BS EN 14591-4-2007 Explosion prevention and protection in underground mines - Protective systems - Automatic extinguishing systems for road headers《地下矿井中的防爆和保护 保护系统 掘进机用自动灭火系统》.pdf
《BS EN 14591-4-2007 Explosion prevention and protection in underground mines - Protective systems - Automatic extinguishing systems for road headers《地下矿井中的防爆和保护 保护系统 掘进机用自动灭火系统》.pdf》由会员分享,可在线阅读,更多相关《BS EN 14591-4-2007 Explosion prevention and protection in underground mines - Protective systems - Automatic extinguishing systems for road headers《地下矿井中的防爆和保护 保护系统 掘进机用自动灭火系统》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 14591-4:2007Explosion prevention and protection in underground mines Protective systems Part 4: Automatic extinguishing systems for road headersICS 13.230; 73.100.99g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g
2、55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Incorporating corrigendum March 2008National forewordThis British Standard is the UK implementation of EN 14591-4:2007, incorporating corrigendum March 2008.The UK participation in its preparation was entrusted to
3、 Technical Committee FSH/23, Fire precautions in industrial and chemical plant.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its corr
4、ect application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 14591-4:2007Amendments/corrigenda issued since publicationDate Comments 30 November 2009 Implementation of CEN corrigendum March 2008. Text added to 4.2.1 and 7.1This British Standard was published
5、 under the authority of the Standards Policy and Strategy Committee on 31 August 2007 BSI 2009ISBN 978 0 580 62687 6EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14591-4July 2007ICS 13.230; 73.100.99English VersionExplosion prevention and protection in underground mines -Protective systems - Par
6、t 4: Automatic extinguishing systems forroad headersProtection contre lexplosion dans les mines souterraines -Systmes de protection - Partie 4: Installation dextinctionautomatique dexplosion pour machines attaqueponctuelleExplosionsschutz in untertgigen Bergwerken -Schutzsysteme - Teil 4: Automatisc
7、heExplosionslschanlagen fr TeilschnittmaschinenThis European Standard was approved by CEN on 9 June 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration.
8、 Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationu
9、nder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece,
10、Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre
11、: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14591-4:2007: EIncorporating corrigendum March 2008EN 14591-4:2007 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Terms an
12、d definitions .4 4 General requirements5 4.1 General5 4.2 Functional requirements.5 4.2.1 General5 4.2.2 Sensors.6 4.2.3 Extinguishing agent containers6 4.2.4 Electronic control and discharge unit .6 4.2.5 Power supply and emergency power supply6 4.3 Other requirements7 5 Special requirements 7 5.1
13、General7 5.2 Mechanical strength 7 5.3 Vibration and impact resistance 7 5.4 Maintenance-friendly design 8 6 Requirements for sensor systems.8 6.1 General8 6.2 Testing and monitoring.8 6.3 Resistance to interference/electromagnetic compatibility (EMC) 8 7 Requirements for signal-processing electroni
14、cs.8 7.1 General8 7.2 Triggering .8 7.3 Monitoring functions .9 7.4 Status displays.9 7.5 Resistance to interference/electromagnetic compatibility (EMC) 9 8 Extinguishing system9 8.1 General9 8.2 Extinguishing agent containers9 9 Marking .10 10 Information for use 10 Annex ZA (informative) Relations
15、hip between this European Standard and the Essential Requirements of EU 94/9/EC 12 Bibliography 14 BS EN 14591-4:2007EN 14591-4:2007 (E) 3 Foreword This document (EN 14591-4:2007) has been prepared by Technical Committee CEN/TC 305 “Potentially explosive atmospheres - Explosion prevention and protec
16、tion”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2008, and conflicting national standards shall be withdrawn at the latest by January 2008. T
17、his document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directives. For relationship with EU Directives, see informative Annex ZA, which is an integral part of this document. This Europe
18、an Standard consists of the following Parts: EN 15491-1, Explosion prevention and protection in underground mines Protective systems Part 1: 2-bar explosion proof ventilation structures EN 15491-2, Explosion prevention and protection in underground mines Protective systems Part 2: Passive water trou
19、gh barriers EN 14591-4, Explosion prevention and protection in underground mines Protective systems Part 4: Automatic extinguishing systems for road headers According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this
20、European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the Un
21、ited Kingdom. BS EN 14591-4:2007EN 14591-4:2007 (E) 4 1 Scope This document lays down requirements for automatic explosion extinguishing systems for roadheader machines (selective cut heading machines) in roadheader drivages where these systems automatically detect the initial phase of a firedamp ex
22、plosion which has been initiated by the cutter head of a roadheader machine and extinguish it at the roadhead in such a way that the roadway drivage team is not put at risk. This document does not lay down any requirements for the fighting of fires at the roadhead. The automatic explosion extinguish
23、ing system for roadheaders is an autonomous protective system designed in accordance with Directive 94/9/EC. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references,
24、 the latest edition of the referenced document (including any amendments) applies. EN 1127-2:2002, Explosive atmospheres Explosion prevention and protection Basic concepts and methodology for mining EN 10025 (all Parts), Hot rolled products of structural steels EN 10204, Metallic products Types of i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN1459142007EXPLOSIONPREVENTIONANDPROTECTIONINUNDERGROUNDMINESPROTECTIVESYSTEMSAUTOMATICEXTINGUISHINGSYSTEMSFORROADHEADERS

链接地址:http://www.mydoc123.com/p-572562.html