BS EN 60512-25-2-2002 Connectors for electronic equipment - Tests and measurements - Test 25b - Attenuation (insertion loss) - Section 2 Attenuation (insertion loss)《电子设备连接器 试验和测量 .pdf
《BS EN 60512-25-2-2002 Connectors for electronic equipment - Tests and measurements - Test 25b - Attenuation (insertion loss) - Section 2 Attenuation (insertion loss)《电子设备连接器 试验和测量 .pdf》由会员分享,可在线阅读,更多相关《BS EN 60512-25-2-2002 Connectors for electronic equipment - Tests and measurements - Test 25b - Attenuation (insertion loss) - Section 2 Attenuation (insertion loss)《电子设备连接器 试验和测量 .pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 60512-25-2: 2002 Connectors for electronic equipment Tests and measurements Part 25-2: Test 25b: Attenuation (insertion loss) The European Standard EN 60512-25-2:2002 has the status of a British Standard ICS 31.220.10 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY CO
2、PYRIGHT LAWBS EN 60512-25-2:2002 This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 9 July 2002 BSI 9 July 2002 ISBN 0 580 39945 1 National f
3、oreword This British Standard is the official English language version of EN 60512-25-2:2002. It is identical with IEC 60512-25-2:2002. The UK participation in its preparation was entrusted by Technical Committee EPL/48, Electromechanical components and mechanical structures for electronic equipment
4、, to Subcommittee EPL/48/2, Connectors for electronic equipment, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instanc
5、e, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which implement international or European publications referred to in thi
6、s document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a con
7、tract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, an
8、d keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 14, an inside back cover and a back cover. The BSI copyright date disp
9、layed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 60512-25-2 NORME EUROPENNE EUROPISCHE NORM June 2002 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Elect
10、rotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-25-2:2002 E ICS 31.220.10 English version Connector
11、s for electronic equipment - Tests and measurements Part 25-2: Test 25b: Attenuation (insertion loss) (IEC 60512-25-2:2002) Connecteurs pour quipements lectroniques - Essais et mesures Partie 25-2: Essai 25b: Attnuation (perte dinsertion) (CEI 60512-25-2:2002) Steckverbinder fr elektronische Einrich
12、tungen - Mess- und Prfverfahren Teil 25-2: Prfung 25b: Dmpfung (Einfgedmpfung) (IEC 60512-25-2:2002) This European Standard was approved by CENELEC on 2002-05-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Sta
13、ndard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, Fr
14、ench, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium
15、, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.Foreword The text of document 48B/1154/FDIS, future edition 1 of IEC 60512-25-2, prepared by SC 48B, Connectors, of IE
16、C TC 48, Electromechanical components and mechanical structures for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60512-25-2 on 2002-05-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by
17、publication of an identical national standard or by endorsement (dop) 2003-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2005-05-01 Annexes designated “normative“ are part of the body of the standard. Annexes designated “informative“ are given f
18、or information only. In this standard, annex A is normative and annex B is informative. _ Endorsement notice The text of the International Standard IEC 60512-25-2:2002 was approved by CENELEC as a European Standard without any modification. _ Page2 EN60512252:2002 BSI9July2002065-2125-2 CEI:0220 3 C
19、ONTENTS 1 General 4 1.1 Scope4 1.2 Definitions.7 2 Test resources .4 2.1 Equipment.4 2.2 Fixture.5 3 Test specimen6 3.1 Description6 4 Test procedure .6 4.1 Fixture attenuation 6 4.2 Specimen attenuation measurement7 4.3 Impedance analyzer (open/short method)8 4.4 Additional measurements 8 4.5 Time
20、domain method.8 5 Details to be specified 9 6 Test documentation9 Annex A (normative) Diagrams and schematics of fixtures and equipment10 Annex B (informative) Practical guidance14 Figure A.1 Technical diagrams.10 Figure A.2 Single-ended terminations 11 Figure A.3 Differential (balanced) termination
21、s 12 Figure A.4 Example of specimen in fixture for attenuation13 Page3 EN60512252:2002 BSI9July2002065-2125-2 CEI:0220 4 CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUREMENTS Part 25-2: Test 25b Attenuation (insertion loss) 1 General 1.1 Scope and object This part of IEC 60512 is applicable to
22、electrical connectors, sockets, cable assemblies or interconnection systems. This standard describes a frequency and a time domain method to measure attenuation/ insertion loss as a function of frequency. NOTE “Attenuation” is referenced throughout the document. Test professionals must use the appro
23、priate term (attenuation or insertion loss) when summarizing and reporting the test measurements according to the type of specimen and transmission line being measured. 1.2 Definitions For the purpose of this part of IEC 60512, the following definitions apply. 1.2.1 attenuation the reduction of powe
24、r during the transmission from the input to the output of the specimen, usually measured in decibels (dB) 1.2.2 insertion loss the loss of power resulting from the insertion of a connector or similar device into a transmission line, usually measured in dB 1.2.3 specimen environment impedance the imp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN605122522002CONNECTORSFORELECTRONICEQUIPMENTTESTSANDMEASUREMENTSTEST25BATTENUATIONINSERTIONLOSSSECTION2ATTENUATIONINSERTIONLOSS

链接地址:http://www.mydoc123.com/p-575836.html