BS EN 12211-2016 Windows and doors Resistance to wind load Test method《窗和门 抗风性 试验方法》.pdf
《BS EN 12211-2016 Windows and doors Resistance to wind load Test method《窗和门 抗风性 试验方法》.pdf》由会员分享,可在线阅读,更多相关《BS EN 12211-2016 Windows and doors Resistance to wind load Test method《窗和门 抗风性 试验方法》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 12211:2016Windows and doors Resistance to wind load TestmethodBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 12211:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 12211:2016. It supersedes BS EN 12211:2000 which
2、 is withdrawn.The UK participation in its preparation was entrusted to Technical Committee B/538/1, Windows and doors.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contr
3、act. Users are responsible for its correct application. The British Standards Institution 2016 .Published by BSI Standards Limited 2016ISBN 978 0 580 84016 6 ICS 91.060.50 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the a
4、uthority of the Standards Policy and Strategy Committee on 30 June 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 12211:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12211 March 2016 ICS 91.060.50 Supersedes EN 12211:2000English Version Windows and do
5、ors - Resistance to wind load - Test method Fentres et portes - Rsistance au vent - Mthode dessai Fenster und Tren - Widerstandsfhigkeit bei Windlast - Prfverfahren This European Standard was approved by CEN on 9 January 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations
6、 which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. Thi
7、s European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN memb
8、ers are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portug
9、al, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form
10、 and by any means reserved worldwide for CEN national Members. Ref. No. EN 12211:2016 EBS EN 12211:2016EN 12211:2016 (E) 2 Contents Page European foreword . 3 1 Scope 4 2 Normative references 4 3 Terms and definitions . 4 4 Principles of test 5 5 Apparatus . 5 6 Preparation of test specimen 6 6.1 Se
11、t-up of the test specimen 6 6.2 Set-up of measuring devices for frontal deflection . 6 7 Test procedure . 6 7.1 Preliminaries 6 7.2 Deflection test. 7 7.2.1 General 7 7.2.2 Positive pressure . 7 7.2.3 Negative pressure . 7 7.3 Repeated pressure test . 7 7.4 Safety test . 7 8 Deflection . 8 9 Repeate
12、d pressure 8 10 Safety test . 8 11 Test report . 8 Annex A (informative) Deflection measurements . 10 Annex B (informative) Resistance to wind load test sequence . 14 Bibliography . 15 BS EN 12211:2016EN 12211:2016 (E) 3 European foreword This document (EN 12211:2016) has been prepared by Technical
13、Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2016, an
14、d conflicting national standards shall be withdrawn at the latest by September 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. T
15、his document supersedes EN 12211:2000. The revision of this European Standard clarifies only the test method and does not affect existing test evidence of EN 12211:2000. This European Standard is one of a series of standards for windows and doors. In comparison with EN 12211:2000, the following sign
16、ificant changes were made: a) Clause 3: Supplement of definition “closing condition”; b) Sub-clause 3.2: Simplification of definition “test pressure”; c) Sub-clause 5.4: Revision of definition accuracy“; d) Sub-clause 7.1: Addition of closing condition“; e) Clause 11: Supplement of necessary descrip
17、tion of test specimen; f) Annex A: Renumeration of figures; g) Annex A: Revision of A.1 and A.2; h) Annex A: Supplement of Figure A.4 (new) Measuring points on single and double leaf doors (example); i) Annex B: Revision of Figure B.1. According to the CEN/CENELEC Internal Regulations, the national
18、standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuani
19、a, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 12211:2016EN 12211:2016 (E) 4 1 Scope This European Standard defines the test method to determine the resistance to wind load for completely asse
20、mbled windows and pedestrian doorsets of any materials when submitted to positive or negative test pressures. This test method is designed to take account of conditions in use, when the window or door is installed in accordance with the manufactures specification and the requirements of relevant Eur
21、opean Standards and codes of practice. This European Standard does not apply to joints between the window or door frame and the building construction. This European Standard is not intended to evaluate strength of the glass. 2 Normative references The following documents, in whole or in part, are no
22、rmatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1026, Windows and doors Air permeability Test method EN
23、12519, Windows and pedestrian doors Terminology 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12519 and the following apply. 3.1 closing condition 3.1.1 closed movable parts rest in or at the fixed parts in a way in which they may be fastened (latch
24、ed and/or locked) 3.1.2 fastened where the movable part is restrained at one or more points and shall be described by at least one of the two as listed below 3.1.2.1 latched movable part is returned to its closed position and restrained by either a) a self - engaging fastener or b) a roller catch or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN122112016WINDOWSANDDOORSRESISTANCETOWINDLOADTESTMETHOD 抗风性 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-570153.html