BS EN 868-9-2009 Packaging for terminally sterilized medical devices - Uncoated nonwoven materials of polyolefines - Requirements and test methods《最终灭菌医疗器械的包装 聚烯烃非包覆非织物材料 试验方法和要求》.pdf
《BS EN 868-9-2009 Packaging for terminally sterilized medical devices - Uncoated nonwoven materials of polyolefines - Requirements and test methods《最终灭菌医疗器械的包装 聚烯烃非包覆非织物材料 试验方法和要求》.pdf》由会员分享,可在线阅读,更多相关《BS EN 868-9-2009 Packaging for terminally sterilized medical devices - Uncoated nonwoven materials of polyolefines - Requirements and test methods《最终灭菌医疗器械的包装 聚烯烃非包覆非织物材料 试验方法和要求》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 , -.-!“/00! !“#$ %*+ Part 3: Paper for use in the manufacture of paper bags (specified in EN 868-4) and in the manufacture of pouches and reels (specified in EN 868-5) Requirements and test methods; Part 4: Paper bags Requirements and test methods; Part 5: Sealable pouches and reels of porous mater
2、ials and plastic film construction Requirements and test methods; Part 6: Paper for low temperature sterilization processes Requirements and test methods; Part 7: Adhesive coated paper for low temperature sterilization processes Requirements and test methods; Part 8: Re-usable sterilization containe
3、rs for steam sterilizers conforming to EN 285 Requirements and test methods; Part 9: Uncoated nonwoven materials of polyolefines Requirements and test methods; Part 10: Adhesive coated nonwoven materials of polyolefines Requirements and test methods. In addition, ISO/TC 198 “Sterilization of health
4、care products“ in collaboration with CEN/TC 102 “Sterilizers for medical purposes“ has prepared the EN ISO 11607 series “Packaging for terminally sterilized medical devices“. The EN ISO 11607 series specifies general requirements for materials, sterile barrier systems and packaging systems (Part 1)
5、and validation requirements for forming, sealing and assembly processes (Part 2). According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denm
6、ark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 868-9:2009EN 868-9:2009 (E) 4 Introduction The EN ISO 1
7、1607 series consists of two parts under the general title “Packaging for terminally sterilized medical devices“. Part 1 of this series specifies general requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to
8、maintain sterility of terminally sterilized medical devices to the point of use. Part 2 of this series specifies validation requirements for forming, sealing and assembly processes. Every sterile barrier system shall fulfil the requirements of EN ISO 11607-1. The EN 868 series can be used to demonst
9、rate compliance with one or more of the requirements specified in EN ISO 11607-1. During the revision of EN 868 parts 2 to 10 CEN/TC 102/WG 4 recognized Resolution CEN/BT 21/2003 relating to the implementation of the uncertainty of measurement concept in standards. Following this Resolution and the
10、corresponding guidance, CEN/TC 102/WG 4 has initiated a review of the test methods needed to show compliance with the requirements specified in EN 868 parts 2 to 10 with the intention that the information required by CEN/BT 21/2003 be available for inclusion in EN 868 parts 2 to 10 during one of the
11、ir next revisions. CEN/TC 102/WG 4 also appreciates the initiatives of CEN with regard to the minimization of adverse environmental impacts by standards. It was agreed that this subject should be given priority during the next edition of the EN ISO 11607 series that is the basic reference for all pa
12、rts of the EN 868 series. BS EN 868-9:2009EN 868-9:2009 (E) 5 1 Scope This part of EN 868 provides test methods and values for uncoated nonwoven materials of polyolefines used for sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medica
13、l devices to the point of use. NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user. This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add or modify the
14、general requirements specified in EN ISO 11607-1. As such, the particular requirements in 4.2 to 4.3 can be used to demonstrate compliance with one or more but not all of the requirements of EN ISO 11607-1. NOTE 2 When additional materials are used inside the sterile barrier system in order to ease
15、the organization, drying or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) then other requirements, including the determination of the acceptability of these materia
16、ls during validation activities, may apply. The materials specified in this part of EN 868 are intended for single use only. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For und
17、ated references, the latest edition of the referenced document (including any amendments) applies. EN 20811, Textiles Determination of resistance to water penetration Hydrostatic pressure test EN 21974, Paper Determination of tearing resistance (Elmendorf method) (ISO 1974:1990) EN ISO 536, Paper an
18、d board Determination of grammage (ISO 536:1995) EN ISO 1924-2, Paper and board Determination of tensile properties Part 2: Constant rate of elongation method (ISO 1924-2:1994) EN ISO 2758, Paper Determination of bursting strength (ISO 2758:2001) EN ISO 11607-1:2006, Packaging for terminally sterili
19、zed medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems (ISO 11607-1:2006) ISO 5636-3, Paper and board Determination of air permeance (medium range) Part 3: Bendtsen method ISO 6588-2, Paper, board and pulps Determination of pH of aqueous extracts Part 2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN86892009PACKAGINGFORTERMINALLYSTERILIZEDMEDICALDEVICESUNCOATEDNONWOVENMATERIALSOFPOLYOLEFINESREQUIREMENTSANDTESTMETHODS

链接地址:http://www.mydoc123.com/p-552420.html