BS EN 50107-2-2005 Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Requirements for earth-leaka.pdf
《BS EN 50107-2-2005 Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Requirements for earth-leaka.pdf》由会员分享,可在线阅读,更多相关《BS EN 50107-2-2005 Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Requirements for earth-leaka.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 50107-2:2005 Signs and luminous-discharge- tube installations operating from a no-load rated output voltage exceeding 1 kV but not ex cee din g10kV Part 2: Requirements for earth-leakage and open-circuit protective devices The European Standard EN 50107-2:2005 has the status o
2、f a British Standard ICS 29.140.30 BS EN 50107-2:2005 This British Standard, was published under the authority of the Standards Policy and Strategy Committee on 29 April 2005 BSI 29 April 2005 ISBN 0 580 45944 6 National foreword This British Standard is the official English language version of EN 5
3、0107-2:2005. The UK participation in its preparation was entrusted by Technical Committee CPL/34, Lamps and related equipment, to Subcommittee CPL/34/11, Electric signs, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secret
4、ary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalog
5、ue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the
6、 text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front
7、 cover, an inside front cover, the EN title page, pages 2 to 20, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 50107-2 NORME EUROPE
8、NNE EUROPISCHE NORM April 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any
9、form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50107-2:2005 E ICS 29.140.30 English version Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2: Requirements for earth-leakage and open-
10、circuit protective devices Installation denseignes et de tubes lumineux dcharge fonctionnant une tension de sortie vide assigne suprieure 1 kV mais ne dpassant pas 10 kV Partie 2: Prescriptions pour les dispositifs de protection contre les dfauts disolement et contre louverture des circuits secondai
11、res Leuchtrhrengerte und Leuchtrhrenanlagen mit einer Leerlaufspannung ber 1 kV, aber nicht ber 10 kV Teil 2: Anforderungen an Erdschlussschutz- und Leerlaufschutzeinrichtungen This European Standard was approved by CENELEC on 2005-03-01. CENELEC members are bound to comply with the CEN/CENELEC Inte
12、rnal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC m
13、ember. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENE
14、LEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
15、Switzerland and United Kingdom. EN 50107-2:2005 - 2 - Foreword This European Standard was prepared by CENELEC BTTF 60-2, Electrical discharge lamp installations. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50107-2 on 2005-03-01. The following dates were f
16、ixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-03-01 _ - 3 - EN 50107-2:2005 Contents Pag
17、e 1 Scope5 2 Normative references5 3 Definitions5 4 General requirements .6 5 Tests .6 6 Classification .7 7 Marking.7 7.1 Items of marking7 7.2 Durability of marking7 7.3 Additional information7 8 Terminals8 9 Provision for protective earthing.8 10 Protection against accidental contact with live pa
18、rts.8 11 Moisture resistance and insulation of type B devices8 12 Electric strength9 13 Thermal endurance of devices 9 13.1 General 9 13.2 Tests for type B devices 9 13.3 Tests for type A or type C devices.9 14 Fault conditions 10 15 Construction10 16 Creepage distances and clearances.10 17 Screws,
19、current-carrying parts and connections 10 18 Resistance to heat, fire and tracking 10 19 Resistance to corrosion .10 20 Performance 10 20.1 Performance requirements for earth-leakage protective devices10 20.2 Performance requirements for open-circuit protective devices .11 EN 50107-2:2005 - 4 - 20.3
20、 Performance requirements common to both types of device11 21 Interchangeability .12 Annex A (normative) - Testing of the response time of earth-leakage protective devices 13 Annex B (informative) - An example method of measuring the performance of an earth-leakage protective device15 Annex C (norma
21、tive) - Test of the response time of open-circuit protective devices 17 Annex D (informative) - A method of measuring the performance of an open-circuit protective device.19 Figure B.1 - Typical circuit to measure the performance of an earth-leakage protective device .14 Figure D.1 - Typical circuit
22、 to measure the performance of an open-circuit protective device 18 - 5 - EN 50107-2:2005 1 Scope This European Standard specifies requirements for earth-leakage and open-circuit protective devices designed to protect circuits for neon tubes operating from transformers conforming to EN 61050 at volt
23、ages exceeding 1 000 V but not exceeding 10 000 V. NOTE 1 Requirements for the installation of earth-leakage and open-circuit protective devices are given in EN 50107-1. NOTE 2 Requirements for earth-leakage and open-circuit protective devices used with inverters and converters are specified in EN 6
24、1347-2-10. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50107-1:2002
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5010722005SIGNSANDLUMINOUSDISCHARGETUBEINSTALLATIONSOPERATINGFROMANOLOADRATEDOUTPUTVOLTAGEEXCEEDING1KVBUTNOTEXCEEDING10KVREQUIREMENTSFOREARTHLEAKAPDF

链接地址:http://www.mydoc123.com/p-574541.html