BS EN 13798-2010 Hydrometry - Specification for a reference raingauge pit《水文观测 基准量雨槽规范》.pdf
《BS EN 13798-2010 Hydrometry - Specification for a reference raingauge pit《水文观测 基准量雨槽规范》.pdf》由会员分享,可在线阅读,更多相关《BS EN 13798-2010 Hydrometry - Specification for a reference raingauge pit《水文观测 基准量雨槽规范》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 13798:2010Hydrometry Specification fora reference raingauge pitBS EN 13798:2010 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 13798:
2、2010. Itsupersedes BS EN 13798:2002 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee CPI/113, Measuring instruments and equipment. A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not
3、purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2010 ISBN 978 0 580 65159 5 ICS 07.060 Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theSta
4、ndards Policy and Strategy Committee on 31 July 2010 Amendments issued since publicationDate T e x t a f f e c t e dBS EN 13798:2010EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13798 June 2010 ICS 07.060 Supersedes EN 13798:2002English Version Hydrometry - Specification for a reference raing
5、auge pit Hydromtrie - Spcification pour une fosse de rfrence dinstallation dun pluviomtre Hydrometrie - Spezifikation fr eine Grube fr Referenz-Regenmesser This European Standard was approved by CEN on 26 May 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipu
6、late the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard
7、exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standar
8、ds bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and Uni
9、ted Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13798:2010:
10、 EBS EN 13798:2010EN 13798:2010 (E) 2 Contents Page Foreword 3Introduction .41 Scope 52 Design and construction of the reference raingauge pit .53 Design and construction of the grating.54 Installation of raingauges .5Bibliography . 12BS EN 13798:2010EN 13798:2010 (E) 3 Foreword This document (EN 13
11、798:2010) has been prepared by Technical Committee CEN/TC 318 “Hydrometry”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2010, and conflicting
12、national standards shall be withdrawn at the latest by December 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document su
13、persedes EN 13798:2002. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, H
14、ungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 13798:2010EN 13798:2010 (E) 4 Introduction A raingauge pit consists of a pit, normally square in plan an
15、d of suitable depth, and a grating, normally of galvanised sheet steel or plastic. Such a pit can contain any suitable type of raingauge. The pit gauge may be used in its own right for improved measurement of rainfall, for wind effects evaluation or for comparison purposes against other reference ra
16、ingauges. BS EN 13798:2010EN 13798:2010 (E) 5 1 Scope This European Standard specifies the design of a reference raingauge pit. The reference raingauge pit is designed for the liquid precipitation only. The specified details of the pit and the grating, are purposely kept to a minimum in order to all
17、ow each raingauge operator latitude in their construction and to suit local conditions. 2 Design and construction of the reference raingauge pit Figures 1 to 6 show the design of the pit, including the required dimensions of the pit and the grating, and the method of installation of the raingauge. T
18、he specified dimensions are not critical, but shall be used whenever possible. Variations are acceptable within the indicated tolerances. The pit shall preferably be sited on level ground to avoid possible surface runoff into it during prolonged heavy rain. However, in mountainous areas, this may no
19、t be possible or desirable and adequate drainage shall be provided in such cases. The sides of the pit shall be formed of brick, concrete, corrugated iron, plastic, preserved wood or other suitable material. They shall be supported to prevent collapse. Supports shall be provided around the edges, or
20、 at the corners of the pit, on which to rest the grating. The grating shall either be strong enough to walk on, or be made in two sections to allow half to be lifted, to give access to the raingauge. The base of the pit shall be adapted and deep enough to allow the correct installation of the rainga
21、uge and the levelling. The base of the pit shall also allow water to drain. For drainage an overlay of gravel or other suitable material may be used but for high precipitation rate places a suitable pumping system may be used. It may be located in a central recess (extra depth). Plastic sheeting lai
22、d over bare soil shall not be used if it does not permit water to drain quickly away. Weed growth shall be prevented either by weeding or by periodic application of weed killer. The surrounding grass should be maintained well and kept without weed. The maximum height of the grass should not exceed 2
23、 cm. The gratings shall be kept free of debris, (cut) grass and leaves. The pit shall be at least 300 mm deep. 3 Design and construction of the grating The grating shall be constructed from material sufficiently strong to maintain its shape without distortion. The strips of the grating shall be not
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN137982010HYDROMETRYSPECIFICATIONFORAREFERENCERAINGAUGEPIT 水文 观测 基准 量雨槽 规范 PDF

链接地址:http://www.mydoc123.com/p-571881.html