BS EN 60079-15-2010 Explosive atmospheres nPart 15 Equipment protection by type of nprotection n 《爆炸性气体环境 n 型保护电器装置》.pdf
《BS EN 60079-15-2010 Explosive atmospheres nPart 15 Equipment protection by type of nprotection n 《爆炸性气体环境 n 型保护电器装置》.pdf》由会员分享,可在线阅读,更多相关《BS EN 60079-15-2010 Explosive atmospheres nPart 15 Equipment protection by type of nprotection n 《爆炸性气体环境 n 型保护电器装置》.pdf(84页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 60079-15:2010Explosive atmospheresPart 15: Equipment protection by type of protection “n“(IEC 60079-15:2010)BS EN 60079-15:2010Incorporating corrigendum November 2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 60079-15:2010 BRITISH STANDARDNational fo
2、rewordThis British Standard is the UK implementation of EN 60079-15:2010. It is identical to IEC 60079-15:2010. It supersedes BS EN 60079-15:2005 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EXL/31, Equipment for explosive atmospheres.A list of orga
3、nizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016. Published by BSI Standards Limited 2
4、016ISBN 978 0 580 96227 1ICS 29.260.20Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2010.Amendments/corrigenda issued since publicationDate Text a
5、ffected30 November 2016 Implementation of IEC Interpretation Sheet 1 September 2016 in National Annex NAIEC 60079-15:2010/ISH1:2016 IEC 2016 1 ICS 29.260.20 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ IEC 60079-15 Edition 4.0 2010-01 EXPLOSIVE ATMOSPHERES Part 15: Equipment protection by type of pro
6、tection “n“ INTERPRETATION SHEET 1This interpretation sheet has been prepared by IEC technical committee 31: Equipment for explosive atmospheres. The text of this interpretation sheet is based on the following documents: ISH Report on voting 31/1259/ISH 31/1273/RVD Full information on the voting for
7、 the approval of this interpretation sheet can be found in the report on voting indicated in the above table. _ IEC 60079-15:2010 Edition 4.0, Explosive atmospheres Part 15: Equipment protection by type of protection “n“ Question: Do the requirements given in 8.3 prohibit the use of a terminal box o
8、pened to the interior of a motor rated 1 kV or greater, provided the interior of the machine has an ingress protection of IP54 or greater? IEC 60079-15:2010 Edition 4.0 8.3 Terminal boxes Terminal boxes attached to machines operating at voltages up to 1 kV, may be opened to the interior of the machi
9、ne, only when the IP rating of the machine is IP44 or higher. The external IP protection of the box shall be not less than IP54, as determined in accordance with IEC 60079-0. IEC 60079-15:2010-01/ISH1:2016-09(en-fr)BS EN 60079-15:2010 National Annex NA (informative) 2 IEC 60079-15:2010/ISH1:2016 IEC
10、 2016 Answer: No. As long as the interior of the machine has an ingress protection of IP54 or greater, determined in accordance with IEC 60079-0, there is no limitation to less than 1 kV. If the interior of the machine has an ingress rating of IP44 or lower, the use of a terminal box open to the int
11、erior of a motor rated 1 kV or greater is not permitted. NOTE Many manufacturers opt to declare IP44 for the machine for certification purposes, whilst claiming a rating of IP54 or higher, by assessment, for contractual purposes in order to avoid the difficult testing required for certification of t
12、he IP of larger machines. As such, this additional IP rating need only comply with IEC 60529 or IEC 60034-5 as applicable, and not with any of the testing detailed in IEC 60079-0. BS EN 60079-15:2010 EUROPEAN STANDARD EN 60079-15NORME EUROPENNE EUROPISCHE NORM May 2010 CENELEC European Committee for
13、 Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref
14、. No. EN 60079-15:2010 E ICS 29.260.20 Supersedes EN 60079-15:2005English version Explosive atmospheres - Part 15: Equipment protection by type of protection “n“ (IEC 60079-15:2010) Atmosphres explosives - Partie 15: Protection du matriel par mode de protection “n“ (CEI 60079-15:2010) Explosionsfhig
15、e Atmosphre - Teil 15: Gerteschutz durch Zndschutzart “n“ (IEC 60079-15:2010) This European Standard was approved by CENELEC on 2010-05-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a n
16、ational standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A versio
17、n in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cy
18、prus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. 2 IEC 60079-15:2010/ISH1:20
19、16 IEC 2016 Answer:No. As long as the interior of the machine has an ingress protection of IP54 or greater,determined in accordance with IEC 60079-0, there is no limitation to less than 1 kV. If the interior of the machine has an ingress rating of IP44 or lower, the use of a terminal box open to the
20、 interior of a motor rated 1 kV or greater is not permitted.NOTE Many manufacturers opt to declare IP44 for the machine for certification purposes, whilst claiming a rating of IP54 or higher, by assessment, for contractual purposes in order to avoid the difficult testing required forcertification of
21、 the IP of larger machines. As such, this additional IP rating need only comply with IEC 60529 orIEC 60034-5 as applicable, and not with any of the testing detailed in IEC 60079-0. EN 60079-15:2010 - 2 - Foreword The text of document 31/833/FDIS, future edition 4 of IEC 60079-15, prepared by IEC TC
22、31, Equipment for explosive atmospheres, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60079-15 on 2010-05-01. This European Standard supersedes EN 60079-15:2005. The significant technical changes with respect to EN 60079-15:2005 are as follows: addition of equipme
23、nt protection levels; removal of the requirements for energy-limited “nL” and associated energy limited apparatus “nL”; removal of the requirements for encapsulated Devices “nC”; requirements for electrical connections expanded and clarified; requirements for luminaire ballasts expanded and clarifie
24、d; requirements for evaluation and testing of motor rotors clarified; 15 kV limit for equipment protection by type of protection “n“ added; spacing requirement for voltages above 10 kV modified; requirements for restricted breathing enclosures modified; modification to requirements for motor rotors
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN60079152010EXPLOSIVEATMOSPHERESNPART15EQUIPMENTPROTECTIONBYTYPEOFNPROTECTIONN 爆炸性 气体 环境 保护 电器 装置

链接地址:http://www.mydoc123.com/p-575259.html