BS EN 61000-4-29-2001 Electromagnetic compatibility (EMC) Testing and measurement techniques Testing and measurement techniques Voltage dips short interruptions and voltage variatig.pdf
《BS EN 61000-4-29-2001 Electromagnetic compatibility (EMC) Testing and measurement techniques Testing and measurement techniques Voltage dips short interruptions and voltage variatig.pdf》由会员分享,可在线阅读,更多相关《BS EN 61000-4-29-2001 Electromagnetic compatibility (EMC) Testing and measurement techniques Testing and measurement techniques Voltage dips short interruptions and voltage variatig.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 61000-4-29: 2001 IEC 61000-4-29: 2000 Electromagnetic compatibility (EMC) Part 4-29: Testing and measurement techniques Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests The European Standard EN 61000-4-29:2000 has the status of a
2、 British Standard ICS 33.100.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN 61000-4-29:2001 This British Standard, having been prepared under the direction of the Electrotechnical Sector Committee, was published under the authority of the Standards Committee and comes
3、 into effect on 15 July 2001 BSI 07-2001 ISBN 0 580 37205 7 National foreword This British Standard is the official English language version of EN 61000-4-29:2000. It is identical with IEC 61000-4-29:2000. The UK participation in its preparation was entrusted by Technical Committee GEL/210, EMC-Poli
4、cy, to Subcommittee GEL 1210/8, Low frequency disturbances, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IE
5、C 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references Attention is drawn to the fact that CEN and CENELEC Standards normally include an annex which lists
6、normative references to international publications with their corresponding European publications. The British Standards which implement these international or European publications may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”,
7、 or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confe
8、r immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgat
9、e them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 19, and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date Commen
10、ts(8523($167$1$5 (1 1250(8523e(11( (8523b,6 the test generator; the test set-up; the test procedure. The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the EUT (equipment under test) rated power is greater than
11、 the test generator capacity specified in clause 6. The ripple at the d.c. input power port is not included in the scope of this part of IEC 61000. It is covered by IEC 61000-4-17 1) This standard does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a
12、general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment. 1) IEC 61000-4-17, Electromagnetic compatibility (EMC) Part 4-17:
13、Testing and measurement techniques Ripple on d.c. input power port immunity test Page5 EN61000429:2000 BSI 07-2001 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of IEC 61000. For dated references,
14、 subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part of IEC 61000 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, th
15、e latest edition of the normative document referred to applies. Members of ISO and IEC maintain registers of currently valid International Standards. IEC 60050(161), International Electrotechnical Vocabulary (IEV) Chapter 161: Electro- magnetic compatibility IEC 61000-4-11, Electromagnetic compatibi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN610004292001ELECTROMAGNETICCOMPATIBILITYEMCTESTINGANDMEASUREMENTTECHNIQUESTESTINGANDMEASUREMENTTECHNIQUESVOLTAGEDIPSSHORTINTERRUPTIONSANDVOLTAGEVARIATIGPDF

链接地址:http://www.mydoc123.com/p-576671.html