1、BRITISH STANDARDBS EN 1434-1:2007Heat meters Part 1: General requirementsThe European Standard EN 1434-1:2007 has the status of a British StandardICS 17.200.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g
2、55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Wed Sep 05 07:43:23 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 1434-1:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2007 BSI 2007ISBN 97
3、8 0 580 50847 9National forewordThis British Standard was published by BSI. It is the UK implementation of EN 1434-1:2007. It supersedes BS EN 1434-1:1997 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee CPI/30, Measurement of fluid flow in closed condu
4、its, to Subcommittee CPI/30/7, Volume flow-rate methods.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Complia
5、nce with a British Standard cannot confer immunity from legal obligations. Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Wed Sep 05 07:43:23 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 1434-1February 2007ICS 17.2
6、00.10 Supersedes EN 1434-1:1997 English VersionHeat meters - Part 1: General requirementsCompteurs dnergie thermique - Partie 1: PrescriptionsgnralesWrmezhler - Teil 1: Allgemeine AnforderungenThis European Standard was approved by CEN on 7 January 2007.CEN members are bound to comply with the CEN/C
7、ENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to an
8、y CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN
9、 members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Swede
10、n, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref.
11、No. EN 1434-1:2007: ELicensed Copy: Wang Bin, na, Wed Sep 05 07:43:23 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEN 1434-1:2007 (E) 2 Contents Page Foreword4 1 Scope 5 2 Normative references 5 3 Types of instrument.5 3.1 General5 3.2 Complete instrument.5 3.3 Combined instrument5 3.4 Hybrid instrumen
12、t (often called a “compact“ instrument) 5 3.5 Sub-assemblies of a heat meter, which is a combined instrument5 3.5.1 General5 3.5.2 Flow sensor6 3.5.3 Temperature sensor pair.6 3.5.4 Calculator .6 3.6 Equipment under test (EUT) .6 4 Terms, definitions and symbols.6 5 Rated operating conditions 9 5.1
13、Limits of temperature range .9 5.2 Limits of temperature differences9 5.3 Limits of flow-rate9 5.4 Limit of thermal power 9 5.5 Maximum admissible working pressure; PS 9 5.6 Nominal pressure; PN .10 5.7 Limits in ambient temperature .10 5.8 Limits in deviations in supply voltage.10 5.9 Maximum press
14、ure loss10 6 Technical characteristics10 6.1 Materials and construction.10 6.2 Requirements outside the limiting values of the flow rate10 6.3 Display 11 6.4 Protection against fraud .11 6.5 Supply voltage .11 6.6 Qualifying immersion depth of a temperature sensor.12 6.7 The influence on a temperatu
15、re sensor pair caused by mounting in pockets12 6.8 Reproducibility.12 6.9 Repeatability.12 6.10 Software12 7 Specified working range .13 7.1 General13 7.2 Temperature difference.13 7.3 Flow rate .13 8 Heat transmission formula .13 9 Metrological characteristics (Maximum Permissible Error, MPE)14 9.1
16、 General14 9.2 Values of maximum permissible errors 14 9.2.1 Maximum permissible relative errors of complete heat meters .14 9.2.2 Maximum permissible relative error of sub-assemblies .15 9.3 Application of maximum permissible errors 15 Licensed Copy: Wang Bin, na, Wed Sep 05 07:43:23 GMT+00:00 2007
17、, Uncontrolled Copy, (c) BSIEN 1434-1:2007 (E) 3 10 Environmental classification15 10.1 General .15 10.2 Environmental class A (Domestic use, indoor installations)15 10.3 Environmental class B (Domestic use, outdoor installations) .16 10.4 Environmental class C (Industrial installations) 16 11 Heat
18、meter specification.16 11.1 General .16 11.2 Flow sensor16 11.3 Temperature sensor pair 17 11.4 Calculator .18 11.5 Complete meters .19 12 Information to be delivered with the meter or sub-assemblies20 Annex A (normative) Heat coefficient equations.22 Annex B (normative) Flow conditioner package .24
19、 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 2004/22/EC, MID .26 Bibliography27 Licensed Copy: Wang Bin, na, Wed Sep 05 07:43:23 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEN 1434-1:2007 (E) 4 Foreword This document (EN 1434-1:2007
20、) has been prepared by Technical Committee CEN/TC 176 “Heat meters”, the secretariat of which is held by DS. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2007, and conflicting national s
21、tandards shall be withdrawn at the latest by August 2007. This document supersedes EN 1434-1:1997. The other parts are: Part 2 - Constructional requirements Part 3 - Data exchange and interfaces Part 4 - Pattern approval tests Part 5 - Initial verification tests Part 6 - Installation, commissioning,
22、 operational monitoring and maintenance According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Gr
23、eece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: Wang Bin, na, Wed Sep 05 07:43:23 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEN 1434-1:2007 (
24、E) 5 1 Scope This European Standard specifies the general requirements and applies to heat meters, that is to instruments intended for measuring the heat which, in a heat-exchange circuit, is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The heat meter indica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN143412007HEATMETERSGENERALREQUIREMENTS 量热计 一般 要求 PDF

链接地址:http://www.mydoc123.com/p-549000.html