BS IEC 61378-3-2015 Converter transformers Application guide《换流变压器 应用指南》.pdf
《BS IEC 61378-3-2015 Converter transformers Application guide《换流变压器 应用指南》.pdf》由会员分享,可在线阅读,更多相关《BS IEC 61378-3-2015 Converter transformers Application guide《换流变压器 应用指南》.pdf(96页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationConverter transformersPart 3: Application guideBS IEC 61378-3:2015National forewordThis British Standard is the UK implementation of IEC 61378-3:2015.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/14, Power transformers.A list of organization
2、s represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978
3、 0 580 89736 8ICS 29.180Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 28 February 2015. Amendments/corrigenda issued since publicationDate Text affectedBRITISH S
4、TANDARDBS IEC 61378-3:2015IEC 61378-3 Edition 2.0 2015-02 INTERNATIONALSTANDARD NORMEINTERNATIONALE Converter transformers Part 3: Application guide Transformateurs de conversion Partie 3: Guide dapplication INTERNATIONALELECTROTECHNICALCOMMISSION COMMISSIONELECTROTECHNIQUEINTERNATIONALE ICS 29.180
5、ISBN 978-2-8322-2233-1 Registered trademark of the International Electrotechnical Commission Marque dpose de la Commission Electrotechnique Internationale Warning! Make sure that you obtained this publication from an authorized distributor. Attention! Veuillez vous assurer que vous avez obtenu cette
6、 publication via un distributeur agr. 2 IEC 61378-3:2015 IEC 2015 CONTENTS FOREWORD . 6 INTRODUCTION . 8 0.1 General . 8 0.2 Rating data (Clause 5) 8 0.3 Winding configurations (Clause 6) . 8 0.4 Tappings and impedances (Clause 7) 8 0.5 Insulation aspects and dielectric tests (Clause 8) . 9 0.6 Loss
7、es (Clause 9) . 9 0.7 Core and sound aspects (Clause 10) . 9 0.8 Transformer specification (Clause 11) 9 0.9 Short circuit considerations (Clause 12) . 9 0.10 Components (Clause 13) . 10 0.11 Maintenance (Clause 14) . 10 0.12 Monitoring and on-site investigations (Clause 15) 10 0.13 Additional sourc
8、es of information . 10 1 Scope 11 2 Normative references. 11 3 Terms and definitions 11 4 Symbols and abbreviations 11 5 Rating data 12 6 Winding configurations . 13 6.1 General . 13 6.2 Industrial applications . 15 6.2.1 Rectifier . 15 6.2.2 Voltage regulation 16 6.2.3 Autotransformer design 17 6.3
9、 HVDC applications 22 6.3.1 Different types of transformer arrangement . 22 6.3.2 Winding arrangements . 23 6.3.3 Consideration of impedance mutual impedance . 24 7 Tappings and impedances HVDC applications . 25 7.1 Value of impedance . 25 7.2 Variability of impedance 25 8 Insulation aspects and die
10、lectric tests 26 8.1 Hybrid insulation systems 26 8.1.1 General . 26 8.1.2 Hybrid insulation for converter transformers 27 8.2 Dielectric tests 28 8.2.1 General . 28 8.2.2 Dielectric safety margins in long term d.c. and polarity reversal testing . 30 8.2.3 Comments on the dielectric test procedures
11、31 9 Losses 33 9.1 General . 33 9.1.1 General considerations 33 9.1.2 Losses and frequency 34 BS IEC 61378-3:2015IEC 61378-3:2015 IEC 2015 3 9.1.3 Current sharing, losses and hot spot in high current windings . 35 9.1.4 Current harmonics . 35 9.1.5 Transformers with three or more windings wound on t
12、he same core limb . 36 9.1.6 Dual frequency testing of HVDC transformers . 41 9.1.7 Transformers with more than one active part in the same tank 43 9.1.8 Transformers connected to a voltage source converter . 44 9.2 Thermal tests 44 9.2.1 General . 44 9.2.2 Calculation of test currents and losses fo
13、r industrial transformers . 44 9.2.3 Calculation of losses and test currents for HVDC transformers 44 9.2.4 Considerations on the hot spot and limits of the thermal tests . 45 9.2.5 Considerations on temperature rise test of industrial transformers . 45 9.2.6 Tank hot spots in industrial transformer
14、s 46 10 Core and sound aspects 46 10.1 Core . 46 10.1.1 Constructional features 46 10.1.2 Effect of harmonics on transformer active part cores . 47 10.1.3 DC bias voltage effect on main active part cores . 47 10.1.4 Summary about cores 48 10.2 Sound . 48 10.2.1 General . 48 10.2.2 Fundamental consid
15、erations . 49 11 Transformer specification . 50 11.1 General . 50 11.2 Technical specification versus functional specifications 51 11.2.1 General . 51 11.2.2 Technical specifications . 51 11.2.3 Functional specifications 51 11.3 HVDC transformer specifications . 51 11.4 Notes and comments on specifi
16、cation items to be provided individually by purchaser and supplier 52 11.5 Information to be provided by the purchaser or by the system designer 52 11.5.1 General description 52 11.5.2 System data . 52 11.5.3 Environmental data 53 11.5.4 Performance requirements . 53 11.5.5 Testing requirements . 55
17、 11.5.6 Sequence of factory tests . 57 11.5.7 Site tests . 57 11.5.8 Design and construction requirements 58 11.5.9 Auxiliary equipment 58 11.5.10 Availability and measures to minimize service downtime . 60 11.6 Information to be provided by the supplier . 60 11.6.1 General . 60 11.6.2 General descr
18、iption 60 11.6.3 Performance data 60 11.6.4 Supplementary data . 61 11.7 Quality assurance and test program . 63 11.8 Availability and measures to minimize service downtime 63 BS IEC 61378-3:2015 4 IEC 61378-3:2015 IEC 2015 12 Short circuit considerations 63 13 Components 67 13.1 On-load tap-changer
19、s 67 13.1.1 General . 67 13.1.2 Converters for industrial applications 67 13.1.3 Converter for HVDC applications 68 13.2 Valve-side bushings 68 13.2.1 General . 68 13.2.2 Station layout . 69 13.2.3 Technical considerations 69 13.2.4 Bushing types 69 13.2.5 Testing 69 14 Maintenance 71 14.1 General .
20、 71 14.2 Oil 72 14.2.1 General . 72 14.2.2 Oil quality and transformer quality indicators . 73 14.3 Insulation quality . 73 14.3.1 General . 73 14.3.2 Oil sampling requirements 74 14.3.3 Oil tests . 75 14.3.4 Oil handling, storage and treatment 76 14.3.5 Oil preservation systems 76 14.4 Tap-changers
21、 77 14.5 Accessories and fittings . 79 15 Monitoring . 79 15.1 General . 79 15.2 Transformer condition assessment in service . 80 15.3 Types of monitor . 80 15.3.1 General . 80 15.3.2 Oil condition monitoring 80 15.3.3 Off-line condition assessment . 81 15.3.4 On and off-line monitors . 81 15.3.5 Ex
22、pert systems 83 15.3.6 Fingerprinting. 83 15.4 Monitoring summary 84 16 Design review of converter transformers 84 16.1 General . 84 16.2 Scheduling and confidentiality . 85 16.3 Subject for design review 86 16.3.1 General . 86 16.3.2 System information 86 16.3.3 Environmental Information 87 16.3.4
23、Transformer specific requirements 87 Bibliography . 91 Figure 1 Bridge connection for six-pulse arrangement . 14 BS IEC 61378-3:2015IEC 61378-3:2015 IEC 2015 5 Figure 2 Bridge connection for twelve-pulse arrangement . 14 Figure 3 Transformer connections star-delta and star-star or alternatively, del
24、ta-delta and delta-star to give a 30 electrical degree separation between the valve-side voltages 14 Figure 4 15 phase shifting is preferably realized by extended delta or zigzag connection 15 Figure 5 Double-star connection . 15 Figure 6 Typical connection of transductors 16 Figure 7 Autotransforme
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSIEC6137832015CONVERTERTRANSFORMERSAPPLICATIONGUIDE 换流 变压器 应用 指南 PDF

链接地址:http://www.mydoc123.com/p-583007.html