BS EN 50131-3-2009 Alarm systems Intrusion and hold-up systems Control and indicating equipment《报警系统 侵入和拦截系统 控制和指示设备》.pdf
《BS EN 50131-3-2009 Alarm systems Intrusion and hold-up systems Control and indicating equipment《报警系统 侵入和拦截系统 控制和指示设备》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50131-3-2009 Alarm systems Intrusion and hold-up systems Control and indicating equipment《报警系统 侵入和拦截系统 控制和指示设备》.pdf(78页珍藏版)》请在麦多课文档分享上搜索。
1、Alarm systems Intrusionand hold-up systems Part 3: Control and indicating equipmentBS EN 50131-3:2009raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsNational forewordThis British Standard is the UK implementation of EN 50131-3:200
2、9. It supersedes DD CLC/TS 50131-3:2003 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee GW/1, Electronic security systems, to Subcommittee GW/1/1,Alarm components.A list of organizations represented on this committee can be obtained onrequest to its se
3、cretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 61916 8ICS 13.310Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was publish
4、ed under the authority of the StandardsPolicy and Strategy Committee on 30 April 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 50131-3:2009EUROPEAN STANDARD EN 50131-3 NORME EUROPENNE EUROPISCHE NORM March 2009 CENELEC European Committee for Electrotechnical
5、 Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50131-
6、3:2009 E ICS 13.310 Supersedes CLC/TS 50131-3:2003English version Alarm systems - Intrusion and hold-up systems - Part 3: Control and indicating equipment Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 3: Equipement de contrle et de signalisation Alarmanlagen - Einbruch-
7、 und berfallmeldeanlagen - Teil 3: Melderzentrale This European Standard was approved by CENELEC on 2009-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any
8、 alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made
9、 by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Es
10、tonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50131-3:2009EN 50131-3:2009 2 Foreword This European Stand
11、ard was prepared by the Technical Committee CENELEC TC 79, Alarm systems. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50131-3 on 2009-02-01. This European Standard supersedes CLC/TS 50131-3:2003. The following dates were fixed: latest date
12、 by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-02-01 EN 50131 will consist of the following parts, under t
13、he general title “Alarm systems Intrusion and hold-up systems”: Part 1 System requirements Part 2-2 Intrusion detectors - Passive infrared detectors Part 2-3 Requirements for microwave detectors Part 2-4 Requirements for combined passive infrared and microwave detectors Part 2-5 Requirements for com
14、bined passive infrared and ultrasonic detectors Part 2-6 Opening contacts (magnetic) Part 2-7-1 Intrusion detectors Glass break detectors (acoustic) Part 2-7-2 Intrusion detectors Glass break detectors (passive) Part 2-7-3 Intrusion detectors Glass break detectors (active) Part 3 Control and indicat
15、ing equipment Part 4 Warning devices Part 5-3 Requirements for interconnections equipment using radio frequency techniques Part 6 Power supplies Part 7 Application guidelines Part 8Security fog device/systems _ BS EN 50131-3:2009 3 EN 50131-3:2009 Introduction This document is based on the revision
16、of the Technical Specification originally edited by the CENELEC TC 79/WG 3, then submitted to the formal vote and finally approved by CENELEC as CLC/TS 50131-3 on 2003-05-19. The work done by WG 3 is the result of the comments raised by the National Committees, members of CENELEC and of harmonisatio
17、n with EN 50131-1:2006 + A1:2009 prepared by TC 79/WG 1; for this reason the reader has to take into account EN 50131-1:2006 + A1:2009, which has to be considered as a “master” document for this EN 50131-3. Repetition of definitions and requirements contained in EN 50131-1 have been eliminated from
18、this EN 50131-3, in order to minimise conflict in the event of changes to EN 50131-1, except where repetition is deemed essential for the clarity of this document. Reference has been included to various implications arising from the detector standards. Full detail of the interconnection requirements
19、 could be the subject of a future standard. A number of requirements are contained in this standard for which a formal test procedure can only be written by defining (and hence restricting) the technology by which the requirement is achieved. Accordingly, it has been recognised that such functions c
20、an be tested only by agreement between manufacturer and test house, according to documented information relating to how the required functionality has been achieved. A table to cross reference EN 50131-1 requirements against this EN 50131-3 and tests has been included in Annex D. BS EN 50131-3:2009E
21、N 50131-3:2009 4 Contents Introduction . 3 1 Scope . 6 2 Normative references . 7 3 Definitions and abbreviations . 7 3.1 Definitions 7 3.2 Abbreviations .10 4 Equipment attributes 10 4.1 General 10 4.2 Functionality .11 5 CIE construction .11 6 Security grade .11 7 Environmental performance 11 7.1
22、Requirements .11 7.2 Environmental and EMC tests .11 8 Functional requirements 12 8.1 Inputs .12 8.2 Outputs .13 8.3 Operation .13 8.4 Processing .18 8.5 Indication 19 8.6 Notification outputs 20 8.7 Tamper security (detection/protection) 21 8.8 Interconnections .23 8.9 Timing 24 8.10 Event recordin
23、g 24 8.11 Power supply 25 9 Product documentation .25 9.1 Installation and maintenance .25 9.2 Operating instructions 26 10 Marking and labelling .26 11 Tests .26 11.1 Test conditions .27 11.2 Test procedures .28 11.3 Reduced functional test .28 11.4 Functional tests 29 11.5 Access level .40 11.6 Au
24、thorization requirements 41 11.7 Operational tests 46 11.8 Tamper security tests .56 11.9 Substitution tests 59 11.10 Testing of I or b) detail the function(s) or combination of functions that would result in the installed I b) set/unset status information for detector, security fog device, etc.; c)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5013132009ALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSCONTROLANDINDICATINGEQUIPMENT 报警 系统 侵入 拦截 控制 指示 设备
链接地址:http://www.mydoc123.com/p-574588.html