BS EN 61094-3-2016 Electroacoustics Measurement microphones Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique《电声学 测量传声器 用互易技.pdf
《BS EN 61094-3-2016 Electroacoustics Measurement microphones Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique《电声学 测量传声器 用互易技.pdf》由会员分享,可在线阅读,更多相关《BS EN 61094-3-2016 Electroacoustics Measurement microphones Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique《电声学 测量传声器 用互易技.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、Electroacoustics Measurement microphonesPart 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity techniqueBS EN 61094-3:2016Incorporating corrigendum December 2016(IEC 61094-3:2016)BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2
2、013 15:06National forewordThis British Standard is the UK implementation of EN 61094-3:2016. It isidentical to IEC 61094-3:2016, incorporating corrigendum December 2016.The UK participation in its preparation was entrusted to TechnicalCommittee EPL/29, Electroacoustics.A list of organizations repres
3、ented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 9
4、7575 2ICS 17.140.50; 33.160.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2016.Amendments/corrigenda issued since publicationDate Text affectedBRI
5、TISH STANDARDBS EN 61094-3:2016Implementation of IEC corrigendum December 2016: 28 February 2017subclause 5.7.2 correctedIt supersedes BS EN 61094-3:1996 which is withdrawn.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61094-3 September 2016 ICS 17.140.50; 33.160.50 Supersedes EN 61094-3:1995
6、 English Version Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique (IEC 61094-3:2016) lectroacoustique - Microphones de mesure - Partie 3: Mthode primaire pour ltalonnage en champ libre des m
7、icrophones talons de laboratoire par la mthode de rciprocit (IEC 61094-3:2016) Messmikrofone - Teil 3: Primrverfahren zur Freifeld-Kalibrierung von Laboratoriums-Normalmikrofonen nach der Reziprozittsmethode (IEC 61094-3:2016) This European Standard was approved by CENELEC on 2016-07-19. CENELEC mem
8、bers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applicat
9、ion to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELE
10、C Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Icela
11、nd, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europis
12、ches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61094-3:2016 E BS EN 61094-3:2016EN 61094-3:2016 2 European foreword The
13、 text of document 29/873/CDV, future edition 2 of IEC 61094-3, prepared by IEC TC 29, Electroacoustics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61094-3:2016. The following dates are fixed: latest date by which the document hasto be implemented at national lev
14、el bypublication of an identical nationalstandard or by endorsement(dop) 2017-04-19 latest date by which the nationalstandards conflicting with thedocument have to be withdrawn(dow) 2019-07-19 This document supersedes EN 61094-3:1995. Attention is drawn to the possibility that some of the elements o
15、f this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61094-3:2016 was approved by CENELEC as a European Standard without any modification. In
16、the official version, for Bibliography, the following note has to be added for the standard indicated: IEC 61094-8:2012 NOTE Harmonized as EN 61094-8:2012. BS EN 61094-3:2016EN 61094-3:2016 3 Annex ZA (normative) Normative references to international publications with their corresponding European pu
17、blications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) appli
18、es. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD
19、Year IEC 61094-1 2000 Measurement microphones - Part 1: Specifications for laboratory standard microphones EN 61094-1 2000 IEC 61094-2 2009 Electroacoustics - Measurement microphones - Part 2: Primary method for the pressure calibration of laboratory standard microphones by the reciprocity technique
20、 EN 61094-2 2009 ISO 9613-1 - Acoustics; attenuation of sound during propagation outdoors; part_1: calculation of the absorption of sound by the atmosphere - - IEC/TS 61094-7 - Measurement microphones - Part 7: Values for the difference between free-field and pressure sensitivity levels of laborator
21、y standard microphones - - ISO/IEC Guide 98-3 - Uncertainty of measurement - Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) - - BS EN 61094-3:2016This page deliberately left blankBS EN 61094-3:2016 2 IEC 61094-3:2016 IEC 2016 CONTENTS FOREWORD . 4 1 Scope 6 2 Normative refe
22、rences. 6 3 Terms and definitions 6 4 Reference environmental conditions . 7 5 Principles of free-field calibration by reciprocity 7 5.1 General principles . 7 5.1.1 General . 7 5.1.2 General principles using three microphones 7 5.1.3 General principles using two microphones and an auxiliary sound s
23、ource . 8 5.2 Basic expressions . 8 5.3 Insert voltage technique 9 5.4 Free-field receiving characteristics of a microphone . 9 5.5 Free-field transmitting characteristics of a microphone . 10 5.6 Reciprocity procedure . 11 5.7 Final expressions for the free-field sensitivity . 11 5.7.1 Method using
24、 three microphones 11 5.7.2 Method using two microphones and an auxiliary sound source 12 6 Factors influencing the free-field sensitivity 12 6.1 General . 12 6.2 Polarizing voltage 12 6.3 Shield configuration 12 6.4 Acoustic conditions . 13 6.5 Position of the acoustic centre of a microphone . 13 6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6109432016ELECTROACOUSTICSMEASUREMENTMICROPHONESPRIMARYMETHODFORFREEFIELDCALIBRATIONOFLABORATORYSTANDARDMICROPHONESBYTHERECIPROCITYTECHNIQUE

链接地址:http://www.mydoc123.com/p-576844.html