BS EN 61970-1-2006 Energy management system application program interface (EMS-API) - Guidelines and general requirements《能量管理系统应用程序接口(EMS-API) 指南和一般要求》.pdf
《BS EN 61970-1-2006 Energy management system application program interface (EMS-API) - Guidelines and general requirements《能量管理系统应用程序接口(EMS-API) 指南和一般要求》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61970-1-2006 Energy management system application program interface (EMS-API) - Guidelines and general requirements《能量管理系统应用程序接口(EMS-API) 指南和一般要求》.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58(EMS-API) Part 1: Guidelines and general requirements The European Standard EN 61970-1:2006 has the
2、 status of a British StandardICS 33.200Energy management system application program interface BRITISH STANDARDBS EN61970-1:2006BS EN 61970-1:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2006 BSI 2006ISBN 0 580 48967 1Cross-refe
3、rencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British
4、 Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations.Summary of pagesThis document comprises a front c
5、over, an inside front cover, the EN title page, pages 2 to 41 and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsA list of organizations represented on this committee can be obtaine
6、d on request to its secretary. present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.National forewordThis British
7、 Standard is the official English language version of EN 61970-1:2006. It is identical with IEC 61970-1:2005.The UK participation in its preparation was entrusted to Technical Committee PEL/57, Power systems management and associated information exchange, which has the responsibility to: aid enquire
8、rs to understand the text;EUROPEAN STANDARD EN 61970-1 NORME EUROPENNE EUROPISCHE NORM May 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B
9、- 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61970-1:2006 E ICS 33.200 English version Energy management system application program interface (EMS-API) Part 1: Guidelines and general requirements (IEC 61970
10、-1:2005) Interface de programmation dapplication pour systme de gestion dnergie (EMS-API) Partie 1: Lignes directrices et exigences gnrales (CEI 61970-1:2005) Schnittstelle der Anwendungsprotokolle von Energieverwaltungssystemen (EMS-API) Teil 1: Leitfaden und allgemeine Anforderungen (IEC 61970-1:2
11、005) This European Standard was approved by CENELEC on 2005-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliograph
12、ical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a
13、 CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Icela
14、nd, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 57/777/FDIS, future edition 1 of IEC 61970-1, prepared by IEC TC 57, Power systems manage
15、ment and associated information exchange, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61970-1 on 2005-12-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by
16、 endorsement (dop) 2006-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-12-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61970-1:2005 was approved by CENELEC as a European Standard with
17、out any modification. _ EN 61970-1:2006 2 3 EN 61970-1:2006 CONTENTS INTRODUCTION 5 1 Scope 6 2 Normative References 6 3 Terms and definitions .6 4 System integration7 4.1 Integration scenarios .7 4.2 Integration considerations7 4.3 Component-based interfaces .10 4.4 Relationship to IEC 61968 series
18、 of standards.11 5 EMS-API reference model 12 5.1 General.12 5.2 Control center environment13 5.3 Application context 13 5.4 Application 13 5.5 Component14 5.6 Legacy application and wrappers.14 5.7 Component model .15 5.8 Component container 16 5.9 Component adapter .16 5.10 Component execution sys
19、tem 17 5.11 Middleware17 5.12 Communication profiles .18 5.13 Reference model examples18 6 EMS-API standards 20 6.1 General.20 6.2 CIM (IEC 61970-3XX)20 6.3 CIS (IEC 61970-4XX) 23 6.4 CIS technology mappings (IEC 61970-5XX) .24 7 General expected infrastructure functionality 24 7.1 General.24 7.2 Co
20、mponent Container25 7.3 Middleware26 7.4 Communication Profile Services 26 7.5 Utility-specific services 27 Annex A (informative) Component models28 Annex B (informative) Typical applications and functions .32 Annex C (informative) Utility issues with standard component models 37 Annex D (informativ
21、e) Examples of component execution systems and middleware products .39 Annex ZA (normative) Normative references to international publications with their corresponding European publications 41 Bibliography .40 EN 61970-1:2006 4 Figure 1 EMS-API Reference Model.12 Figure 2 EMS using EMS-API component
22、 standard interfaces 19 Table 1 Benefits of Component-based Interfaces .11 Table 2 Examples of EMS application contexts.13 Table B.1 Typical applications and functions 32 5 EN 61970-1:2006 INTRODUCTION This standard is part of the IEC 61970 series that defines application program interfaces (APIs) f
23、or an energy management system (EMS). This standard is based to a large extent upon the work of the EPRI Control Center API (CCAPI) research project (RP-3654-1). The principle objectives of the EPRI CCAPI project are to: reduce the cost and time needed to add new applications to an EMS or other syst
24、em1; protect the investment in existing applications that are working effectively; improve the capability to exchange information between disparate systems both within and external to the control center environment. The technical approach is to provide an integration framework for interconnecting ex
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6197012006ENERGYMANAGEMENTSYSTEMAPPLICATIONPROGRAMINTERFACEEMSAPIGUIDELINESANDGENERALREQUIREMENTS

链接地址:http://www.mydoc123.com/p-577989.html