BS EN 60076-3-2013 Power transformers Insulation levels dielectric tests and external clearances in air《电力变压器 绝缘水平、电介质试验和空气中的外间隙》.pdf
《BS EN 60076-3-2013 Power transformers Insulation levels dielectric tests and external clearances in air《电力变压器 绝缘水平、电介质试验和空气中的外间隙》.pdf》由会员分享,可在线阅读,更多相关《BS EN 60076-3-2013 Power transformers Insulation levels dielectric tests and external clearances in air《电力变压器 绝缘水平、电介质试验和空气中的外间隙》.pdf(60页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationPower transformersPart 3: Insulation levels, dielectric tests and external clearances in airBS EN 60076-3:2013National forewordThis British Standard is the UK implementation of EN 60076-3:2013. It isidentical to IEC 60076-3:2013. It supersedes BS EN 60076-3:2001, which willb
2、e withdrawn on 4 September 2016.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/14, Power transformers.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provi
3、sions ofa contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN 978 0 580 72472 5ICS 29.180Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published und
4、er the authority of theStandards Policy and Strategy Committee on 31 December 2013.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60076-3:2013EUROPEAN STANDARD EN 60076-3 NORME EUROPENNE EUROPISCHE NORM November 2013 CENELEC European Committee for Electrotechni
5、cal Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref.
6、No. EN 60076-3:2013 E ICS 29.180 Supersedes EN 60076-3:2001 English version Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air (IEC 60076-3:2013) Transformateurs de puissance - Partie 3: Niveaux disolement, essais dilectriques et distances disolement dans
7、 lair (CEI 60076-3:2013) Leistungstransformatoren - Teil 3: Isolationspegel, Spannungsprfungen und uere Abstnde in Luft (IEC 60076-3:2013) This European Standard was approved by CENELEC on 2013-09-04. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the c
8、onditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standar
9、d exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are th
10、e national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Polan
11、d, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 60076-3:2013EN 60076-3:2013 - 2 - Foreword The text of document 14/745/FDIS, future edition 3 of IEC 60076-3, prepared by IEC/TC 14 “Power transformers“ was submitted to the IEC-CENELEC paralle
12、l vote and approved by CENELEC as EN 60076-3:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-06-04 latest date by which the national standards conflicting with
13、 the document have to be withdrawn (dow) 2016-09-04 This document supersedes EN 60076-3:2001. EN 60076-3:2013 includes the following significant technical changes with respect to EN 60073-3:2001: Three categories of transformer are clearly identified together with the relevant test requirements, the
14、se are summarised in Table 1. Switching impulse levels are defined for all Um72,5kV. The procedure for Induced voltage tests with PD has been revised to ensure adequate phase to phase test voltages. The AC withstand test has been redefined (LTAC instead of ACSD). Induced voltage tests are now based
15、on Ur rather than Um. New requirements for impulse waveshape (k factor) have been introduced. Tables of test levels have been merged and aligned with IEC 60071-1:2010. Additional test levels have been introduced for Um 800kV. A new Annex E has been introduced, which sets out the principles used in a
16、ssigning the tests, test levels and clearances in air. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of
17、the International Standard IEC 60076-3:2013 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60071-2 NOTE Harmonized as EN 60071-2. IEC 60076-4 NOTE Harmonized as
18、EN 60076-4. IEC 60214-1 NOTE Harmonized as EN 60214-1. IEC 61083-1 NOTE Harmonized as EN 61083-1. IEC 61083-2 NOTE Harmonized as EN 61083-2. IEC 62271-1 NOTE Harmonized as EN 62271-1. BS EN 60076-3:2013- 3 - EN 60076-3:2013 Annex ZA (normative) Normative references to international publications with
19、 their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document
20、(including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60050-421 International electrotechnical vocabulary (IEV) - Chapter 421: Power transformers and
21、reactors - - IEC 60060-1 High-voltage test techniques Part 1: General definitions and test requirements EN 60060-1 IEC 60060-2 High-voltage test techniques - Part 2: Measuring systems EN 60060-2 IEC 60071-1 Insulation co-ordination - Part 1: Definitions, principles and rules EN 60071-1 IEC 60076-1 P
22、ower transformers - Part 1: General EN 60076-1 IEC 60137 Insulated bushings for alternating voltages above 1 000 V EN 60137 IEC 60270 High-voltage test techniques - Partial discharge measurements EN 60270 BS EN 60076-3:2013 2 60076-3 IEC:2013 CONTENTS INTRODUCTION . 6 1 Scope . 7 2 Normative referen
23、ces 7 3 Terms and definitions . 7 4 General 8 5 Highest voltage for equipment and rated insulation level 10 6 Transformers with re-connectable windings . 11 7 Dielectric tests 12 7.1 Overview . 12 7.2 Test requirements 13 7.2.1 General . 13 7.2.2 Test voltage levels . 14 7.2.3 Test sequence . 17 7.3
24、 Test requirements for specific transformers . 17 7.3.1 Tests for transformers with Um 72,5 kV . 17 7.3.2 Tests on transformers with 72,5 kV 170 kV . 19 7.4 Assigning Umand test voltages to the neutral terminal of a winding . 20 7.4.1 Transformers with Um 72,5 kV 20 7.4.2 Transformers with Um 72,5 k
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6007632013POWERTRANSFORMERSINSULATIONLEVELSDIELECTRICTESTSANDEXTERNALCLEARANCESINAIR 电力变压器 绝缘 水平

链接地址:http://www.mydoc123.com/p-575247.html