BS EN 61566-1998 Measurement of exposure to radio-frequency electromagnetic fields - Field strength in the frequency range 100 kHz to 1 GHz《射频电磁场辐照测量 频率在100kHz和1GHz间的场强》.pdf
《BS EN 61566-1998 Measurement of exposure to radio-frequency electromagnetic fields - Field strength in the frequency range 100 kHz to 1 GHz《射频电磁场辐照测量 频率在100kHz和1GHz间的场强》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61566-1998 Measurement of exposure to radio-frequency electromagnetic fields - Field strength in the frequency range 100 kHz to 1 GHz《射频电磁场辐照测量 频率在100kHz和1GHz间的场强》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 61566:1998 IEC61566: 1997 Measurement of exposure to radio-frequency electromagnetic fields Field strength in thefrequency range100kHz to 1GHz The European Standard EN 61566:1997 has the status of a British Standard ICS33.100BSEN 61566:1998 This British Standard, having been p
2、repared under the directionof the Electrotechnical Sector Board, was published underthe authority of the Standards Board and comes intoeffect on 15 June 1998 BSI 03-1999 ISBN 0 580 28427 1 National foreword This British Standard is the English language version of EN61566:1997. It is identical with I
3、EC61566:1997. The UK participation in its preparation was entrusted to Technical Committee EPL/103, Transmitting equipment for radiocommunication, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the i
4、nterpretation, or proposals for change, and keep theUKinterests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. From 1 January 1997, all IEC publication
5、s have the number60000 added to the old number. For instance, IEC27-1 has been renumbered as IEC60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references Attention is drawn to the fact that CE
6、N and CENELEC Standards normally include an annex which lists normative references to international publications with their corresponding European publications. The British Standards which implement these international or European publications may be found in the BSI Standards Catalogue under the se
7、ction entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application.
8、Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theEN title page, pages 2 to 16, an inside back cover and a back cover. This standard has been updated (see cop
9、yright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSEN 61566:1998 BSI 03-1999 i Contents Page National foreword Inside front cover Foreword 2 Text of EN 61566 3ii b
10、lankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61566 July 1997 ICS 33.100 Descriptors: Radiocommunications, radio equipment, transmitters, measurements, electromagnetic fields, field strength, safety, exposure, accident prevention, work safety, measuring instruments, verification, hazards
11、English version Measurement of exposure to radio-frequency electromagnetic fields Field strength in the frequencyrange100kHz to 1GHz (IEC 61566:1997) Mesure de lexposition aux champs lectromagntiques radiofrquence Intensit du champ dans la gamme de frquences entre100kHz et 1GHz (CEI 61566:1997) Mess
12、ung der Belastung durch hochfrequente elektromagnetische Felder Feldstrke im Frequenzbereich 100kHz bis 1GHz (IEC 61566:1997) This European Standard was approved by CENELEC on 1997-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for
13、 giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three offic
14、ial versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical commi
15、ttees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Eur
16、opisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1997 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN61566:1997 EEN61566:1997 BSI 03-1999 2 Foreword The text of document 103/1/FD
17、IS, future edition 1 of IEC61566, prepared by IEC TC103, Transmitting equipment for radiocommunication, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN61566 on 1997-07-01. The following dates were fixed: Annexes designated “normative” are part of the body of the stan
18、dard. Annexes designated “informative” are given for information only. In this standard, Annex ZA is normative and Annex A andAnnex B are informative. Annex ZA has been added by CENELEC. Endorsement notice The text of the International Standard IEC 61566:1997 was approved by CENELEC as a European St
19、andard without any modification. Contents Page Foreword 2 Introduction 3 1 Scope 3 2 Normative reference 3 3 Definitions 3 4 General technical requirements 5 4.1 General considerations 5 4.2 Measurements in exposure space 5 4.3 Electromagnetic field strength 5 4.4 Interference patterns 5 4.5 Radiati
20、on leakage 6 4.6 Reactive near-field 6 4.7 Radiating near-field 6 4.8 Summary of measurement problems 6 4.9 Safety precautions 7 5 Measuring instrument requirements 7 Page 5.1 General 7 5.2 Electrical performance requirements 7 5.3 Miscellaneous requirements 8 5.4 Physical characteristics 8 5.5 Inst
21、rument types 8 5.6 Diode instruments 8 5.7 Bolometric type 9 5.8 Thermocouple type 9 5.9 Spurious responses 9 5.10 Calibration of instruments 11 6 Measurement 11 6.1 Preliminary procedures 11 6.2 Measurement procedures 14 Annex A (informative) Summary of the main restrictions giveninthe INIRC guidel
22、ines of1988that arerelevant to the frequency rangecovered bythisInternational Standard 16 Annex B (informative) Bibliography 16 Annex ZA (normative) Normative referencestointernationalpublications withtheircorrespondingEuropean publications Inside back cover Figure 1 Basic components of an electroma
23、gneticfield instrument 15 Table 1 Examples of antennas for verticalpolarization for frequencies up to 30 MHz 13 Table 2 Examples of antennas for horizontal polarization, for frequencies up to 30 MHz 13 Table 3 Examples of antennas for frequencies above 30 MHz 13 Table 4 Mean radiated power as a func
24、tion ofrated power for various types and classes ofAMtransmission 13 Table A.1 Occupational exposure limits 16 Table A.2 Public exposure limits 16 latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 1998-04-01 l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN615661998MEASUREMENTOFEXPOSURETORADIOFREQUENCYELECTROMAGNETICFIELDSFIELDSTRENGTHINTHEFREQUENCYRANGE100KHZTO1GHZ

链接地址:http://www.mydoc123.com/p-577577.html