-s literature《气动流体动力 电气压控制阀 包含在供应商文件中的主要特征》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 10094-1-2010 Pneumatic fluid power Electro-pneumatic pressure control valves Main characteristics to include in the supplier-s literature《气动流体动力 电气压控制阀 包含在供应商文件中的主要特征》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS ISO 10094-1:2010Pneumatic fluid power Electro-pneumatic pressurecontrol valvesPart 1: Main characteristics to include in thesuppliers literatureBS ISO 10094-1:2010 BRITISH STA
2、NDARDNational forewordThis British Standard is the UK implementation of ISO 10094-1:2010.The UK participation in its preparation was entrusted to TechnicalCommittee MCE/18/-/5, Control components.A list of organizations represented on this committee can beobtained on request to its secretary.This pu
3、blication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2010ISBN 978 0 580 66275 1ICS 23.100.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the
4、authority of theStandards Policy and Strategy Committee on 30 November 2010.Amendments issued since publicationDate Text affectedBS ISO 10094-1:2010Reference numberISO 10094-1:2010(E)ISO 2010INTERNATIONAL STANDARD ISO10094-1First edition2010-10-15Pneumatic fluid power Electro-pneumatic pressure cont
5、rol valves Part 1: Main characteristics to include in the suppliers literature Transmissions pneumatiques Appareils lectropneumatiques de distribution commande continue de pression Partie 1: Principales caractristiques inclure dans la documentation des fournisseurs BS ISO 10094-1:2010ISO 10094-1:201
6、0(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this f
7、ile, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info
8、relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. C
9、OPYRIGHT PROTECTED DOCUMENT ISO 2010 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address be
10、low or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2010 All rights reservedBS ISO 10094-1:2010ISO 10094-1:2010(E) ISO 2010
11、 All rights reserved iiiContents Page Foreword iv Introduction.v 1 Scope1 2 Normative references1 3 Terms and definitions .2 4 Symbols and units.2 5 Characteristics.3 5.1 General .3 5.2 Electric characteristics .3 5.3 Static characteristics 3 5.4 Dynamic characteristics .8 6 Identification statement
12、 (reference to this part of ISO 10094) .14 Bibliography15 BS ISO 10094-1:2010ISO 10094-1:2010(E) iv ISO 2010 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing Internat
13、ional Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with I
14、SO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical c
15、ommittees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to th
16、e possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 10094-1 was prepared by Technical Committee ISO/TC 131, Fluid power systems, Subcommittee SC 5, Control products and comp
17、onents. ISO 10094 consists of the following parts, under the general title Pneumatic fluid power Electro-pneumatic pressure control valves: Part 1: Main characteristics to include in the suppliers literature Part 2: Test methods to determine main characteristics to include in the suppliers literatur
18、e BS ISO 10094-1:2010ISO 10094-1:2010(E) ISO 2010 All rights reserved vIntroduction In pneumatic fluid power systems, power is transmitted and controlled through a gas under pressure within a circuit. When it is required to track precisely a variable pressure set point or when precise pressure regul
19、ation is needed, electro-pneumatic continuous pressure control valves can be used. These control valves continuously modulate the pneumatic power of a system in response to a continuous electrical input signal and link the electrical input value to a proportional pressure value. It is therefore nece
20、ssary to know some performance characteristics of these electro-pneumatic continuous pressure control valves in order to determine their suitability. BS ISO 10094-1:2010BS ISO 10094-1:2010INTERNATIONAL STANDARD ISO 10094-1:2010(E) ISO 2010 All rights reserved 1Pneumatic fluid power Electro-pneumatic
21、 pressure control valves Part 1: Main characteristics to include in the suppliers literature 1 Scope This part of ISO 10094 specifies which characteristics of electro-pneumatic continuous pressure control valves are to be included in the suppliers literature. In accordance with ISO 5598, these contr
22、ol valves include electrically modulated pneumatic proportional pressure valves, pressure proportional control valves, and pressure servo-valves (closed loop). NOTE 1 The characteristics of non-electrically modulated pneumatic pressure control valves are specified in ISO 6953-1. NOTE 2 The character
23、istics of electro-pneumatic continuous flow control valves are specified in ISO 10041-1. NOTE 3 This part of ISO 10094 is limited to the characterization of components with an exhaust port to the atmosphere. 2 Normative references The following referenced documents are indispensable for the applicat
24、ion of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 5598, Fluid power systems and components Vocabulary ISO 6953-1, Pneumatic fluid power Compressed air pressure regu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1009412010PNEUMATICFLUIDPOWERELECTROPNEUMATICPRESSURECONTROLVALVESMAINCHARACTERISTICSTOINCLUDEINTHESUPPLIERSLITERATURE

链接地址:http://www.mydoc123.com/p-583166.html