BS EN 303-7-2006 Heating boilers - Part 7 Gas-fired central heating boilers nequipped with a forced draught burner of nominal heat output not exceeding 1 000 kW《加热锅炉 第7部分 用标称热输出小于等.pdf
《BS EN 303-7-2006 Heating boilers - Part 7 Gas-fired central heating boilers nequipped with a forced draught burner of nominal heat output not exceeding 1 000 kW《加热锅炉 第7部分 用标称热输出小于等.pdf》由会员分享,可在线阅读,更多相关《BS EN 303-7-2006 Heating boilers - Part 7 Gas-fired central heating boilers nequipped with a forced draught burner of nominal heat output not exceeding 1 000 kW《加热锅炉 第7部分 用标称热输出小于等.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 303-7:2006Heating boilers Part 7: Gas-fired central heating boilers equipped with a forced draught burner of nominal heat output not exceeding 1 000 kWThe European Standard EN 303-7:2006 has the status of a British StandardICS 91.140.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g4
2、3g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Tue Apr 03 07:10:06 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 303-7:2006This British Standard was published
3、 under the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 0 580 49826 3National forewordThis British Standard was published by BSI. It is the UK implementation of EN 303-7:2006. The UK participation in its preparation was entrusted to Technical Committee GSE
4、/29, Gas-fired central heating boilers (domestic and non-domestic) and domestic gas-fired water heaters.A list of organizations represented on GSE/29 can be obtained on request to its secretary.EN 303-7:2006 is a candidate “harmonized” European standard and fully takes into account the requirements,
5、 given under the EU gas appliances (90/396/EEC) and boiler efficiency (92/42/EEC) Directives, and intended to lead to CE marking. The date of applicability of EN 303-7:2006 as a harmonized European standard, i.e. the date after which this standard may be used for CE marking purposes, is subject to a
6、n announcement in the Official Journal of the European Communities. The Commission in consultation with Member States has agreed a transition period for the co-existence of harmonized European standards and their corresponding national standard(s). It is intended that this period will comprise a per
7、iod, usually nine months, after the date of availability of the European Standard, during which any required changes to national regulations are to be made, followed by a further period, usually of 12 months, for the implementation of CE marking. At the end of this co-existence period, the national
8、standard(s) will be withdrawn. In the UK, there are no corresponding national standards. The UK as a member of CEN is obliged to publish EN 303-7:2006 as a British Standard. However, attention is drawn to the fact that during the development of this European standard, the UK consistently voted again
9、st its approval as a European standard. The reason for this disapproval and additional information is given in National Annex NA.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standa
10、rd cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Tue Apr 03 07:10:06 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 303-7October 2006ICS 91.140.10English VersionHeating
11、boilers - Part 7: Gas-fired central heating boilersequipped with a forced draught burner of nominal heat outputnot exceeding 1 000 kWChaudire de chauffage - Partie 7 : Chaudires dechauffage central quipes dun brleur air soufflutilisant les combustibles gazeux de puissance utileinfrieure ou gale 1 00
12、0 kWHeizkessel - Teil 7 : Zentralheizkessel fr gasfrmigeBrennstoffe mit einer Geblsebrenner mit einerNennwrmeleistung kleiner als oder gleich 1 000 kWThis European Standard was approved by CEN on 14 December 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipula
13、te the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists
14、in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of
15、 Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FO
16、R STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 303-7:2006: ELicensed Copy: Wang Bin, na, Tue Ap
17、r 03 07:10:06 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEN 303-7:2006 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Constructional and operational requirements9 4.1 General principles9 4.2 Operational requirements .9 5 Test methods18 5.1 General princi
18、ples18 5.2 External tightness of the gas line 21 5.3 Heat input rates21 5.4 Gas pressure governor .22 5.5 Safety of operation 22 5.6 Control and safety equipments25 5.7 Combustion26 5.8 Useful efficiencies .27 5.9 Condensation.34 6 Marking and instructions 34 6.1 Marking .34 6.2 Instructions 36 6.3
19、Presentation .38 Annex A (informative) Diameters of combustion products evacuation ducts marketed in the various countries.49 Annex B (informative) Practical method of calibrating the test rig to enable determination of heat loss Dp.50 Annex C (informative) Determination of the heat losses from the
20、test rig of the indirect method and the contributions of the circulating pump of the test rig (see 5.8.2.3.1.3) .51 Annex D (informative) Determination of the operating time at full rate prior to modulation.52 Annex E (normative) Determination of the combustion characteristics Carbon monoxide and ni
21、trogen oxides 53 Annex F (normative) Case of a forced draught burner complying with EN 67655 Annex G (informative) Main symbols and abbreviations used.56 Annex H (informative) A-deviations.57 Annex ZA (informative) Clauses of this European Standard addressing essential requirements or other provisio
22、ns of EU Directives58 Bibliography 61 National Annex NA (informative) Additional information for UK users 62Licensed Copy: Wang Bin, na, Tue Apr 03 07:10:06 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEN 303-7:2006 (E) 3 Foreword This document (EN 303-7:2006) has been prepared by Technical Committee C
23、EN/TC 109 “Central heating boilers using gaseous fuels”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2007, and conflicting national standards sha
24、ll be withdrawn at the latest by April 2007. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN30372006HEATINGBOILERSPART7GASFIREDCENTRALHEATINGBOILERSNEQUIPPEDWITHAFORCEDDRAUGHTBURNEROFNOMINALHEATOUTPUTNOTEXCEEDING1000KW

链接地址:http://www.mydoc123.com/p-550403.html