《BS EN 50526-2-2014 Railway applications Fixed installations D C surge arresters and voltage limiting devices Voltage limiting devices《轨道交通 固定设施 直流电涌放电器和电压限制器 电压限制器》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50526-2-2014 Railway applications Fixed installations D C surge arresters and voltage limiting devices Voltage limiting devices《轨道交通 固定设施 直流电涌放电器和电压限制器 电压限制器》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 50526-2:2014Railway applications Fixedinstallations D.C. surgearresters and voltage limitingdevices -Part 2: Voltage limiting devicesBS EN 50526-2:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50526-2:2014.The UK participati
2、on in its preparation was entrusted to TechnicalCommittee GEL/9/3, Railway Electrotechnical Applications - FixedEquipment.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a con
3、tract. Users are responsible for its correctapplication. The British Standards Institution 2014. Published by BSI StandardsLimited 2014ISBN 978 0 580 73005 4ICS 29.120.50; 29.280Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under
4、the authority of theStandards Policy and Strategy Committee on 31 March 2014.Amendments issued since publicationDate Text affectedBS EN 50526-2:2014EUROPEAN STANDARD EN 50526-2 NORME EUROPENNE EUROPISCHE NORM February 2014 CENELEC European Committee for Electrotechnical Standardization Comit Europen
5、 de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50526-2:2014 E ICS 29.120.
6、50; 29.280 English version Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 2: Voltage limiting devices Applications ferroviaires - Installations fixes - Parafoudres et limiteurs de tension pour systmes courant continu - Partie 2: Limiteurs de ten
7、sion Bahnanwendungen - Ortsfeste Anlagen - berspannungsableiter und Spannungsbegrenzungseinrichtungen - Teil 2: Spannungsbegrenzungseinrichtungen This European Standard was approved by CENELEC on 2013-12-30. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulat
8、e the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European
9、Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members
10、 are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway
11、, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 50526-2:2014EN 50526-2:2014 - 2 - Contents Page Foreword . 4 1 Scope 5 2 Normative references 5 3 Terms and definitions . 6 4 Classes of VLD . 8 5 Characteristics and requirements of the
12、 VLDs 9 5.1 Marking . 9 5.2 Service requirements 9 5.2.1 Normal outdoor service conditions . 9 5.2.2 Normal indoor service conditions . 9 5.2.3 Abnormal service conditions . 10 5.3 General characteristics . 10 5.4 Minimum requirements . 10 5.4.1 Response time . 10 5.4.2 Additional requirements for V
13、LDs of class 1 10 5.4.3 Additional requirements for VLDs of classes 3 and 4 . 10 5.5 Electrical characteristics and thermal rating 11 5.6 Protection of VLDs against lightning 11 5.7 Command and control (class 3 and 4 only) 12 5.7.1 Local control 12 5.7.2 Remote signalling 12 5.7.3 Operation and alar
14、m recordings 12 6 Type tests . 13 6.1 General . 13 6.2 Nominal triggering voltage UTnand non-triggering voltage UW14 6.2.1 Procedure for welding shutspark gap VLDs (Class 1) . 14 6.2.2 Procedure for thyristor type VLDs (Class2) 14 6.2.3 Procedure for mechanical switching VLDs and for combined thyris
15、tors with mechanical switching devices VLDs (Class 3 and Class 4) 15 6.3 Leakage current . 15 6.4 D.C. current withstand 15 6.4.1 General . 15 6.4.2 Procedure to determine the rated current. 15 6.4.3 Procedure to determine short time withstand current 16 6.5 A.C. current withstand characteristics (o
16、ptional) 17 6.6 Response time characteristics . 18 6.6.1 Response time for d.c. voltage 18 6.6.2 Response time for combined a.c.-d.c. voltage . 20 BS EN 50526-2:2014- 3 - EN 50526-2:2014 6.7 Lightning current withstand characteristics for VLDs exposed to direct lightning strikes 21 6.8 Recovery test
17、 (Class 3, 4) . 23 6.9 Reverse voltage test (Class 2.1) . 23 6.10 Dielectric tests for panel type voltage limiting devices (Class 3 and 4) 24 6.10.1 Test conditions 24 6.10.2 Power-frequency voltage withstand test. 24 6.11 Degree of protection 24 6.12 Environmental tests for outdoor equipment 25 6.1
18、3 Determination of minimum current for safe short circuiting of Class 1 VLDs 25 7 Routine tests 26 7.1 General . 26 7.2 VLDs of classes 3 and 4 26 7.3 Dielectric tests for panel type voltage limiting devices. 26 Annex A (informative) Preferred ranges of the principal properties of the VLDs 27 Biblio
19、graphy 31 Figures Figure 1 Test circuit for testing of response time 19 Figure 2 TR evaluation. 19 Figure 3 Response time characteristic 20 Figure 4 Test circuit for testing of response time TRfor combined a.c.-d.c. voltage 21 Figure 5 Evaluation of response time TRfor combined a.c.-d.c voltage 21 F
20、igure 6 Circuit for the Recovery Voltage test 23 Tables Table 1 Classes of voltage-limiting device . 8 Table 2 Type tests . 13 Table 3 Maximum response time as a function of d.c. voltages 18 Table 4 Maximum response time for combined a.c.-d.c. voltages 20 Table A.1 Nominal Triggering voltage UTn27 T
21、able A.2 Instantaneous Triggering Voltage UTI27 Table A.3 Rated current Ir. 28 Table A.4 Short time withstand current IW28 Table A.5 Leakage current IL28 Table A.6 Making and breaking capacity 28 Table A.7 Nominal lightning current (8/20 s) Iimp-n. 29 Table A.8 High current impulse 8/20 s and 4/10 s
22、 Iimp-high. 29 Table A.9 High charge impulse Iimp-hc29 Table A.10 Current-time characteristic for safe short circuiting of Class 1 VLDs . 30 BS EN 50526-2:2014EN 50526-2:2014 - 4 - Foreword This document (EN 50526-2:2014) has been prepared by CLC/SC 9XC “Electric supply and earthing systems for publ
23、ic transport equipment and ancillary apparatus (Fixed installations)“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-12-30 latest date by which the national stand
24、ards conflicting with this document have to be withdrawn (dow) 2016-12-30 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This Europea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5052622014RAILWAYAPPLICATIONSFIXEDINSTALLATIONSDCSURGEARRESTERSANDVOLTAGELIMITINGDEVICESVOLTAGELIMITINGDEVICES

链接地址:http://www.mydoc123.com/p-575020.html