BS EN 14435-2004 Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only - Re.pdf
《BS EN 14435-2004 Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only - Re.pdf》由会员分享,可在线阅读,更多相关《BS EN 14435-2004 Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only - Re.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 14435:2004 Respiratory protective devices Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Requirements, testing, marking The European Standard EN 14435:2004 has the status of a British Standard ICS 1
2、3.340.30 BS EN 14435:2004 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 2 December 2004 BSI 2 December 2004 ISBN 0 580 44938 6 National foreword This British Standard is the official English language version of EN 14435:2004. The UK partici
3、pation in its preparation was entrusted by Technical Committee PH/4, Respiratory protection, to Subcommittee PH/4/6, Self contained breathing apparatus, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. WARNING The
4、UK as a member of CEN, is obliged to publish EN 14435:2004 as a British Standard. However, attention is drawn to the fact that during the development of this European Standard, the UK consistently voted against its approval as a European Standard. The reason for this disapproval is as follows. The S
5、cope of EN 14435:2004 states that this standard “ specifies minimum performance requirements for self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only. This European Standard does not apply to escape apparatus, diving apparatus
6、and apparatus used for fire fighting.” During discussion of this standard by BSI Committee PH/4/6, which mirrors the work of CEN Committee, TC79/SC6, the UK committee expressed the opinion that the self-contained open-circuit compressed air breathing apparatus with half mask is not a safe combinatio
7、n to be used in those emergency situations where wearers may be exposed to other conditions (such as exposure in confined spaces to, or leaks of, noxious or toxic substances) that will, on the basis of a risk assessment in accordance with The Control of Substances Hazardous to Health Regulations 200
8、2, require the combination to meet higher minimum performance requirements for the protection of the wearer. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “Intern
9、ational Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a Bri
10、tish Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international a
11、nd European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 27, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last iss
12、ued. Amendments issued since publication Amd. No. Date Comments EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14435 August 2004 ICS 13.340.30 English version Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with
13、 positive pressure only - Requirements, testing, marking Appareils de protection respiratoire - Appareils de protection respiratoire isolants autonomes circuit ouvert, air comprim avec un demi-masque conus exclusivement pour une utilisation en pression positive - Exigences, essais, marquage Atemschu
14、tzgerte - Behltergerte mit Druckluft (Pressluftatmer) mit Halbmaske zum Gebrauch fr berdruck - Anforderungen, Prfung, Kennzeichnung This European Standard was approved by CEN on 19 May 2004. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for
15、giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official v
16、ersions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgiu
17、m, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMI
18、T EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2004 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14435:2004: EEN 14435:2004 (E) 2 Contents page Foreword5 Introduc
19、tion .6 1 Scope 7 2 Normative References.7 3 Terms and definitions .7 4 Description .7 5 Requirements.8 5.1 General8 5.2 Ergonomics 8 5.3 Design .8 5.4 Materials .9 5.5 Cleaning and disinfecting .9 5.6 Mass 9 5.7 Connections .9 5.7.1 General9 5.7.2 Couplings (if fitted)9 5.7.3 Strength of connection
20、s to half mask, demand valve and breathing hose (if fitted) .10 5.7.4 Connection between apparatus and half mask 10 5.7.5 High, medium and low pressure connections 10 5.8 Half mask 10 5.9 Body harness .10 5.10 Practical performance .10 5.11 Resistance to temperature and flammability 11 5.11.1 Temper
21、ature performance 11 5.11.2 Flammability.11 5.12 Protection against particulate matter 11 5.13 High and medium pressure parts.12 5.14 Pressure vessel12 5.15 Pressure vessel valve(s) .12 5.16 Pressure reducer .12 5.16.1 General12 5.16.2 Apparatus with a pressure reducer safety valve12 5.16.3 Apparatu
22、s without a pressure reducer safety valve 13 5.17 Pressure indicator and tube .13 5.17.1 General13 5.17.2 Pressure indicator of the pointer type.13 EN 14435:2004 (E) 3 5.17.3 Pressure indicator of the tactile type 13 5.17.4 Electronic pressure indicator.14 5.18 Warning device 14 5.18.1 General14 5.1
23、8.2 Pneumatic warning device14 5.18.3 Electronic warning device 14 5.19 Flexible hoses and tubes15 5.19.1 Breathing hose.15 5.19.2 Medium pressure connecting tube15 5.20 Lung governed demand valve15 5.20.1 General15 5.20.2 Leaktightness.15 5.21 Breathing resistance .15 5.21.1 Inhalation resistance.1
24、5 5.21.2 Exhalation resistance16 5.22 Static pressure.16 6 Testing 16 6.1 General16 6.2 Nominal values and tolerances16 6.3 Visual inspection .16 6.4 Resistance to temperature and flammability16 6.4.1 Laboratory tests with a breathing machine 16 6.4.2 Practical performance test .17 6.5 Pressure redu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN144352004RESPIRATORYPROTECTIVEDEVICESSELFCONTAINEDOPENCIRCUITCOMPRESSEDAIRBREATHINGAPPARATUSWITHHALFMASKDESIGNEDTOBEUSEDWITHPOSITIVEPRESSUREONLYREPDF

链接地址:http://www.mydoc123.com/p-572448.html