1、Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/05/2008 04:07, Uncontrolled Copy, (c) BSIg49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58P
2、art 6: Power suppliesICS 13.310Alarm systems Intrusion and hold-up systems BRITISH STANDARDBS EN 50131-6:2008BS EN 50131-6:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/05/2008 04:07, Uncontrolled Copy, (c) BSIThis British Standard was published under the authority of the Standards P
3、olicy and Strategy Committee on 29 February 2008 BSI 2008ISBN 978 0 580 55445 2Amendments/corrigenda issued since publicationDate Commentscontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. National forewordThi
4、s British Standard is the UK implementation of EN 50131-6:2008. It supersedes BS EN 50131-6:1998 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee GW/1, Electronic security systems.A list of organizations represented on this committee can be obtained on
5、request to its secretary.This publication does not purport to include all the necessary provisions of a EUROPEAN STANDARD EN 50131-6 NORME EUROPENNE EUROPISCHE NORM January 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europische
6、s Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50131-6:2008 E ICS 13.310 Supersedes EN 50131-6:1997English version Alarm syste
7、ms - Intrusion and hold-up systems - Part 6: Power supplies Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 6: Alimentation Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 6: Energieversorgungen This European Standard was approved by CENELEC on 2007-12-01. CENELEC
8、 members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on appl
9、ication to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretar
10、iat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Ne
11、therlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/05/2008 04:07, Uncontrolled Copy, (c) BSIEN 50131-6:2008 - 2 - Foreword This European Standard was prepared by the Technical
12、Committee CENELEC TC 79, Alarm systems. The text of the daft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50131-6 on 2007-12-01. This European Standard supersedes EN 50131-6:1997 + corrigendum April 1998. The following dates were fixed: latest date by which the
13、EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-12-01 EN 50131 will consist of the following parts, under the general tit
14、le Alarm systems - Intrusion and hold-up systems: Part 1 System requirements Part 22 Intrusion detectors Passive infrared detectors Part 23 Intrusion detectors Microwave detectors Part 24 Intrusion detectors Combined passive infrared / Microwave detectors Part 25 Intrusion detectors Combined passive
15、 infrared / Ultrasonic detectors Part 26 Intrusion detectors Opening contacts (magnetic) Part 271 Intrusion detectors Glass break detectors Acoustic Part 272 Intrusion detectors Glass break detectors Passive Part 273 Intrusion detectors Glass break detectors Active Part 3 Control and indicating equi
16、pment Part 4 Warning devices Part 53 Requirements for interconnections equipment using radio frequency techniques Part 6 Power supplies Part 7 Application guidelines Part 8 Security fog devices Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/05/2008 04:07, Uncontrolled Copy, (c) BSI- 3 - E
17、N 50131-6:2008 Contents Introduction 5 1 Scope 6 2 Normative references 6 3 Definitions and abbreviations . 7 3.1 Definitions 7 3.2 Abbreviations . 9 4 Functional requirements . 9 4.1 General 9 4.2 Monitoring of PS 11 4.3 APS Capability. 14 4.4 Recharging for PS type A. 14 4.5 Over-voltage Protectio
18、n .15 4.6 Short Circuit Protection 15 4.7 Overload Protection . 15 4.8 Deep Discharge Protection 15 4.9 Automatic changeover to APS . 15 4.10 Ripple 15 4.11 Tamper Security 15 4.12 Environmental 17 4.13 Safety 17 4.14 EMC 18 4.15 Electrical 18 5 Marking. 19 6 Documentation. 19 7 Tests . 20 7.1 Gener
19、al test conditions 21 7.2 Reduced Functional Test . 21 7.3 PS Rating 22 7.4 Output Voltage Stability - Gradual Load Variation 23 7.5 Output Voltage Stability Switched Load Variation 24 7.6 Signalling: Loss of EPS 25 7.7 Signalling: Storage Device Low Voltage 26 7.8 Signalling: Storage Device Failure
20、 27 7.9 Signalling: Low Output Voltage 28 7.10 Signalling: Power Unit Failure 29 7.11 Signalling: Power Unit Failure SD Charging 29 7.12 Remote Test 30 7.13 SD Recharging 31 7.14 Over-voltage Protection .32 7.15 Short Circuit protection. 33 7.16 Overload Protection . 34 7.17 Deep Discharge Protectio
21、n 35 7.18 Automatic Changeover to APS. 36 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 14/05/2008 04:07, Uncontrolled Copy, (c) BSIEN 50131-6:2008 - 4 - 7.19 Tamper Protection . 36 7.20 Tamper Protection Access to the inside of the housing . 4 7.21 Tamper Detection Removal from Mounting .
22、38 7.22 Tamper Detection Penetration of the housing . 39 7.23 Environmental and EMC 39 7.24 Marking and Documentation 40 Annex A (informative) Determination of Storage device failure . 41 Figure 1 Power Supply Types 10 Table 1 Power Supply Functions 11 Table 2 Power Supply Signalling 12 Table 3 Maxi
23、mum Time to Detect and Signal Storage Device Low Voltage. 13 Table 4 Tamper Detection 16 Table 5 Removal from Mounting 16 Table 6 Environmental and EMC Tests and Severity . 17 Table 7 Tests for PS according to type 20 Table A.1 Minimum Load times for Common Storage Devices in Use in I b) brief descr
24、iption of operation including characteristics of monitoring functions provided; c) type of PS (A, B or C); d) for types A and B, voltage rating and frequency requirements of the EPS; e) rated output of the power supply and maximum rated output of each independent power output; f) the power requireme
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5013162008ALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSPOWERSUPPLIES 报警 系统 侵入 拦截 电源 PDF

链接地址:http://www.mydoc123.com/p-574591.html