BS EN 60076-5-2006 Power transformers - Ability to withstand short-circuit《电力变压器 耐短路性能》.pdf
《BS EN 60076-5-2006 Power transformers - Ability to withstand short-circuit《电力变压器 耐短路性能》.pdf》由会员分享,可在线阅读,更多相关《BS EN 60076-5-2006 Power transformers - Ability to withstand short-circuit《电力变压器 耐短路性能》.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58The European Standard EN 60076-5:2006 has the status of a British StandardICS 29.180Power transform
2、ers Part 5: Ability to withstand short-circuit BRITISH STANDARDBS EN 60076-5:2006BS EN 60076-5:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2006 BSI 2006ISBN 0 580 48784 9request to its secretary.Cross-referencesThe British Sta
3、ndards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.Thi
4、s publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front
5、 cover, the EN title page, pages 2 to 36, an inside back cover and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsA list of organizations represented on this committee can be obtain
6、ed on present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.National forewordThis British Standard is the official
7、 English language version of EN 60076-5:2006. It is identical with IEC 60076-5:2006. It supersedes BS EN 60076-5:2001 which will be withdrawn on 1 April 2009.The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers, which has the responsibility to: aid
8、enquirers to understand the text;EUROPEAN STANDARD EN 60076-5 NORME EUROPENNE EUROPISCHE NORM June 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassar
9、t 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60076-5:2006 E ICS 29.180 Supersedes EN 60076-5:2000English version Power transformers Part 5: Ability to withstand short-circuit (IEC 60076-5:2006) Tran
10、sformateurs de puissance Partie 5: Tenue au court-circuit (CEI 60076-5:2006) Leistungstransformatoren Teil 5: Kurzschlussfestigkeit (IEC 60076-5:2006) This European Standard was approved by CENELEC on 2006-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which sti
11、pulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Stand
12、ard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the nation
13、al electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerla
14、nd and the United Kingdom. Foreword The text of document 14/518/FDIS, future edition 3 of IEC 60076-5, prepared by IEC TC 14, Power transformers, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60076-5 on 2006-04-01. This European Standard supersedes EN 60076-5:2000.
15、 This European Standard includes the following significant technical changes with respect to EN 60076-5:2000: a) introduction of Annex A (informative) “Theoretical evaluation of the ability to withstand the dynamic effects of short circuit“, in place of previous Annex B (normative) “Calculation meth
16、od for the demonstration of the ability to withstand short circuit“ (blank); b) introduction of Annex B (informative) “Definition of similar transformer“, in place of previous Annex A (informative) “Guidance for the identification of a similar transformer“. The following dates were fixed: latest dat
17、e by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-01-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-04-01 Annex ZA has been added by CENELEC. _ Endorsement no
18、tice The text of the International Standard IEC 60076-5:2006 was approved by CENELEC as a European Standard without any modification. _ EN 60076-5:2006 2 3 EN 60076-5:2006 CONTENTS 1 Scope 4 2 Normative references .4 3 Requirements with regard to ability to withstand short circuit .4 3.1 General .4
19、3.2 Overcurrent conditions.5 4 Demonstration of ability to withstand short circuit 8 4.1 Thermal ability to withstand short circuit.8 4.2 Ability to withstand the dynamic effects of short circuit .11 Annex A (informative) Theoretical evaluation of the ability to withstand the dynamic effects of shor
20、t circuit .20 Annex B (informative) Definition of similar transformer35 Annex ZA (normative) Normative references to international publications with their corresponding European publications36 Figure 1 Star/delta connected transformer 14 Figure 2 Star/star auto-transformer.15 Table 1 Recognized mini
21、mum values of short-circuit impedance for transformers with two separate windings .6 Table 2 Short-circuit apparent power of the system.6 Table 3 Maximum permissible values of the average temperature of each winding after short circuit.10 Table 4 Values for factor k 2 12 Table A.1 Comparison of forc
22、es and stresses in core-type transformers30 Table A.2 Comparison of forces and stresses in shell-type transformers .32 Table A.3 Values for factor K3.34 Table A.4 Values for factor K4.34 EN 60076-5:2006 4 POWER TRANSFORMERS Part 5: Ability to withstand short circuit 1 Scope This part of IEC 60076 id
23、entifies the requirements for power transformers to sustain without damage the effects of overcurrents originated by external short circuits. It describes the calculation procedures used to demonstrate the thermal ability of a power transformer to withstand such overcurrents and both the special tes
24、t and the theoretical evaluation method used to demonstrate the ability to withstand the relevant dynamic effects. The requirements apply to transformers as defined in the scope of IEC 60076-1. 2 Normative references The following referenced documents are indispensable for the application of this do
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6007652006POWERTRANSFORMERSABILITYTOWITHSTANDSHORTCIRCUIT 电力变压器 短路 性能 PDF

链接地址:http://www.mydoc123.com/p-575249.html