《BS 8489-4-2016 Fixed fire protection systems Industrial and commercial watermist systems Part 4 Fire performance tests and requirements for watermist systems for local applications.pdf》由会员分享,可在线阅读,更多相关《BS 8489-4-2016 Fixed fire protection systems Industrial and commercial watermist systems Part 4 Fire performance tests and requirements for watermist systems for local applications.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、BS 8489-4:2016Fixed fire protectionsystems Industrial andcommercial watermistsystemsPart 4: Fire performance tests andrequirements for watermist systemsfor local applications involvingflammable liquid firesBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Publishing an
2、d copyright informationThe BSI copyright notice displayed in this document indicates when the documentwas last issued. The British Standards Institution 2016Published by BSI Standards Limited 2016ISBN 978 0 580 85529 0ICS 13.220.20The following BSI references relate to the work on this document:Comm
3、ittee reference FSH/18/5Draft for comment 14/30295816 DCPublication historyFirst published as DD 8489-4, February 2011First published as BS 8489-4, May 2016Amendments issued since publicationDate Text affectedBS 8489-4:2016 BRITISH STANDARDContentsForeword ii1 Scope 12 Normative references 13 Terms
4、and definitions 14 Principle 15 Square pool fire 16 Channel diesel pool fire 77 Heptane spray fire 98 Diesel pool fire, 2m2msquare, combined with a 5.8 MW diesel sprayfire 129 Obstructed3m3msquare diesel pool fire 1910 Offset1m1msquare diesel pool fire 2111 Diesel pool fire, 2m2msquare, combined wit
5、h a 5.8 MW diesel sprayfire, with an external ignition source 22Bibliography 24List of figuresFigure 1 Configuration for square diesel pool 3Figure 2 Configuration for channel diesel pool 8Figure 3 Configuration for heptane spray fire 10Figure 4 Configuration for pool/spray fire arrangements in 8.1.
6、1.4a) 14Figure 5 Configuration for pool/spray fire arrangements in 8.1.1.4b) 15Figure 6 Configuration for pool/spray fire arrangements in 8.1.1.4c) 16Figure 7 Configuration for pool/spray fire arrangements in 8.1.1.4d) 17Figure 8 Configuration for pool/spray fire arrangements in 8.1.1.4e) 18Figure 9
7、 Configuration for square diesel pool with obstruction 20Figure 10 Configuration for pool/spray fire with an external ignitionsource 23List of tablesTable 1 Characteristics of oil burners for tests involving spray fires 9Summary of pagesThis document comprises a front cover, an inside front cover, p
8、ages i to iv,pages 1 to 24, an inside back cover and a back cover.BRITISH STANDARD BS 8489-4:2016 The British Standards Institution 2016 iForewordPublishing informationThis part of BS 8489 is published by BSI Standards Limited, under licence fromThe British Standards Institution, and came into effec
9、t on 31 May 2016. It wasprepared by Subcommittee FSH/18/5, Watermist systems, under the authority ofTechnical Committee FSH/18, Fixed fire fighting systems. A list of organizationsrepresented on these committees can be obtained on request to their secretary.SupersessionThis part of BS 8489 supersede
10、s DD 8489-4:2011, which is withdrawn.Relationship with other publicationsBS 8489 is published in a series of parts: Part 1: Code of practice for design and installation; Part 4: Tests and requirements for watermist systems for local applicationsinvolving flammable liquid fires; Part 5: Tests and req
11、uirements for watermist systems for the protection ofcombustion turbines and machinery spaces with volumes up to andincluding 80 m3; Part 6: Tests and requirements for watermist systems for the protection ofindustrial oil cookers; Part 7: Tests and requirements for watermist systems for the protecti
12、on oflow hazard occupancies.BS 8489-4 is intended to be read in conjunction with BS 8489-1.Information about this documentThis document converts DD 8489-4 into a full British Standard.Third-party testing/certification. Users of this British Standard are advised toconsider the desirability of third-p
13、arty testing/certification of conformity withthis British Standard.Use of this documentThis British Standard is intended for use by manufacturers, designers andinstallers of watermist systems, and for authorities having jurisdiction.It has been assumed in the preparation of this British Standard tha
14、t theexecution of its provisions will be entrusted to appropriately qualified andexperienced people, for whose use it has been produced.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type.Its methods are expressed as a set of instructions, a descripti
15、on, or in sentencesin which the principal auxiliary verb is “shall”. Its requirements are expressed insentences in which the principal auxiliary verb is “shall”.Commentary, explanation and general informative material is presented insmaller italic type, and does not constitute a normative element.Wh
16、ere words have alternative spellings, the preferred spelling of the ShorterOxford English Dictionary is used (e.g. “organization” rather than“organisation”).BRITISH STANDARDBS 8489-4:2016ii The British Standards Institution 2016Contractual and legal considerationsThis publication does not purport to
17、 include all the necessary provisions of acontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legalobligations.BRITISH STANDARD BS 8489-4:2016 The British Standards Institution 2016 iiiBRITISH STANDARDBS 8489-4:2016This page deli
18、berately left blankiv The British Standards Institution 20161 ScopeThis part of BS 8489 describes tests and specifies requirements for industrial andcommercial watermist systems for local applications involving flammable liquidfires.The tests specified in this part of BS 8489 are applicable to the f
19、ollowingapplications:a) flammable liquid pool fires where the liquid release can be confined to abunded area, where the entire surface of the bunded area is protected bythe watermist system;b) flammable liquid channel fires in channels not exceeding the watermistsystem manufacturers maximum specifie
20、d width and with no limit tochannel length;c) partially obstructed flammable liquid pool fires where the percentage ofobstructed surface is limited to that tested;d) spray fires up to 6 MW fuelled by flammable liquids;e) spray and pool fire combinations where confined to a bunded area;f) flammable l
21、iquid residues (ink and paper dust) on printing presses.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in thisdocument and are indispensable for its application. For dated references, onlythe edition cited applies. For undated references, the latest ed
22、ition of thereferenced document (including any amendments) applies.BS 8489-1, Fixed fire protection systems Industrial and commercial watermistsystems Part 1: Code of practice for design and installationBS EN ISO/IEC 17025:2005, General requirements for the competence of testingand calibration labor
23、atories3 Terms and definitionsFor the purposes of this part of BS 8489, the terms and definitions givenin BS 8489-1 apply.4 PrincipleThe local application fire performance tests involving flammable liquidscomprise: open, obstructed and offset pool fires; spray fires; and combined pooland spray fires
24、, utilizing both heptane and diesel fuels. The watermist systemneeds to pass all tests.5 Square pool fire5.1 Test5.1.1 ApparatusNOTE Unless otherwise stated, the following tolerances apply: length: 2%; volume: 5%;BRITISH STANDARD BS 8489-4:2016 The British Standards Institution 2016 1 pressure: 3%;
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS848942016FIXEDFIREPROTECTIONSYSTEMSINDUSTRIALANDCOMMERCIALWATERMISTSYSTEMSPART4FIREPERFORMANCETESTSANDREQUIREMENTSFORWATERMISTSYSTEMSFORLOCALAPPLICATIONSPDF

链接地址:http://www.mydoc123.com/p-547423.html