BS EN 61290-10-4-2007 Optical amplifiers - Test methods - Multichannel parameters - Interpolated source subtraction method using an optical spectrum analyzer《光学放大器 试验方法 多道参数 使用光谱分析.pdf
《BS EN 61290-10-4-2007 Optical amplifiers - Test methods - Multichannel parameters - Interpolated source subtraction method using an optical spectrum analyzer《光学放大器 试验方法 多道参数 使用光谱分析.pdf》由会员分享,可在线阅读,更多相关《BS EN 61290-10-4-2007 Optical amplifiers - Test methods - Multichannel parameters - Interpolated source subtraction method using an optical spectrum analyzer《光学放大器 试验方法 多道参数 使用光谱分析.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Interpolated source subtraction method using an optical spectrum analyzerThe European Standard EN 6
2、1290-10-4:2007 has the status of a British StandardICS 33.180.30Optical amplifiers Test methods Part 10-4: Multichannel parameters BRITISH STANDARDBS EN 61290-10-4:2007BS EN 61290-10-4:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 Se
3、ptember 2007 BSI 2007ISBN 978 0 580 56242 6Amendments issued since publicationAmd. No. Date CommentsThis publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity fro
4、m legal obligations. National forewordThis British Standard is the UK implementation of EN 61290-10-4:2007. It is identical to IEC 61290-10-4:2007.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/3, Fibre optic systems and acti
5、ve devices.A list of organizations represented on this committee can be obtained on request to its secretary.EUROPEAN STANDARD EN 61290-10-4 NORME EUROPENNE EUROPISCHE NORM July 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europ
6、isches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61290-10-4:2007 E ICS 33.180.30 English version Optical amplifiers - Test
7、methods - Part 10-4: Multichannel parameters - Interpolated source subtraction method using an optical spectrum analyzer (IEC 61290-10-4:2007) Amplificateurs optiques - Mthodes dessais - Partie 10-4: Paramtres canaux multiples - Mthode par soustraction de la source interpole en utilisant un analyseu
8、r de spectre optique (CEI 61290-10-4:2007) Prfverfahren fr Lichtwellenleiter-Verstrker - Teil 10-4: Mehrkanal-Parameter - Quellen-Interpolations- und Subtraktionsverfahren unter Verwendung eines optischen Spektralanalysators (IEC 61290-10-4:2007) This European Standard was approved by CENELEC on 200
9、7-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be
10、obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the
11、Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembour
12、g, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 61290-10-4:2007 2 Foreword The text of document 86C/724/CDV, future edition 1 of IEC 61290-10-4, prepared by SC 86C, Fibre optic systems and active devices, of IEC
13、TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel Unique Acceptance Procedure and was approved by CENELEC as EN 61290-10-4 on 2007-06-01. This standard is to be used in conjunction with EN 61291-1:2006. The following dates were fixed: latest date by which the EN has to be implemented at
14、 national level by publication of an identical national standard or by endorsement (dop) 2008-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-06-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standar
15、d IEC 61290-10-4:2007 was approved by CENELEC as a European Standard without any modification. 3 EN 61290-10-4:2007 CONTENTS INTRODUCTION.4 1 Scope and object5 2 Normative references .5 3 Abbreviated terms 6 4 Apparatus.6 5 Test sample .7 6 Procedure 8 6.1 Calibration.8 6.1.1 Calibration of optical
16、bandwidth8 6.1.2 Calibration of OSA power correction factor .9 6.2 Measurement 10 6.3 Calculation 11 7 Test results 11 Annex A (normative) Limitations of the interpolated source subtraction technique due to source spontaneous emission .12 Annex ZA (normative) Normative references to international pu
17、blications with their corresponding European publications17 Bibliography .16 Figure 1 Apparatus for gain and noise figure measurement.6 Figure A.1 DI subtraction error as a function of source spontaneous emission level.13 Figure A.2 Spectral plot showing additive higher noise level from spontaneous
18、emission of individual laser sources and broadband multiplexer.15 Figure A.3 Significantly reduced spontenous emmision using wavelength selective multiplexer15 EN 61290-10-4:2007 4 INTRODUCTION This International Standard is devoted to the subject of optical amplifiers. The technology of optical amp
19、lifiers is still rapidly evolving, hence amendments and new additions to this standard can be expected. 5 EN 61290-10-4:2007 OPTICAL AMPLIFIERS TEST METHODS Part 10-4: Multichannel parameters Interpolated source subtraction method using an optical spectrum analyzer 1 Scope and object This part of IE
20、C 61290 applies to all commercially available optical amplifiers (OAs) and optically amplified subsystems. It applies to OAs using optically pumped fibres (OFAs based on either rare-earth doped fibres or on the Raman effect), semiconductor optical amplifiers (SOAs) and waveguides (POWA). The object
21、of this standard is to establish uniform requirements for accurate and reliable measurements, by means of the interpolated source subtraction method using an optical spectrum analyzer. The following OA parameters, as defined in Clause 3 of IEC 61291-1, are determined: channel gain, and channel signa
22、l-spontaneous noise figure. This method is called interpolated source subtraction (ISS) because the amplified spontaneous emission (ASE) at each channel is obtained by interpolating from measurements at a small wavelength offset around each channel. To minimize the effect of source spontaneous emiss
23、ion, the effect of source noise is subtracted from the measured noise. The accuracy of the ISS technique degrades at high input power level due to the spontaneous emission from the laser source(s). Annex A provides guidance on the limits of this technique for high input power. An additional source o
24、f inaccuracy is due to interpolation error. Annex A provides guidance on the magnitude of interpolation error for a typical amplifier ASE versus wavelength characteristic. NOTE 1 All numerical values followed by () are suggested values for which the measurement is assured. Other values may be accept
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN612901042007OPTICALAMPLIFIERSTESTMETHODSMULTICHANNELPARAMETERSINTERPOLATEDSOURCESUBTRACTIONMETHODUSINGANOPTICALSPECTRUMANALYZER

链接地址:http://www.mydoc123.com/p-577254.html