BS 8747-2007 Reinforced bitumen membranes (RBMs) for roofing - Guide to selection and specification《屋面用增强沥青薄膜材料(RBMs) 筛选和规格指南》.pdf
《BS 8747-2007 Reinforced bitumen membranes (RBMs) for roofing - Guide to selection and specification《屋面用增强沥青薄膜材料(RBMs) 筛选和规格指南》.pdf》由会员分享,可在线阅读,更多相关《BS 8747-2007 Reinforced bitumen membranes (RBMs) for roofing - Guide to selection and specification《屋面用增强沥青薄膜材料(RBMs) 筛选和规格指南》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、BS 8747:2007Reinforced bitumen membranes (RBMs) for roofing Guide to selection and specificationICS 91.060.20NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDPublishing and copyright informationThe BSI copyright notice displayed in this document indicates when th
2、e document was last issued. BSI 2007ISBN 978 0 580 50900 1The following BSI references relate to the work on this standard:Committee reference B/546/1Draft for comment 06/30058801 DCPublication historyFirst published June 2007Amendments issued since publicationAmd. no. Date Text affectedBS 8747:2007
3、 BSI 2007 iBS 8747:2007ContentsForeword iiIntroduction CEN test methods referenced in this standard 11 Scope 12 Normative references 23 Terms and definitions 24 Membrane selection guidelines 55 System selection 166 Bonding and installation of an RBM 18AnnexesAnnex A (informative) CE marking informat
4、ion for an RBM product 20Annex B (informative) Guide to specifying RBM equivalent to Type 1F or Type 5U reinforced bitumen roofing underlay 21Annex C (informative) Guide to specifying RBM equivalent to Type 3G glass-fibre reinforced bitumen perforated venting layer 23Annex D (informative) Worked exa
5、mples 24Bibliography 32List of tablesTable 1 Tensile strength of membrane classes 12Table 2 Resistance to impact 12Table 3 Resistance to static loading 12Table 4 Combinations of D subclass and L subclass to give P class 12Table 5 Membrane classification by performance requirement 14Table 6 Compariso
6、n between BS 747 membranes and the SNPN system 15Table 7 Flow chart for system selection Warm deck roofs 16Table 8 Flow chart for system selection Inverted warm roofs 18Table B.1 Mass per units area for constituents of Type 1F and Type 5U RBMs 22Table C.1 Mass per units area for constituents of Type
7、 3G RBMs 24Summary of pagesThis document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 32, an inside back cover and a back cover.BS 8747:2007ii BSI 2007ForewordPublishing informationThis British Standard is published by BSI and came into effect on 29 June 2007. It was pr
8、epared by Subcommittee B/546/1, Reinforced bitumen membranes. A list of organizations represented on this committee can be obtained on request to its secretary.Relationship with other publicationsSome products included within this Standard used to be commonly referred to as roofing “felts”, and were
9、 covered by BS 747:2000. The new European product standard BS EN 13707, which will replace BS 747, refers to these as “flexible bitumen sheets for roof waterproofing”. This could be confusing to the UK construction industry. Therefore, the title of this guide reflects the current terminology used in
10、 the UK and in the Code of Practice, BS 8217. These products are now referred to as “Reinforced Bitumen Membranes (RBMs) for Roofing”.In flat roofing applications, these materials are almost always used with a fully supporting substrate. The exception is on a profiled metal deck, where the top flats
11、 (crowns) of the profile are used for support. General flat roofing design is covered in BS 6229. Specific roof design and installation of these membranes is covered in BS 8217. BS 8747 gives guidance on the selection and use of RBMs, including those specified in BS EN 13707. Guidance in specifying
12、RBMs equivalent to those specified in BS 747:2000 (but not covered by BS EN 13707) is included in Annexes B and C.Publications are also available that give useful advice on construction safety (see Bibliography).Information about this documentThis guide provides “primary advice” to the specifier wit
13、h respect to the production of an effective roof, and is intended as a link document between the material product standard and the final contract specification. This British Standard takes the form of guidance and recommendations. It cannot be quoted as a specification, and claims of compliance to i
14、t cannot be made. NOTE It has been assumed in the drafting of this guide that the design and construction of flat roofs is entrusted to appropriately qualified and competent people. It has also been assumed that the building owner will adopt the recommendations in respect of planned inspection and m
15、aintenance of a roof during service.Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. BSI 200
16、7 1BS 8747:2007Introduction CEN test methods referenced in this standardThe overall aim of the Construction Products Directive (CPD) 1 is to reduce barriers to trade throughout the European Economic Area. The CPD has, as an ideal, the concept of performance related test methods. The relationship bet
17、ween the results of test methods and the performance on a roof for reinforced bitumen membranes (RBMs) has not been proven, thus it should not be assumed that the results of such tests indicate accurately the in-service performance of the membrane(s) tested. The test methods in BS EN 13707 have been
18、 developed in response to product characteristics identified from the Building Regulations 2 or their counterparts in the various Member States. Some of these are required only for installation of the product. The CEN test methods and product standards have been developed by a committee of experts f
19、rom Member States. These test methods were based on current standards such as ISOs where possible but in most cases the scope of existing standards did not coincide entirely with the scope of the CEN standards. Roof waterproofing is an example of this. Most of the test methods are therefore new and
20、there is no history of past values to rely upon for a given product. CEN product standards also stipulate whether the manufacturer declares a value for a given test method, together with a declared tolerance, or states a manufacturers limiting value. BS 747:2000 was a recipe standard. As such it was
21、 known in the roofing industry that rag-based bitumen felts did not perform as well as polyester-based products. Because of this, it was easy for a specifier to use a BS 747:2000 Type 3 for say garages or sheds, and BS 747:2000 Type 5 for roofs over offices and computer installations.This will not b
22、e possible with BS EN 13707, because it gives no indication as to what values, as a result of carrying out tests, are required or appropriate for given end uses.This committee has selected, through expert knowledge and a limited amount of testing, those test methods which it is believed are most sui
23、table and relevant to performance on a roof, and has assigned threshold values which can be used to conveniently group the products into bands of performance. The worked examples are also based upon industry knowledge and experience. Table 5 correlates end use and substrate with membrane type and ch
24、oice. 1 ScopeThis British Standard gives guidance to assist the selection and specification of a system of appropriate layer(s) of reinforced bitumen membrane (RBM) for each flat and/or sloping roofing project, tailored to the particular requirements of that project.It provides a grouping system to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS87472007REINFORCEDBITUMENMEMBRANESRBMSFORROOFINGGUIDETOSELECTIONANDSPECIFICATION 屋面 增强 沥青 薄膜 材料 RBMS

链接地址:http://www.mydoc123.com/p-547551.html