BS EN 62311-2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)《电磁场用电子和电气设备关于人体照射限制的评估(0Hz-300.pdf
《BS EN 62311-2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)《电磁场用电子和电气设备关于人体照射限制的评估(0Hz-300.pdf》由会员分享,可在线阅读,更多相关《BS EN 62311-2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)《电磁场用电子和电气设备关于人体照射限制的评估(0Hz-300.pdf(76页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 62311:2008Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz 300 GHz)ICS 13.280; 97.030g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36
2、g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 62311:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 May 2008 BSI 2008ISBN 978 0 580 53575 8National forewordThis British Standard is the UK impleme
3、ntation of EN 62311:2008. It was derived by CENELEC from IEC 62311:2007. It supersedes BS EN 50392:2004 which is withdrawn.The CENELEC common modifications have been implemented at the appropriate places in the text and are indicated by tags (e.g. ).The UK participation in its preparation was entrus
4、ted to Technical Committee GEL/106, Human exposure to low frequency and high frequency electromagnetic radiation.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract.
5、Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments/corrigenda issued since publicationDate CommentsEUROPEAN STANDARD EN 62311 NORME EUROPENNE EUROPISCHE NORM January 2008 CENELEC European Committee for Electro
6、technical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No
7、. EN 62311:2008 E ICS 97.030 Supersedes EN 50392:2004English version Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) (IEC 62311:2007, modified) Evaluation des quipements lectroniques et lectriques en relation avec l
8、es restrictions dexposition humaine aux champs lectromagntiques (0 Hz - 300 GHz) (CEI 62311:2007, modifie) Bewertung von elektrischen und elektronischen Einrichtungen in Bezug auf Begrenzungen der Exposition von Personen in elektromagnetischen Feldern (0 Hz - 300 GHz) (IEC 62311:2007, modifiziert) T
9、his European Standard was approved by CENELEC on 2007-12-04. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical r
10、eferences concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENEL
11、EC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, I
12、celand, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 62311:2008 2 Foreword The text of document 106/129/FDIS, future edition 1 of IEC 62311, prepared by IEC TC 106,
13、Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure, was submitted to the IEC-CENELEC parallel vote. A draft amendment, prepared by the Technical Committee CENELEC TC 106X, Electromagnetic fields in the human environment, was submitted to the Un
14、ique Acceptance Procedure. The combined texts of IEC 62311:2007 and the draft amendment prAA were approved by CENELEC as EN 62311 on 2007-12-04. This European Standard supersedes EN 50392:2004. The following dates were fixed: latest date by which the EN has to be implemented at national level by pub
15、lication of an identical national standard or by endorsement (dop) 2009-01-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-01-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 62311:2007 was a
16、pproved by CENELEC as a European Standard with agreed common modifications. _ 3 EN 62311:2008 CONTENTS 1 Scope and object5 2 Normative references .5 3 Terms and definitions .5 4 Compliance criteria.9 5 Assessment methods9 6 Evaluation of compliance to limits .10 7 Applicability of compliance assessm
17、ent methods.11 7.1 General .11 7.2 Generic procedure for assessment of equipment 13 8 Sources with multiple frequencies .16 8.1 Introduction .16 8.2 Frequency range from 1 Hz 10 MHz (ICNIRP-based) .16 8.2.1 Frequency domain assessment 16 8.2.2 Time domain assessment.18 8.3 Frequency range from 100 k
18、Hz 300 GHz (ICNIRP-based)20 8.4 Frequency range from 0 kHz 5 MHz (IEEE-based) .21 8.4.1 Frequency domain assessment 21 8.4.2 Time domain assessment.21 8.5 Frequency range from 3 kHz 300 GHz (IEEE-based) .22 9 Assessment report22 9.1 General .22 9.2 Items to be recorded in the assessment report .23 9
19、.2.1 Assessment method.23 9.2.2 Presentation of the results23 9.2.3 Equipment using external antennas 23 10 Information to be supplied with the equipment.23 Annex A (informative) Field calculation.24 Annex B (informative) SAR compliance assessment 29 Annex C (informative) Information for numerical m
20、odelling31 Annex D (informative) Measurements of physical properties and body currents .60 Annex E (informative) Specific absorption rate (SAR) 64 Annex F (informative) Measurement of E and H field.66 Annex G (informative) Source modelling69 Annex ZA (normative) Normative references to international
21、 publications with their corresponding European publications73 Bibliography .72 Figure 1 Assessment flowchart.15 Figure 2 Schematic of “weighting circuit” 18 Figure 3 Dependency on frequency of the reference levels V plotted with smoothing edges .18 EN 62311:2008 4 Figure 4 Transfer function A .19 F
22、igure A.1 Geometry of antenna with largest linear dimension D .24 Figure A.2 Current element Idlsin( t) at the origin of spherical coordinate system25 Figure A.3 Ratio of E2, H2, and E H field components.26 Figure A.4 Ratio of E H field components for three typical antennas .27 Figure A.5 Far-field
23、= straight line, radiated near-field = lower line specific energy absorption is the time integral of specific energy absorption rate 3.27 specific absorption rate SAR power absorbed by (dissipated in) an incremental mass contained in a volume element of biological tissue when exposure to an electrom
24、agnetic field occurs. SAR is expressed in the unit watt per kilogram (W/kg). SAR is used as a measure of whole-body exposure as well as localised exposure 3.28 exposure assessment for purposes of this standard the term exposure assessment means conformity assessment with respect to applicable exposu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN623112008ASSESSMENTOFELECTRONICANDELECTRICALEQUIPMENTRELATEDTOHUMANEXPOSURERESTRICTIONSFORELECTROMAGNETICFIELDS0HZ300GHZ

链接地址:http://www.mydoc123.com/p-578330.html