《BS DD ENV 1401-3-2001 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinylchloride) (PVC-U) - Guidance for installation《非承压地下排放和污水用.pdf》由会员分享,可在线阅读,更多相关《BS DD ENV 1401-3-2001 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinylchloride) (PVC-U) - Guidance for installation《非承压地下排放和污水用.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、DRAFT FOR DEVELOPMENT DD ENV 1401-3:2001 Plastic piping systems for non pressure underground drainage and sewerage Unplasticized poly (vinyl chloride) (PVC-U) Part 3: Guidance for installation ICS 23.040.20; 83.140.30; 91.140.80; 93.030 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRI
2、GHT LAWDD ENV 1401-3:2001 This Draft for Development, having been prepared under the direction of the Sector Committee for Materials and Chemicals, was published under the authority of the Standards Committee and comes into effect on 15 August 2001 BSI 07-2001 ISBN 0 580 38151 x National foreword Th
3、is Draft for Development is the English language version of ENV 1401-3:2000. This publication is not to be regarded as a British Standard. It is being issued in the Draft for Development series of publications and is of a provisional nature because it is specifically intended to give guidance for th
4、e installation of piping systems made from components conforming to BS EN 1401-1, hence for the purpose of installing such PVC-U piping systems for gravity drains and sewers this document provides for consideration an alternative document to BS 5955-6:1980, which remains a prime national standards f
5、or this purpose. It should be applied on this provisional basis, so that information and experience of its practical application may be obtained. Please note BS EN 1401-1:1998 superseded BS 5481:1977 and partially superseded BS 4660:1989. Products conforming to BS 4660:2000 and BS 7158:2001 have bee
6、n designed to provide access to drainage systems constructed from components conforming to EN 1401-1. Comments arising from the use if this Draft for Development are requested so that UK experience can be reported to the European organization responsible for its conversion into a European Standard.
7、A review of this publication will be initiated 2 years after its publication by the European organization so that a decision can be taken on its status at the end of its three-year life. The commencement of the review period will be notified by an announcement in Update Standards. According to the r
8、eplies received by the end of the review period, the responsible BSI Committee will decide whether to support the conversion into a European Standard, to extend the life of the prestandard or to withdraw it. Comments should be sent in writing to the Secretary of BSI SubCommittee PRI/88/1, Plastic Pi
9、ping for Non Pressure, at 389 Chiswick High Road, London W4 4AL, giving the document reference and clause number and proposing, where possible, an appropriate revision of the text. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The
10、 British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. Sum
11、mary of pages This document comprises a front cover, an inside front cover, the ENV title page, pages 2 to 8, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date Commen
12、tsEUROPEANPRESTANDARD PRNORMEEUROPENNE EUROPISCHEVORNORM ENV14013 May2001 ICS23.040.01 Englishversion Plasticspipingsystemsfornonpressureundergrounddrainage andsewerageUnplasticizedpoly(vinylchloride)(PVCU)Part 3:Guidanceforinstallation Systmesdecanalisationsenplastiquepourles branchementsetlescolle
13、cteursdassainissemententerrs sanspressionPoly(chloruredevinyle)nonplastifi(PVC U)Partie3:Guidepourlapose KunststoffRohrleitungssystemefrerdverlegtedrucklose AbwasserkanleundleitungenWeichmacherfreies Polyvinylchlorid(PVCU)Teil3:Empfehlungenfrdie Verlegung ThisEuropeanPrestandard(ENV)wasapprovedbyCEN
14、on23March2001asaprospectivestandardforprovisionalapplication. TheperiodofvalidityofthisENVislimitedinitiallytothreeyears.AftertwoyearsthemembersofCENwillberequestedto submittheir comments,particularlyonthequestionwhethertheENVcanbeconvertedintoaEuropeanStandard. CENmembersarerequiredtoannouncetheexi
15、stenceofthisENVinthesamewayasforanENandtomaketheENVavailablepromp tly atnationallevelinanappropriateform.Itispermissibletokeepconflictingnationalstandardsinforce(inparalleltothe ENV)untilthefinal decisionaboutthepossibleconversionoftheENVintoanENisreached. CENmembersarethenationalstandardsbodiesofAu
16、stria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Iceland,Ireland,Italy,Luxembourg,Netherlands,Norway,Portugal,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050
17、Brussels 2001CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.ENV14013:2001EPage2 ENV14013:2001 Contents Page Foreword 3 1 Scope4 2 Normativereferences4 3 Choiceofstiffness(SN)series4 3.1 General4 3.2 Pipes4 3.3 Fittings .5 3.4 ApplicationareacodeD. 5
18、4 Storageinsunlight 5 5 Handlingandinstallationatlowtemperature.6 6 Pushfitjoints(elastomericsealings)6 7 Solventcementjoints .6 8 Maximumdeviationfromstraightness6 9 Connectiontorigidstructures.7 10 Repairs7 11 Connectiontoexistingpipes .8 12 Testingonsite .8Page3 ENV14013:2001 Foreword ThisEuropea
19、nPrestandardhasbeenpreparedbyTechnicalCommitteeCEN/TC155“Plasticspiping systemsandductingsystems“,thesecretariatofwhichisheldbyNEN. ThisPrestandardisaPartofaSystemStandardforplasticspipingsystemsofaparticularmaterialfor aspecifiedapplication.ThereisanumberofsuchSystemStandards. SystemStandardsarebas
20、edontheresultsoftheworkundertakeninISO/TC138“Plasticspipes, fittingsandvalvesforthetransportoffluids“,whichisaTechnicalCommitteeoftheInternational OrganizationforStandardization(ISO). Theyaresupportedbyseparatestandardsontestmethodstowhichreferencesaremadethroughout theSystemStandard. TheSystemStand
21、ardsareconsistentwithgeneralstandardsonfunctionalrequirementsandon recommendedpracticeforinstallation. EN1401consistsofthefollowingParts,underthegeneraltitle Plasticspipingsystemsfor nonpressureundergrounddrainageandsewerageUnplasticizedpoly(vinylchloride)(PVCU) Part1: Specificationsforpipes,fitting
22、sandthesystem Part2: Guidanceforassessmentofconformity(ENV) Part3: Guidanceforinstallation(thisprestandard) AccordingtotheCEN/CENELECInternalRegulations,thenationalstandardsorganizationsofthe followingcountriesareboundtoannouncethisEuropeanPrestandard:Austria,Belgium,Czech Republic,Denmark,Finland,F
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSDDENV140132001PLASTICSPIPINGSYSTEMSFORNONPRESSUREUNDERGROUNDDRAINAGEANDSEWERAGEUNPLASTICIZEDPOLYVINYLCHLORIDEPVCUGUIDANCEFORINSTALLATION

链接地址:http://www.mydoc123.com/p-548261.html