BS EN 61557-6-2007 Electrical safety in low voltage distribution systems up to 1000 V a c and 1500 V d c Equipment for testing measuring or monitoring of protective measures Effec .pdf
《BS EN 61557-6-2007 Electrical safety in low voltage distribution systems up to 1000 V a c and 1500 V d c Equipment for testing measuring or monitoring of protective measures Effec .pdf》由会员分享,可在线阅读,更多相关《BS EN 61557-6-2007 Electrical safety in low voltage distribution systems up to 1000 V a c and 1500 V d c Equipment for testing measuring or monitoring of protective measures Effec .pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 61557-6:2007Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systemsThe European Standard EN 6
2、1557-6:2007 has the status of a British StandardICS 17.220.20; 29.080.01; 29.240.01g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61557-6:200
3、7This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 December 2007 BSI 2007ISBN 978 0 580 54796 6National forewordThis British Standard is the UK implementation of EN 61557-6:2007. It is identical to IEC 61557-6:2007. It supersedes BS EN 61557
4、-6:1998, which will be withdrawn on 1 October 2010.The UK participation in its preparation was entrusted to Technical Committee PEL/85, Measuring equipment for electrical and electromagnetic quantities.A list of organizations represented on this committee can be obtained on request to its secretary.
5、This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61
6、557-6 NORME EUROPENNE EUROPISCHE NORM November 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of
7、 exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61557-6:2007 E ICS 17.220.20; 29.080.01; 29.240.01 Supersedes EN 61557-6:1998English version Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testin
8、g, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems (IEC 61557-6:2007) Scurit lectrique dans les rseaux de distribution basse tension de 1 000 V c.a. et 1 500 V c.c. - Dispositifs de contrle, de mesure ou de surveillanc
9、e de mesures de protection - Partie 6: Efficacit des dispositifs courant rsiduel (DCR) dans les rseaux TT, TN et IT (CEI 61557-6:2007) Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V - Gerte zum Prfen, Messen oder berwachen von Schutzmanahmen - Teil 6: Wirksamkeit von F
10、ehlerstrom-Schutzeinrichtungen (RCD) in TT-, TN- und IT-Systemen (IEC 61557-6:2007) This European Standard was approved by CENELEC on 2007-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status
11、of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A
12、version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cypru
13、s, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 61557-6:2007 2 Foreword The
14、 text of document 85/279A/CDV, future edition 2 of IEC 61557-6, prepared by IEC TC 85, Measuring equipment for electrical and electromagnetic quantities, was submitted to the IEC-CENELEC parallel Unique Acceptance Procedure and was approved by CENELEC as EN 61557-6 on 2007-10-01. This European Stand
15、ard supersedes EN 61557-6:1998. The following changes were made with respect to EN 61557-6:1998: title and scope complemented; definitions complemented; revision of requirements; “tripping tests“ and “non-tripping tests“ subclauses complemented; “operating instructions“ subclause complemented; addit
16、ion of Annex A. This standard is to be used in conjunction with EN 61557-1. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-07-01 latest date by which the national standa
17、rds conflicting with the EN have to be withdrawn (dow) 2010-10-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61557-6:2007 was approved by CENELEC as a European Standard without any modification. _ 3 EN 61557-6:2007 CONTENTS 1 Scope 4 2 Normati
18、ve references .4 3 Terms and definitions .4 4 Requirements.5 5 Marking and operating instructions .8 5.1 Marking.8 5.2 Operating instructions .8 6 Tests8 Annex A (normative) Measuring equipment for residual current protective devices (RCDs) of type B 10 Annex ZA (normative) Normative references to i
19、nternational publications with their corresponding European publications .13 Bibliography .12 Table 1 Calculation of operating uncertainty.6 EN 61557-6:2007 4 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V a.c. AND 1500 V d.c. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PRO
20、TECTIVE MEASURES Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems 1 Scope This part of IEC 61557 specifies the requirements for measuring equipment applied to the testing of the effectiveness of protective measures by regular disconnections of residual current protect
21、ive devices (RCD) in TT, TN and IT systems. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any ame
22、ndments) applies. IEC/TR 60755, General requirements for residual current operated protective devices IEC 60947-2, Low-voltage switchgear and controlgear Part 2: Circuit-breakers IEC 61008 (all parts), Residual current operated circuit-breakers without integral overcurrent protection for household a
23、nd similar uses (RCCBs) IEC 61009 (all parts), Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) IEC 61010-1:2001, Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requiremen
24、ts IEC 61557-1:2007, Electrical safety in low voltage distribution systems up to 1 000 V a.c and 1 500 V d.c Equipment for testing, measuring or monitoring of protective measures Part 1: General requirements 3 Terms and definitions For the purposes of this document, the definitions given in IEC 6155
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6155762007ELECTRICALSAFETYINLOWVOLTAGEDISTRIBUTIONSYSTEMSUPTO1000VACAND1500VDCEQUIPMENTFORTESTINGMEASURINGORMONITORINGOFPROTECTIVEMEASURESEFFECPDF

链接地址:http://www.mydoc123.com/p-577556.html