BS IEC 61084-1-2017 Cable trunking systems and cable ducting systems for electrical installations General requirements《电气装置用电缆中继系统和电缆管道系统 通用要求》.pdf
《BS IEC 61084-1-2017 Cable trunking systems and cable ducting systems for electrical installations General requirements《电气装置用电缆中继系统和电缆管道系统 通用要求》.pdf》由会员分享,可在线阅读,更多相关《BS IEC 61084-1-2017 Cable trunking systems and cable ducting systems for electrical installations General requirements《电气装置用电缆中继系统和电缆管道系统 通用要求》.pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、Cable trunking systems and cable ducting systems for electrical installationsPart 1: General requirementsBS IEC 61084-1:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis British Standard is the UK implementation of IEC 61084-1:2017.The UK part
2、icipation in its preparation was entrusted to TechnicalCommittee PEL/213, Cable management.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible fo
3、r its correct application. The British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 89532 6ICS 29.060.01; 29.120.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of theStand
4、ards Policy and Strategy Committee on 30 April 2017.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS IEC 61084-1:2017_ _ 2 IEC 61084-1:2017 IEC 2017 CONTENTS FOREWORD . 5 1 Scope 7 2 Normative references 7 3 Terms and definitions 7 4 General requirements 12 5 Genera
5、l conditions for tests . 12 6 Classification . 13 6.1 According to material 13 6.2 According to resistance to impact for installation and application 13 6.2.1 CTS/CDS for impact 0,5 J 13 6.2.2 CTS/CDS for impact 0,7 J 13 6.2.3 CTS/CDS for impact 1 J . 13 6.2.4 CTS/CDS for impact 2 J . 13 6.2.5 CTS/C
6、DS for impact 5 J . 13 6.2.6 CTS/CDS for impact 10 J . 13 6.2.7 CTS/CDS for impact 20 J . 13 6.3 According to temperatures as given in Table 1, Table 2 and Table 3 below . 13 6.4 According to resistance to flame propagation 14 6.4.1 Flame propagating CTS/CDS . 14 6.4.2 Non-flame propagating CTS/CDS
7、14 6.5 According to electrical continuity characteristic . 14 6.5.1 CTS/CDS with electrical continuity characteristic . 14 6.5.2 CTS/CDS without electrical continuity characteristic 14 6.6 According to electrical insulating characteristic . 14 6.6.1 CTS/CDS without electrical insulating characterist
8、ic 14 6.6.2 CTS/CDS with electrical insulating characteristic . 14 6.7 According to degrees of protection provided by enclosure according to IEC 60529:1989 14 6.7.1 According to protection against ingress of solid foreign objects . 14 6.7.2 According to protection against ingress of water 14 6.7.3 A
9、ccording to protection against access to hazardous parts 14 6.8 According to protection against corrosive or polluting substances . 14 6.9 According to the system access cover retention 14 6.9.1 CTS/CDS access cover, which can be opened without a tool . 14 6.9.2 CTS/CDS access cover, which can only
10、be opened with a tool 14 7 Marking and documentation . 14 8 Dimensions 17 9 Construction 17 9.1 Sharp edges . 17 9.2 Apparatus mounting 17 9.3 Means for protective separation and/or retention 17 9.4 Mechanical connections 18 9.5 Accessible conductive parts 19 9.6 Equipotential bonding . 20 9.7 Acces
11、s to live parts . 20 9.8 Inlet openings . 21 BS IEC 61084-1:2017IEC 61084-1:2017 IEC 2017 3 9.9 Membranes . 21 9.10 Cable restrainer 21 9.11 Cable anchorage . 22 10 Mechanical properties 23 10.1 Mechanical strength 23 10.2 Cable support test . 23 10.3 Impact test 23 10.3.1 Impact test for storage an
12、d transport . 23 10.3.2 Impact test for installation and application . 24 10.4 Linear deflection test. 24 10.5 External load test 24 10.5.1 Fixing test for apparatus mounting of socket outlets 24 10.5.2 Fixing test for apparatus mounting other than socket outlets 25 10.6 System access cover retentio
13、n 25 11 Electrical properties . 26 11.1 Electrical continuity . 26 11.1.1 General . 26 11.1.2 Preparation and conditioning . 26 11.1.3 Electrical impedance tests . 26 11.2 Electrical insulation . 28 11.2.1 Solid insulation 28 11.2.2 Conditioning and preparation . 28 11.2.3 Insulation resistance test
14、 . 29 11.2.4 Dielectric strength test . 29 12 Thermal properties 29 12.1 Resistance to heat 29 12.1.1 General . 29 12.1.2 Test for non-metallic or composite system components necessary to retain current-carrying parts in position 29 12.1.3 Test for non-metallic or composite system components not nec
15、essary to retain current-carrying parts in position 30 13 Fire hazard 30 13.1 Reaction to fire . 30 13.1.1 Initiation of fire 30 13.1.2 Contribution to fire . 31 13.1.3 Spread of fire . 31 13.1.4 Additional reaction to fire characteristics . 32 13.2 Resistance to fire 32 14 External influences 32 14
16、.1 Degree of protection provided by enclosure 32 14.1.1 General . 32 14.1.2 Protection against ingress of solid foreign objects . 32 14.1.3 Protection against ingress of water 33 14.1.4 Protection against access to hazardous parts 33 14.2 Protection against corrosive or polluting substances . 33 15
17、Electromagnetic compatibility 33 Annex A (informative) Types of cable trunking systems (CTS) and cable ducting systems (CDS) 42 Annex B (normative) CTS/CDS IK code . 44 BS IEC 61084-1:2017 4 IEC 61084-1:2017 IEC 2017 Bibliography 45 Figure 1 Types and application of trunking systems (CTS) and ductin
18、g systems (CDS) . 34 Figure 2 Example of impact test apparatus 35 Figure 3 Arrangement for test for resistance to flame propagation . 36 Figure 4 Enclosure for test for resistance to flame propagation 37 Figure 5 Ball pressure test apparatus . 37 Figure 6 Electrical impedance tests arrangement . 39
19、Figure 7 Examples of membranes and grommets . 39 Figure 8 Typical apparatus for testing the resistance of cable anchorage to pull force 40 Figure 9 Typical apparatus for testing the resistance of cable anchorage to twist force . 41 Figure 10 Piston for durability of marking test 41 Table 1 Minimum s
20、torage and transport temperature . 13 Table 2 Minimum installation and application temperature . 13 Table 3 Maximum application temperature . 13 Table 4 Torque values for the test of screwed connections 19 Table 5 Forces and torques to be applied to cable anchorage 23 Table 6 Impact test values . 24
21、 Table A.1 Types of CTS and CDS for wall and ceiling installation 42 Table A.2 Types of CTS and CDS for floor installation . 42 Table A.3 Types of CTS and CDS for installation between two opposite surfaces . 43 BS IEC 61084-1:2017IEC 61084-1:2017 IEC 2017 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION
22、_ CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS Part 1: General requirements FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees).
23、The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Spec
24、ifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organization
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSIEC6108412017CABLETRUNKINGSYSTEMSANDCABLEDUCTINGSYSTEMSFORELECTRICALINSTALLATIONSGENERALREQUIREMENTS

链接地址:http://www.mydoc123.com/p-582977.html