BS EN 50131-5-3-2017 Alarm systems Intrusion systems Requirements for interconnections equipment using radio frequency techniques《警报系统 侵入探测系统 使用射频技术的互联设备要求》.pdf
《BS EN 50131-5-3-2017 Alarm systems Intrusion systems Requirements for interconnections equipment using radio frequency techniques《警报系统 侵入探测系统 使用射频技术的互联设备要求》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50131-5-3-2017 Alarm systems Intrusion systems Requirements for interconnections equipment using radio frequency techniques《警报系统 侵入探测系统 使用射频技术的互联设备要求》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 50131-5-3:2017Alarm systems IntrusionsystemsPart 5-3: Requirements for interconnectionsequipment using radio frequencytechniquesBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 50131-5-3:2017 BRITISH STANDARDNational forewordThis British Standard is the UK
2、 implementation of EN 50131-5-3:2017. It supersedes BS EN 50131-5-3:2005+A1:2008 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee GW/1, Electronic security systems.A list of organizations represented on this committee can be obtained on request to its s
3、ecretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 91845 2 ICS Compliance with a British Standard cannot conf
4、er immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2017.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e d13.310BS EN 50131-5-3:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE
5、NORM EN 50131-5-3 March 2017 ICS 13.310 Supersedes EN 50131-5-3:2005English Version Alarm systems - Intrusion systems - Part 5-3: Requirements for interconnections equipment using radio frequency techniques Systmes dalarme - Systmes dalarme contre lintrusion - Partie 5-3: Exigences pour les quipemen
6、ts dinterconnexion utilisant des techniques radio Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 5-3: Anforderungen an bertragungsgerte, die Funkfrequenz-Techniken verwenden This European Standard was approved by CENELEC on 2016-11-14. CENELEC members are bound to comply with the CEN/CENELE
7、C Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or t
8、o any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as th
9、e official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxemb
10、ourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Nor
11、mung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50131-5-3:2017 EBS EN 50131-5-3:2017EN 50131-5-3:2017 2 Contents PageEuropean foreword . 4 1 Scope 5 2 Normat
12、ive references 5 3 Terms, definitions and abbreviated terms 5 3.1 Terms and definitions . 5 3.2 Abbreviated terms . 7 4 Requirements . 7 4.1 General . 7 4.2 Immunity to attenuation 7 4.2.1 General . 7 4.2.2 Requirement for immunity to attenuation . 7 4.3 Immunity to collision . 8 4.3.1 General . 8 4
13、.3.2 Requirement for occupation rate . 8 4.3.3 Requirement for throughput ratio 8 4.4 Immunity to substitution . 8 4.4.1 General . 8 4.4.2 Immunity to unintentional message and component substitution 8 4.4.3 Immunity to intentional messages and components substitution . 9 4.5 Immunity to interferenc
14、e . 9 4.5.1 General . 9 4.5.2 Interference outside the assigned band for equipment of all grades 9 4.5.3 Interference within the assigned band for equipment of all grades 9 4.6 Requirement for RF links monitoring 10 4.6.1 General . 10 4.6.2 Requirement for the detection of a failure of periodic comm
15、unication . 10 4.6.3 Requirement for periodic communication before setting . 10 4.6.4 Requirement for the detection of interference . 10 4.7 Antenna 11 4.7.1 General . 11 4.7.2 Requirements for antenna 11 5 Tests . 11 5.1 General . 11 5.2 Test for immunity to attenuation 12 5.3 Verification of immun
16、ity to collision 12 5.3.1 Calculation of the occupation rate . 12 5.3.2 Test for throughput ratio 13 5.4 Tests for immunity to substitution 13 5.4.1 Test for immunity to unintentional messages and components substitution 13 5.4.2 Test for immunity to intentional messages and components substitution
17、. 13 5.5 Tests for immunity to interference 13 5.5.1 General . 13 5.5.2 Test for interference outside of the assigned band (for all grades) . 14 5.5.3 Test for interference within the assigned band for equipment of all grades 14 5.5.4 Test for interference within the assigned band for grade 3 and gr
18、ade 4 equipment . 15 5.6 Tests for RF link monitoring . 15 5.6.1 Tests for the detection of a failure of periodic communication on a link 15 5.6.2 Periodic communication before setting 16 5.6.3 Tests for detection of interference 16 5.7 Test for antenna . 17 Annex A (normative) Test setup 18 BS EN 5
19、0131-5-3:2017 EN 50131-5-3:2017 3 Annex B (informative) Interference signal 19 Annex C (informative) Example for the calculation of occupation rate . 20 Figures Figure A.1 Test setup. 18 Figure B.1 Level IL . 19 Figure B.2 Interference signal 19 Tables Table 1 Immunity to attenuation . 7 Table 2 Sys
20、tem occupation of the medium . 8 Table 3 Throughput ratio . 8 Table 4 Identification codes 9 Table 5 Detection of interference timings . 10 Table 6 Detection of interference . 11 Table 7 Level of interference signal . 11 Table 8 Requirements for antenna . 11 Table 9 Duration of interference signals
21、. 16 Table C.1 Example for the calculation of occupation rate . 20 BS EN 50131-5-3:2017EN 50131-5-3:2017 4 European foreword This document (EN 50131-5-3:2017) has been prepared by CLC/TC 79 “Alarm systems”. The following dates are fixed: latest date by which this document has to be implemented atnat
22、ional level by publication of an identical national standardor by endorsement(dop) 2017-09-17 latest date by which the national standards conflicting with thisdocument have to be withdrawn(dow) 2020-03-17 This document supersedes EN 50131-5-3:2005. This document is bound to be used in conjunction wi
23、th the other parts of the EN 50131 series that define the functional requirements of the equipment regardless of the type of interconnections used. EN 50131-5 is currently composed with the following parts: CLC/FprTS 50131-5-1 Alarm systems Intrusion systems Part 5-1: Interconnections Requirements f
24、or wired Interconnection for I EN 50131-5-3, Alarm systems Intrusion systems Part 5-3: Requirements for interconnections equipment using radio frequency techniques; CLC/TS 50131-5-4, Alarm systems Intrusion and hold-up systems Part 5-4: System compatibility testing for I WD; RE; SPT. Each of the int
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50131532017ALARMSYSTEMSINTRUSIONSYSTEMSREQUIREMENTSFORINTERCONNECTIONSEQUIPMENTUSINGRADIOFREQUENCYTECHNIQUES

链接地址:http://www.mydoc123.com/p-574590.html