BS EN 12179-2000 Curtain walling - Resistance to wind load - Test method《幕墙 抗风性 试验方法》.pdf
《BS EN 12179-2000 Curtain walling - Resistance to wind load - Test method《幕墙 抗风性 试验方法》.pdf》由会员分享,可在线阅读,更多相关《BS EN 12179-2000 Curtain walling - Resistance to wind load - Test method《幕墙 抗风性 试验方法》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS EN 12179:2000 The Euro
2、pean Standard EN 12179:2000 has the status of a British Standard ICS 91.060.10 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Curtain walling Resistance to wind load Test methodThis British Standard, having been prepared under the direction of the Sector Committee for Buildin
3、g and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 August 2000 BSI 08-2000 ISBN 0 580 35787 2 BS EN 12179:2000 Amendments issued since publication Amd. No. Date Comments National foreword This British Standard is the official English lan
4、guage version of EN 12179:2000. The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/6, Curtain walling, which has the responsibility to: aid enquirers to understand the text; present to the
5、responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request
6、to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the B
7、SI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summar
8、y of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 9 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12179 June 2000 ICS 91.060.1
9、0 English version Curtain walling - Resistance to wind load - Test method Faades rideaux Rsistance la pression du vent Mthode dessai Vorhangfassaden Widerstand gegen Windlast Prfverfahren This European Standard was approved by CEN on 6 October 1999. CEN members are bound to comply with the CEN/CENEL
10、EC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Uptodate lists and bibliographical references concerning s uch national standards may be obtained on application to the Central Secretariat or to any CEN
11、 member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN me
12、mbers are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISA
13、TION EUROPISCHES KOMITEE FR NORMUNG Central Secretariat: rue de Stassart, 36 B-1050 Brussels 2000 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12179:2000 EPage 2 EN 12179:2000 BSI 082000 Contents Foreword 3 1 Scope 4 2 Normative
14、 references4 3 Definitions.4 4 Principle5 5 Apparatus5 6 Test specimen.6 7 Test preparation6 8 Test procedure6 9 Results7 10 Test report.7Page 3 EN 12179:2000 BSI 082000 Foreword This European Standard has been prepared by Technical Committee CEN/TC 33, Doors, windows, shutters, building hardware an
15、d curtain walling, the Secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2000, and conflicting national standards shall be withdrawn at the latest by
16、December 2000. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlan
17、ds, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. This European Standard forms part of a series of curtain walling tests as defined in the product standard prEN 13830:2000.Page 4 EN 12179:2000 BSI 082000 1 Scope This standard defines the method for determining the resistance t
18、o wind load of curtain walling, both its fixed and openable parts, under postive and negative static air pressure. NOTE This standard applies to any curtain walling product as defined in prEN 13830:2000. 2 Normative references This European Standard incorporates by dated or undated reference, provis
19、ions from other publications. These normative references are cited at the appropriate points in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these listed publications apply to this European Standard only when incorporated i
20、nto it by amendment or revision. For undated references the latest edition of the publication referred to applies. prEN 13119: 1997 Curtain walling - Terminology. prEN 13116: 1997 Curtain walling Resistance to wind load Performance requirements. ENV 1991-2-4 Eurocode 1: Basis of design and actions o
21、n structures Part 24: Actions on structures Wind actions. 3 Definitions For the purposes of this standard, the definitions given in prEN 13119:1997, together with the following, apply. 3.1 test pressure differential pressure between the two faces of the test specimen, expressed in Pascal (Pa) 3.2 po
22、sitive pressure when outer face is subjected to higher pressure than inner face 3.3 negative pressure when inner face is subjected to higher pressure than outer face 3.4 design wind load load calculated following the procedure specified within ENV 199124 and represented in this test with positive an
23、d negative test pressures on the test specimen 3.5 increased load (safety load) 1,5 times design wind load expressed in PascalPage 5 EN 12179:2000 BSI 082000 3.6 residual deformation change in shape or dimension which does not disappear when the test pressure is removed 3.7 frontal displacement move
24、ment of a point on a member measured normal to the member3.8 frontal deflection maximum frontal displacement of a member, minus half the sum of the frontal displacement at each end of the member 4 Principle Application of a sequence of test pressures (positive and negative) with displacements measur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN121792000CURTAINWALLINGRESISTANCETOWINDLOADTESTMETHOD 幕墙 抗风性 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-570123.html