BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf
《BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61169-19-2011 Radio-frequency connectors Sectional specification Radio frequency coaxial connectors of type SSMB《射频连接器 分规范 SSMB型射频同轴连接器》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationRadio-frequency connectorsPart 19: Sectional specification Radio frequency coaxial connectors of type SSMBBS EN 61169-19:2011National forewordThis British Standard is the UK impl
2、ementation of EN 61169-19:2011. It is identical to IEC 61169-19:2011. It supersedes DD IEC/PAS 61169-19:2009,which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communicat
3、ion and signalling.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011 ISBN 978 0 580 64923 3 ICS 33.120.
4、30Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2011.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61169-19:2011E
5、UROPEAN STANDARD EN 61169-19 NORME EUROPENNE EUROPISCHE NORM March 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC
6、 - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61169-19:2011 E ICS 33.120.30 English version Radio-frequency connectors - Part 19: Sectional specification - Radio frequency coaxial connectors of type SSMB (IEC 61169-19:2011) Connecteurs
7、 pour frquences radiolectriques - Partie 19: Spcification intermdiaire - Connecteurs coaxiaux pour frquences radiolectriques de type SSMB (CEI 61169-19:2011) Hochfrequenz-Steckverbinder - Teil 19: Rahmenspezifikation - Hochfrequenz-Koaxial-Steckverbinder des Typs SSMB (IEC 61169-19:2011) This Europe
8、an Standard was approved by CENELEC on 2011-03-03. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
9、concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member
10、into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ic
11、eland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 61169-19:2011EN 61169-19:2011 - 2 - Foreword The text of document 46F/138/CDV, future edition 1 of IEC 61169-1
12、9, prepared by SC 46F, R.F. and microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-19 on 2011-03-03. Attention is drawn t
13、o the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by public
14、ation of an identical national standard or by endorsement (dop) 2011-12-03 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-03-03 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61169-19:2011 was a
15、pproved by CENELEC as a European Standard without any modification. _ BS EN 61169-19:2011- 3 - EN 61169-19:2011 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the applicat
16、ion of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/
17、HD applies. Publication Year Title EN/HD Year IEC 61169-1 A1 A2 1992 1996 1997 Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods EN 61169-1 A1 A2 1994 1996 1997 BS EN 61169-19:2011 2 61169-19 IEC:2011 CONTENTS 1 Scope . 6 2 Normative references .
18、 6 3 Mating face and gauge information . 6 3.1 Dimensions General purpose connectors Grade 2 . 6 3.1.1 Connector with socket-centre contact 6 3.1.2 Connector with pin-centre contact 8 3.2 Gauges . 9 3.2.1 Gauge pins for socket-centre contact . 9 3.2.2 Test procedure 9 3.2.3 Gauge for outer contact o
19、f socket-centre contact . 10 3.2.4 Test procedure 10 3.3 Dimensions Standard test connectors Grade 0 11 3.3.1 Connector with socket-centre contact 11 3.3.2 Connector with pin-centre contact 12 4 Quality assessment procedure 13 4.1 General . 13 4.2 Rating and characteristics (see Clause 6 of IEC 6116
20、9-1) . 13 4.3 Test schedule and inspection requirements Acceptance tests . 15 4.3.1 Acceptance tests . 15 4.3.2 Periodic tests 16 4.4 Procedures 18 4.4.1 Quality conformance inspection . 18 4.4.2 Qualification approval and its maintenance 18 5 Instructions for preparation of detail specifications .
21、18 5.1 General . 18 5.2 Identification of the component 18 5.3 Performance 19 5.4 Marking, ordering information and related matters . 19 5.5 Selection of tests, test conditions and severities 19 5.6 Blank detail specification pro-forma for type SSMB connector . 20 Figure 1 Connector with socket-cent
22、re contact (for dimensions and notes, see Table 1) . 7 Figure 2 Connector with pin-centre contact (for dimensions and notes, see Table 2) . 8 Figure 3 Gauge pins for socket-centre contact (for dimensions and notes, see Table 3) 9 Figure 4 Outer contact sizing and retention force gauges A and B (for
23、dimensions and notes, see Table 4) 10 Figure 5 Connector with socket-centre contact (for dimensions and notes, see Table 5) . 11 Figure 6 Connector with pin-centre contact (for dimensions and notes, see Table 6) . 12 Table 1 Dimensions of connector with socket-centre contact 7 Table 2 Dimensions of
24、connector with pin-centre contact . 8 Table 3 Dimensions of gauge pins for socket-centre contact 9 Table 4 Dimensions of gauge for outer contact 10 Table 5 Dimensions of connector with socket-centre contact 11 BS EN 61169-19:201161169-19 IEC:2011 3 Table 6 Dimensions of connector with pin-centre con
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN61169192011RADIOFREQUENCYCONNECTORSSECTIONALSPECIFICATIONRADIOFREQUENCYCOAXIALCONNECTORSOFTYPESSMB