BS EN 13111-2010 Flexible sheets for waterproofing - Underlays for discontinuous roofing and walls - Determination of resistance to water penetration《挠性防水板 非连续屋面和墙面的垫物 抗渗水性测定》.pdf
《BS EN 13111-2010 Flexible sheets for waterproofing - Underlays for discontinuous roofing and walls - Determination of resistance to water penetration《挠性防水板 非连续屋面和墙面的垫物 抗渗水性测定》.pdf》由会员分享,可在线阅读,更多相关《BS EN 13111-2010 Flexible sheets for waterproofing - Underlays for discontinuous roofing and walls - Determination of resistance to water penetration《挠性防水板 非连续屋面和墙面的垫物 抗渗水性测定》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 13111:2010ICS 91.100.50NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDFlexible sheetsfor waterproofing Underlays fordiscontinuousroofing and walls Determination ofresistance to waterpenetrationThis British Standardwas published under theauthority of the S
2、tandardsPolicy and StrategyCommittee on 30 June2010 BSI 2010ISBN 978 0 580 68722 8Amendments/corrigenda issued since publicationDate CommentsBS EN 13111:2010National forewordThis British Standard is the UK implementation of EN 13111:2010. Itsupersedes BS EN 13111:2001 which is withdrawn.The UK parti
3、cipation in its preparation was entrusted to TechnicalCommittee B/546/5, Flexible building membranes.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are resp
4、onsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS EN 13111:2010EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13111 May 2010 ICS 91.100.50 Supersedes EN 13111:2001English Version Flexible sheets for waterproofing - Underlays
5、for discontinuous roofing and walls - Determination of resistance to water penetration Feuilles souples dtanchit - Ecrans de sous-toiture et pare-pluie pour murs - Dtermination de la rsistance la pntration de leau Abdichtungsbahnen - Unterdeck- und Unterspannbahnen fr Dachdeckungen und Wnde - Bestim
6、mung des Widerstandes gegen Wasserdurchgang This European Standard was approved by CEN on 23 April 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration
7、. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translati
8、on under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, G
9、ermany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORM
10、UNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13111:2010: EBS EN 13111:2010EN 13111:2010 (E) 2 Contents Page Foreword 3Introduction .41 Scope 52 Normative references 5
11、3 Terms and definitions .54 Principle 55 Apparatus .56 Sampling and preparation of test specimens .66.1 Sampling .66.2 Preparation of test specimens .67 Procedure .78 Evaluation of results .79 Test Report .7BS EN 13111:2010EN 13111:2010 (E) 3 Foreword This document (EN 13111:2010) has been prepared
12、by Technical Committee CEN/TC 254 “Flexible sheets for waterproofing”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2010, and conflicting natio
13、nal standards shall be withdrawn at the latest by November 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document superse
14、des EN 13111:2001. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European
15、Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the Un
16、ited Kingdom. BS EN 13111:2010EN 13111:2010 (E) 4 Introduction This European Standard is one of a series of standards which specify test methods for the characterization and/or classification of industrially manufactured underlays. The methods of rest relate to products exclusively. This document ap
17、plies in conjunction with European Standards specifying definitions and characteristics on underlays for discontinuous roofing and walls. BS EN 13111:2010EN 13111:2010 (E) 5 1 Scope This European Standard specifies a method to test the resistance against water penetration of underlays for discontinu
18、ous roofing and for walls. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
19、 EN 13416, Flexible sheets for waterproofing Bitumen, plastic and rubber sheets for roof waterproofing Rules for sampling 3 Terms and definitions For the purposes of this document, the terms and definitions indicated in the corresponding European Standards specifying definitions and characteristics
20、on underlays for discontinuous roofing and walls apply. 4 Principle Test specimens of the sheet are subjected to a waterhead and the volume of penetrating water is measured. A conditioned test specimen is positioned as a water-carrying layer into a device with flange and defined basic surface. Water
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN131112010FLEXIBLESHEETSFORWATERPROOFINGUNDERLAYSFORDISCONTINUOUSROOFINGANDWALLSDETERMINATIONOFRESISTANCETOWATERPENETRATION

链接地址:http://www.mydoc123.com/p-571108.html