《BS EN 13125-2001 Shutters and blinds - Additional thermal resistance - Allocation of a class of air permeability to a product《遮板和百叶窗 补充的耐热性 产品透气率等级的规定》.pdf》由会员分享,可在线阅读,更多相关《BS EN 13125-2001 Shutters and blinds - Additional thermal resistance - Allocation of a class of air permeability to a product《遮板和百叶窗 补充的耐热性 产品透气率等级的规定》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 13125:2001 Shutters and blinds Additional thermal resistance Allocation of a class of air permeability to a product The European Standard EN 13125:2001 has the status of a British Standard ICS 91.060.50 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS E
2、N 13125:2001 This British Standard, having been prepared under the direction of the Sector Committee for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 June 2001 BSI 06-2001 ISBN 0 580 37154 9 National foreword This British St
3、andard is the official English language version of EN 13125:2001. The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/3, Domestic shutters and blinds, which has the responsibility to: A list
4、 of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “Internati
5、onal Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a Brit
6、ish Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European dev
7、elopments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 15 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publicatio
8、n Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN13125 April2001 ICS91.060.50;91.120.10 Englishversion ShuttersandblindsAdditionalthermalresistanceAllocation ofaclassofairpermeabilitytoaproduct Fermeturespourbaiesquipesdefentres,stores intrieursetextrieursRsistancethermiquead
9、ditionnelle Attributionduneclassedepermabilitlairunproduit AbschlsseZustzlicherWrmedurchlasswiderstand ZuordnungeinerLuftdurchlssigkeitsklassezueinem Produkt ThisEuropeanStandardwasapprovedbyCENon8March2001. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsfo
10、rgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheManagementCentreortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversionin
11、anyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheManagementCentrehasthesamestatusasthe official versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Iceland,Ireland,Italy,Luxembou
12、rg,Netherlands,Norway,Portugal,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2001CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMem
13、bers. Ref.No.EN13125:2001EPage2 EN13125:2001 CONTENTS Page Foreword 3 1 Scope 3 2 Normativereferences. 3 3 Termsanddefinitions 4 4 ShuttersAllocationofairpermeabilityclasses . 4 4.1 Criteriaforclassesallocation 4 4.2 Minimumclassesadmittedwithoutassessment . 7 4.3 Conditionsofallocationofclass5 7 5
14、Externalblinds,internalblinds,blindsincorporatedintotheglazing Allocationofairpermeabilityclasses. 9 5.1 Criteriaforclassallocation . 9 5.2 Externalblinds 9 5.3 Internalblindsandblindsincorporatedintotheglazing 10 5.4 Blindswithonesidewithlowemissivitycoating 11 6 Presenceofatopbox(caseofrollershutt
15、er) 11 6.1 Topboxindependentofwindowframe(rollershutterforsubsequentinstallationfor instance). 11 6.2 Topboxinstalledinsidethemasonry(seeFigure3a)orwiththeframing(see Figure3b). 11 ANNEXA (normative) ThermalresistanceofPVCprofilescurtain 13 ANNEXB (informative)Usualvaluesofperipheralgapsforinteriorb
16、lindsand blindsincorporatedintotheglazing 14Page3 EN13125:2001 Foreword ThisEuropeanStandardhasbeenpreparedbyTechnicalCommitteeCEN/TC33 “Doors,Windows,Shutters,BuildingHardwareandCurtainWalling“thesecretariat ofwhichisheldbyAFNOR. ThisEuropeanStandardshallbegiventhestatusofanationalstandard,eitherby
17、 publicationofanidenticaltextorbyendorsement,atthelatestbyOctober2001,and conflictingnationalstandardsshallbewithdrawnatthelatestbyOctober2001. Itisapartofaseriesofstandardsdealingwithblindsandshuttersforbuildingsas definedinprEN12216:1995. AnnexAisnormativeandannexBisinformative. AccordingtotheCEN/
18、CENELECInternalRegulations,thenationalstandards organizationsofthefollowingcountriesareboundtoimplementthisEuropean Standard:Austria,Belgium,CzechRepublic,Denmark,Finland,France,Germany, Greece,Iceland,Ireland,Italy,Luxembourg,Netherlands,Norway,Portugal,Spain, Sweden,SwitzerlandandtheUnitedKingdom.
19、 1 Scope ThisEuropeanStandardspecifiestheclassificationcriteriaofshuttersandinternal andexternalblindsinrelationwiththeirairpermeabilityforthecalculationof additionalthermalresistancegivenbytheseproductsaccordingtoENISO100771. Thisstandardappliestoshuttersandblindsfittedtoawindow,aFrenchwindowora cu
20、rtainwallinginsuchawaythatinextendedandclosedpositiontheyincloseanair layerofthicknessroughlyconstantbetween15mmand300mm(shuttersandblinds paralleltothewindowortothefaade). Thisstandardappliestothefollowingshuttersandblinds: Shutters:rollershutter,externalvenetienblind,wingshutter,slidingpanel shutt
21、er,venetianshutter,concertinashutter,flatclosingconcertinashutter; Externalblinds :verticalawning,facadeawning,conservatoryawning; Internalblinds :venetianblind,rollerblind,verticalblind,pleatedblind; Blindsincorporatedintoglazing. 2 Normativereferences ThisEuropeanStandardincorporatesbydatedorundat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN131252001SHUTTERSANDBLINDSADDITIONALTHERMALRESISTANCEALLOCATIONOFACLASSOFAIRPERMEABILITYTOAPRODUCT

链接地址:http://www.mydoc123.com/p-571122.html