BS EN 50369-2005 Liquid tight sheathing systems for cable management《电缆管理用防水铠装系统》.pdf
《BS EN 50369-2005 Liquid tight sheathing systems for cable management《电缆管理用防水铠装系统》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50369-2005 Liquid tight sheathing systems for cable management《电缆管理用防水铠装系统》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58The European Standard EN 50369:2005 has the status of a British StandardICS 29.120.10Liquid tight s
2、heathing systems for cable managementBRITISH STANDARDBS EN 50369:2005BS EN 50369:2005This British Standard was published under the authority of the Standards Policy and Strategy Committee on 19 October 2005 BSI 19 October 2005ISBN 0 580 46766 XNational forewordThis British Standard is the official E
3、nglish language version of EN 50369:2005.The UK participation in its preparation was entrusted to Technical Committee PEL/213, Cable management, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe Brit
4、ish Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Onl
5、ine.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsibl
6、e international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, the EN
7、title page, pages 2 to 25 and a back cover.The BSI copyright date displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 50369 NORME EUROPENNE EUROPISCHE NORM August 2005 CENELEC European Committee for Elec
8、trotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref.
9、 No. EN 50369:2005 E ICS 29.120.10 English version Liquid tight sheathing systems for cable management Systmes de gaines souples de protection contre les liquides pour la gestion du cblage Flssigkeitsdichte Elektroinstallations-schlauchsysteme This European Standard was approved by CENELEC on 2005-0
10、4-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obt
11、ained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Cen
12、tral Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherl
13、ands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 50369:2005 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 213, Cable management. The text of the draft was submitted to the formal vote and was approved by CENE
14、LEC as EN 50369 on 2005-04-12. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-04-01 latest date by which the national standards conflicting with the EN have to be withdr
15、awn (dow) 2008-04-01 _ 3 EN 50369:2005 Contents Page 1 Scope.4 2 Normative references4 3 Definitions 4 4 General requirements .5 5 General conditions for tests 5 6 Classification 6 7 Marking and documentation 8 8 Dimensions.8 9 Construction .8 10 Mechanical properties.9 11 Electrical properties 11 1
16、2 Thermal properties .12 13 Fire hazard .13 14 External influences .15 15 Electromagnetic compatibility17 Annex A (informative) A-deviations.25 Figure 1 Gauge for checking the minimum inside diameter of the liquid tight sheathing system 18 Figure 2 Impact test apparatus .19 Figure 3 Arrangement for
17、flexing test20 Figure 4 Arrangement for insulation resistance and electric strength test 21 Figure 5 Enclosure for burning test.22 Figure 6 Arrangement for burning test 23 Figure 7 Assembly of liquid tight sheathing and fitting for bonding test 24 Table 1 Lower temperature range.7 Table 2 Upper temp
18、erature range.7 Table 3 Impact test values9 Table 4 Tensile force10 Table 5 Times of exposure of the sample to the flame 14 Table 6 Resistance to corrosion classification.16 EN 50369:2005 4 1 Scope This European Standard specifies the requirements against ingress of water and tests for flexible non-
19、flame propagating liquid tight sheathing systems for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 500 V d.c. This standard applies to metallic, non-metallic and composite liquid tight sheathing
20、 systems including threaded fittings which terminate the system This European Standard does not apply to conduit systems for electrical installations which come within the scope of EN 50086 series as well as EN 61386 series. Liquid tight sheathing systems do not provide mechanical protection to insu
21、lated conductors and/or cables. They are not for use within the construction of buildings as a component of a fixed wiring system. NOTE Earthing conductors may or may not be insulated. 2 Normative references The following referenced documents are indispensable for the application of this document. F
22、or dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 60423 1994 Conduits for electrical purposes Outside diameters of conduits for electrical installations and threads for conduits and fittin
23、gs (IEC 60423:1993, mod.) EN 60529 1991 Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989) EN 60695-2-11 2001 Fire hazard testing Part 2-11: Glowing/hot-wire based test methods Glow-wire flammability test method for end-products (IEC 60695-2-11:2000) EN 60695-11-2 2003 Fire haza
24、rd testing Part 11-2: Test flames - 1 kW nominal pre-mixed flame - Apparatus, confirmatory test arrangement and guidance (IEC 60695-11-2:2003) 3 Definitions For the purposes of this document, the following terms and definitions apply. 3.1 liquid tight sheathing system closed wiring system consisting
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN503692005LIQUIDTIGHTSHEATHINGSYSTEMSFORCABLEMANAGEMENT 电缆 管理 防水 系统 PDF

链接地址:http://www.mydoc123.com/p-574845.html